Home Companies Dewei Medical Equipment Co., Ltd

Hematology Analyzer Reagent for DIRUI BCC-3600 Diluent Rinse Lyse Cell Counter

Dewei Medical Equipment Co., Ltd

Contact Us

Trade Verify

Address: B318 Building B, Western Silicon Valley, Bao'an District, Shenzhen, China

Contact name:Sherry Cai

Inquir Now

Dewei Medical Equipment Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Hematology Analyzer Reagent for DIRUI BCC-3600 Diluent Rinse Lyse Cell Counter

City & Province shenzhen
Categories Camera Chargers
InquireNow

Product Details

Hematology Analyzer Reagent for DIRUI BCC-3600 Diluent Rinse Lyse Cell Counter

 

Intended Use of Dirui CBC Reagents
To be used for blood cell counting, sizing, and WBC differentiation, hemoglobin determination on DIRUI BCC-3600 Hematology Analyzers.

 

Specification of Dirui CBC Reagents

Compatible Reagents on Dirui BCC-3600 BCC-3000B 
Cat. NoDescriptionPack Size
DWX-31106DILUENT-BCC20L
DWX-31107LYSE-BCC500ml
DWX-31108RINSE-BCC500ml

 

 

Limitation of Dirui CBC Reagents

If the temperature of the reagent is out of the specified range, the specimen's measurement parameters may appear abnormal. If in this condition, please confirm the measurement parameters with the microscopy method. Please refer to the instrument operation manual for details.

 

Storage of Dirui CBC Reagents

The product should be stored in 2℃-35℃ and the storage period is 2 years. After opening the bottle, it is used in 15℃-30℃, and the validity period is 60 days.

 

Attention of Dirui CBC Reagents

1. This product is an in vitro diagnostic reagent;

2. Pay attention to seal and prevent pollution;

3. Read the instructions carefully before use, and should stop using them when they exceed the period of validity;

4. If the product freezes, it should be completely defrosted at room temperature and used after mixing.

5. Waste liquid, waste, residual products and treatment of contaminated packaging materials, please comply with local regulations;

6. It is strictly forbidden to eat and avoid contact with eyes and skin. Once Contact your eyes and skin,please clean immediately with plenty of water and seek medical advice.

 

Does the blood cell counter need to use products for calibration and quality control?

Calibration products are required in the following situations:

1. New instrument

2. After a major maintenance

3.The results of the quality control are not controllable.

4. The manufacturer recommends that the instrument be tested every six months or three months to ensure the accuracy of the instrument.

Quality control needs to be done once or twice a day.

 

Hot Products

Hematology Analyzer Reagent for Abbott CD1800 CD1700 CD1600 CD1400 CD1300 3 Part Intended Use To be ...
Hematology Analyzer Reagent for Medonic CA570 CBC 3 Part Analyzer Diluent Lyse Clean Intended Use of ...
Hematology Analyzer Reagent for RAYTO RT-7200 RT-7300 RT-7600 Diluent Lyse Rinse 3 Part Cell Counter ...
Hematology Analyzer Reagent for DIRUI BCC-3600 Diluent Rinse Lyse Cell Counter Intended Use of Dirui ...
Hematology Analyzer Reagent for RAYTO HEMARAY 5 Part Hemaray 83 Diluent Lyse Clean Intended Use of ...
Hematology Analyzer Reagent for GENRUI GENIUS KT6400 KT6380 KT6300 KT6280 KT6200 KT6180 3 Part ...