Instruction:
Weekly circulation digital programming thermostatwith
LCD screen,which has 6-event everyday.Manual mode and programme
mode could be selec-ted.The thermostat is recommended for control
ofelectric heating devices or on/off valve actuator usedin hydronic
floor heating.
Parameters:
Voltage | 220V/230V |
Power consumption | 2W |
Housing material | Self-extinguishing |
Setting range | 5~90ºC |
Protective housing | IP20 |
Dimension:
![](http://img.everychina.com/nimg/85/05/ad680771a51ca2e77078226c91ae.jpg)
Display:
![](http://img.everychina.com/nimg/63/45/d9069e6f853df9312f304b032211.jpg)
Sensor failure:
E0:Built-in sensor short-circuited or disconnected.
E1:Built-in sensor short-circuited or disconnected.
When shows E0/E1 error,thermostat must be checked till thr
error is eliminated.
Selection:
Model | Current | Application |
SK513 | 3A | Built-in&floor sensor,floor limit sensor weekly programme |
SK523 | 3A | Built-in&floor sensor,floor limit sensor weekly programme,a
potential free output |
SK50 | 16A | Built-in&floor sensor,floor limit sensor weekly programme |
Wiring diagram:
![](http://img.everychina.com/nimg/ab/4f/004a58e38d0727d37592831dbc71.jpg)
More products for you to choose:
![](http://img.everychina.com/nimg/48/17/fd3992357108fbf21bcf5c45ca43.jpg)
FAQ
1.How long will it take for the underfloor heating system to warm
up?
The warm up time of an electric underfloor heating
system will be dictated by the insulation used beneath it and the
output of the system. In general, the better insulated the
sub-floor the faster the system will warm up, with Underfloor
Insulation boards?facilitating a very speedy warm up time of as
little as 15 minutes, and un-insulated concrete floors causing the
slowest warm up time. Using a?200W system?beneath ceramic/stone
tiles provides a faster warm up time than 150W system.
2. Can I turn my heating on the day it is fitted?
If you have installed your heating beneath tile
adhesive, levelling compound or a screed you must allow this to dry
out before turning on your system for the first time. If the system
is turned on too early it will force the moisture out of the
covering which may lead it to crack. We would recommend speaking to
the manufacturer of your flexible tile adhesive, grout or screed to
confirm the drying time required.
3. Does each room require its own thermostat?
We would recommend that each room has its own heating
system controlled by its own thermostat. This will allow for
simpler and more accurate temperature control of each room and will
avoid heating rooms which do not require it.
Install
![](http://img.everychina.com/nimg/74/5a/ae5926c6ea658fc62916b140b011.jpg)
- 1,Open main control panel, with 3.5mm slotted point screwdriver
along the inclined plane until to card depths of 4mm, pry up
slightly to open the card hook
- 2,Connect back panel and power, wire as per wiring diagram, fasten
back panel on cassette with M4 screw
- 3,Connect winding displacement of back panel and upper panel
- 4,Hang up with 30° to 2 hooks, press on the 2 bottom corners, stuck
on the upper shell, installation finished.