Home Companies Dewei Medical Equipment Co., Ltd

CE Rapid Test Combo Kit for Drug Abuse Urine Sample Test MOP MET KET THC AMP

Dewei Medical Equipment Co., Ltd

Contact Us

Trade Verify

Address: B318 Building B, Western Silicon Valley, Bao'an District, Shenzhen, China

Contact name:Sherry Cai

Inquir Now

Dewei Medical Equipment Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

CE Rapid Test Combo Kit for Drug Abuse Urine Sample Test MOP MET KET THC AMP

City & Province shenzhen
Categories Dyestuff Intermediates
InquireNow

Product Details

CE Rapid Test Combo Kit for Drug Abuse Urine Sample Test MOP MET KET THC AMP

 

 

【FEATURES】

Accurate lab grade quality
Easy detedction control line
Quick and accurate result.

 

【INTENDED USE】
2-15 combination of the following drugs:AMP/ BAR/ BUP/ BZO/ COC/ COT/ ETG/ FYL/ K2/ KET/ MAM/ MDMA/MET/ MOP300/ MQL Rapid Multi-Drug 2-15 Test is a rapid, screening test for the qualitative detection of multiple drugs and drug metabolites in human urine at specified cut off levels. For professional use only. For in vitro diagnostic use only.

Drug(Identifier)
Calibrator
Cut-off level
Amphetamine (AMP)
d-Amphetamine
1000ng/mL
Barbiturates (BAR)
Secobarbital
300 ng/mL
Buprenorphine(BUP)
Buprenorphin
10 ng/mL
Benzodiazepines (BZO)
Oxazepam
300 ng/mL
Cocaine (COC)
Benzoylecgonine
300 ng/mL

 

What is cut off level?

The cut-off level is the specified concentration of a substance in a urine samples. Above concentration is a positive result, and vice versa.
Detection time shows how long a urine test can detect cetain substance after a person has taken them.

 

【OPERATION】
Test must be in room temperature (15ºC to 30ºC)
1. Donor collects urine specimen in a urine cup.
2. Open the sealed pouch by tearing along the notch. Remove the test cassette from the pouch and place it on a level surface.
3. Hold the sample dropper vertically, and add exactly three drops of the urine specimen into the sample well.
4. The result should be read at 5 minutes. Do not interpret the result after 10 minutes. See the illustration below.

 

【INTERPRETATION OF RESULTS】
Preliminary positive (+) Only one colored band appears, in the control region (C). No colored band appears in the test region (T).
Negative (-) Two colored bands appear on the membrane. One band appears in the control region (C) and another band appears in the test region (T).
Invalid Control band fails to appear. Results from any test which has not produced a control band at the specified read time must be discarded.
Please review the procedure and repeat with a new test. If the problem persists, discontinue using the kit immediately and contact your local distributor.

 

【CONTENTS】
Drug Test
Desiccant
Leaflet with instruction for use

 

【STORAGE AND STABILITY】
The kit should be stored at 2-30°C until the expiry date printed on the sealed pouch
The test must remain in the sealed pouch until use
Keep away from direct sunlight, moisture and heat
Do not freeze.
Care should be taken to protect the components of the kit from contamination.
Do not use if there is evidence of microbial contamination or precipitation.
Biological contamination of dispensing equipment, containers or reagents can lead to false results.

 

【Manufactured by】
DEWEI MEDICAL EQUIPMENT CO.,LTD
5th floor, No. 4 building, Shiyou Industrial Park, Jun'an , Shunde, Foshan, China 52832

 

Hot Products

Test kit is created for the qualitative detection and differentiation of Toxoplasma specific IgG and ...
【INTENDED USE】 The Dengue NS1 & IgG/IgM Rapid Test Combo is a rapid chromatographic immunoassay for ...
【INTENDED USE】 The Strep A Rapid Test (Swab) is a rapid visual immunoassay for the qualitative, ...
Medical Chemistry Analyzer Reagent for XS-1000i XS-800i Diluent Lyse Sysmex Hematology Reagents ...
Sysmex Hematology Reagents of XE-2100 XE-5000 CBC Analyzers Specification of Sysmex CBC Reagents ...
Sysmex Hematology Reaegnts XS Series Analyzer Compatible Reagent Manufacturer What is the CBC ...