Home Companies Dewei Medical Equipment Co., Ltd

Propoxyphene PPX Rapid Test Kit Abuse DrugRapid Test Cassette For Urine Sample

Dewei Medical Equipment Co., Ltd

Contact Us

Trade Verify

Address: B318 Building B, Western Silicon Valley, Bao'an District, Shenzhen, China

Contact name:Sherry Cai

Inquir Now

Dewei Medical Equipment Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Propoxyphene PPX Rapid Test Kit Abuse DrugRapid Test Cassette For Urine Sample

City & Province shenzhen
Categories Dyestuff Intermediates
InquireNow

Product Details

Propoxyphene (PPX) Rapid Test Kit Drug of Abuse Rapid Test Cassette for Urine Sample

 

Propoxyphene (PPX) Rapid Test is a rapid, screening test for the qualitative detection of Propoxyphene (PPX) and metabolites in human urine at specified cut oflevels.

For professional use only.

For in vitro diagnostic use only.

 

【INTENDED USE】

Propoxyphene (PPX) Rapid Tes is an immuno-chromatographic assay for the qualitative determination of the presence of drugs listed in the table below.

 

Drug(Identifier)CalibratorCut-off level
Propoxyphene(PPX)Propoxyphene300 ng/mL

 

This assay provides only a preliminary analytical test result. Gas Chromatography/Mass spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to Propoxyphene (PPX) of abuse test result, particularly when preliminary positive results are indicated.

 

【SUMMARY】

Propoxyphene is a prescription drug for the relief of pain. Overdose of propoxyphene can have the symptoms including analgesia, stupor, respiratory depression and coma . The half-life of propoxyphene is 8 to 24 hours. Propoxyphene reaches its peak in 1 to 2 hours after oral administration.

 

【PRINCIPLE】

Propoxyphene (PPX) Rapid Test s a competitive immunoassay that is used to screen for the presence of Propoxyphene (PPX) and metabolites in urine. It is chromatographic absorbent device in which, drugs within a urine sample, competitively combined to a limited number of drug monoclonal antibody (mouse) conjugate binding sites.

 

When the test is activated, the urine is absorbed into each test strip by capillary action, mixes with the respective drug monoclonal antibody conjugate, and flows across a pre-coated membrane. When drug within the urine sample is below the detection level of the test, respective drug monoclonal antibody conjugate binds to the respective drug-protein conjugate immobilized in the Test Region (T) of the test strip. This produces a colored Test line in the Test Region (T) of the strip, which, regardless of its intensity, indicates a negative test result.

 

When sample drug levels are at or above the detection level of the test, the free drug in the sample binds to the respective drug monoclonal antibody conjugate, preventing the respective drug monoclonal antibody conjugate from binding to the respective drug-protein conjugate immobilized in the Test Region (T) of the device. This prevents the development of a distinct colored band in the test region, indicating a preliminary positive result.

 

To serve as a procedure control, a colored line will appear at the Control Region (C), of each strip, if the test has been performed properly.

 

【WARNINGS AND PRECAUTIONS】

  • Immunoassay for in vitro diagnostic use only.
  • Do not use after expiration date.
  • The test should remain in the sealed pouch until use.
  • The used test should be discarded according to local regulations.

 

【CONTENTS】

  • Drug Test.
  • Desiccant
  • Leaflet with instruction for use.

 

【STORAGE AND STABILITY】

  • The kit should be stored at 2-30°C until the expiry date printed on the sealed pouch.
  • The test must remain in the sealed pouch until use.
  • Keep away from direct sunlight, moisture and heat.
  • Do not freeze .
  • Care should be taken to protect the components of the kit from contamination. Do not use if there is evidence of microbial contamination or precipitation. Biological contamination of dispensing equipment, containers or reagents can lead to false results.

 

【OPERATION】

Test must be in room temperature ( 15ºC to 30ºC)

  • Donor collects urine specimen in a urine cup.
  • Open the sealed pouch by tearing along the notch. Remove the test from the pouch and place it on a level surface.
  • Hold the sample dropper vertically, and add exactly three drops of the urine specimen into the sample well.
  • The result should be read at 5 minutes. Do not interpret the result after 10 minutes. See the illustration below.

 

【INTERPRETATION OF RESULTS】

Preliminary positive (+)

Only one colored band appears, in the control region (C). No colored band appears in the test region (T).

 

Negative (-)

Two colored bands appear on the membrane. One band appears in the control region (C) and another band appears in the test region (T).

 

Invalid

Control band fails to appear. Results from any test which has not produced a control band at the specified read time must be discarded. Please review the procedure and repeat with a new test. If the problem persists, discontinue using the kit immediately and contact your local distributor.

 

 

 

Hot Products

Test kit is created for the qualitative detection and differentiation of Toxoplasma specific IgG and ...
【INTENDED USE】 The Dengue NS1 & IgG/IgM Rapid Test Combo is a rapid chromatographic immunoassay for ...
【INTENDED USE】 The Strep A Rapid Test (Swab) is a rapid visual immunoassay for the qualitative, ...
Medical Chemistry Analyzer Reagent for XS-1000i XS-800i Diluent Lyse Sysmex Hematology Reagents ...
Sysmex Hematology Reagents of XE-2100 XE-5000 CBC Analyzers Specification of Sysmex CBC Reagents ...
Sysmex Hematology Reaegnts XS Series Analyzer Compatible Reagent Manufacturer What is the CBC ...