Qualitative Detection Syphilis Rapid Test Kit For Whole Blood Serum Plasma

City & Province shenzhen
InquireNow

Product Details

Syphilis Rapid Test Device Whole Blood Serum Plasma Rapid Test Strip Kit

INTENDED USE

The Syphilis Rapid Test Device (Whole Blood/Serum/Plasma) is a rapid visual immunoassay for the qualitative, presumptive detection of IgM and IgG antibodies to Treponema Pallidum (TP) in human Whole Blood, serum or plasma specimens. This kit is intended for use as an aid in the diagnosis of syphilis.

 

INTRODUCTION

Treponema Pallidum (TP), a spirochete bacterium with an outer envelope and a cytoplasmic membrane, is the causative agent of the venereal disease syphilis. Although syphilis rates are declining in the United States after an epidemic between 1986 and 1990, the incidence of syphilis in Europe has increased since 1992, especially in the countries of the Russia Federation, where peaks of 263 cases per 100,000 have been reported. In addition, the positive rate of serological test results for syphilis in HIV-infected individuals has been rising recently.

The serological detection of specific antibodies to TP has been long recognized in the diagnosis of syphilis since the natural course of the infection is characterized by periods without clinical manifestations. The antibody response to TP can be detected within 4 to 7 days after the syphilis chancre appears, allowing early detection and diagnosis of syphilis infection.

A variety of antigens have been used in syphilis serological tests, such as Rapid Plasma Cardiolipin (RPR) or VDRL antigen, TP extracts derived from in vitro culture or inoculated rabbit testes. However, RPR and VDRL antigens are not treponemal specific, and whole TP extracts are not reproducible and contain a certain amount of contaminating materials such as flagella, which may lead to a nonspecific reaction in assays of test serum.

 

MAIN CONTENTS

• One pouch containing a reaction test Cassette with desiccant.

• Disposable pipettes.

• Instructions for use.

 

STORAGE AND STABILITY

• Store at 39~ 86 º F (4 ~ 30 º C) in the sealed pouch for 18 months.

 

PRECAUTIONS

• For in vitro diagnostic use only.

• Do not use after expiration date.

• The test Cassette should remain in the sealed pouch until use.

• The used test Cassette should be discarded according to local regulations.

 

DIRECTION OF USE

Bring tests, specimens, buffer and/or controls to room temperature (1530°C) before use.

1. Remove the test from its sealed pouch, and place it on a clean, level surface. Label the device with patient or control identification. For best results, the assay should be performed within one hour.

2. Using the provided disposable pipette, transfer 3 drops of serum/plasma specimen (approximately 75 µL) to the specimen well (S) of the device and start the timer.

OR

Transfer 2 drop of whole blood specimen (approximately 50 µL) to the specimen well (S) of the device with the provided disposable pipette, then add 1 drop of buffer and start the timer.

OR

Allow 2 hanging drops of fingerstick whole blood specimen to fall into the center of the specimen well (S) on the device, then add 1 drop of buffer and start the timer.

Avoid trapping air bubbles in the specimen well (S), and do not add any solution to the result area.

As the test begins to work, you will see color move across the membrane.

3. Wait for the colored band(s) to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes.

 

INTERPRETATION

POSITIVE: Two colored bands appear on the membrane. One band appears in the control region (C) and another band appears in the test region (T).

NEGATIVE: Only one colored band appears, in the control region (C). No apparent colored band appears in the test region (T).

INVALID: Control band fails to appear. Results from any test which has not produced a control band at the specified read time must be discarded. Please review the procedure and repeat with a new test. If the problem persists, discontinue using the kit immediately and contact your local distributor.

 

 

Hot Products

Test kit is created for the qualitative detection and differentiation of Toxoplasma specific IgG and ...
【INTENDED USE】 The Strep A Rapid Test (Swab) is a rapid visual immunoassay for the qualitative, ...
【INTENDED USE】 The Dengue NS1 & IgG/IgM Rapid Test Combo is a rapid chromatographic immunoassay for ...
Medical Chemistry Analyzer Reagent for XS-1000i XS-800i Diluent Lyse Sysmex Hematology Reagents ...
Sysmex Hematology Reagents of XE-2100 XE-5000 CBC Analyzers Specification of Sysmex CBC Reagents ...
Sysmex Hematology Reaegnts XS Series Analyzer Compatible Reagent Manufacturer What is the CBC ...