Home Companies Nanjing Token Electronics Science&Technology Co., Ltd.

UPS SMPS Closed Loop Hall Effect Current Sensor 2000a Measure Range

Nanjing Token Electronics Science&Technology Co., Ltd.
Active Member

Contact Us

[China] country

Address: NO.80,FEITIAN AVENUE,INDUSTRIAL CLUSTER LUKOU TOWN

Contact name:Suki

Inquir Now

Nanjing Token Electronics Science&Technology Co., Ltd.

UPS SMPS Closed Loop Hall Effect Current Sensor 2000a Measure Range

Country/Region china
Categories Switching Power Supply
InquireNow

Product Details

 

The TBC- AP series current sensor is a closed loop device based on the measuring principle of the hall effect and null balance method, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.

 

Electrical data(Ta=25℃±5℃)

 

Type
 


Parameter

TBC025APTBC50APTBC100APTBC125APTBC200APUnit

Rated input(Ipn)
2550100125200A

Measure range(Ip)
75(±18V,
180Ω)
150(±18V,
80Ω)
300(±18V,
68Ω)
375(±18V,
15Ω)
600(±18V,
10Ω)
A

Turnsratio(Np/Ns)
1:10001:10001:20001:10001:2000 

Coil resister
45.0030.0045.0030.0045.00Ω

Rated output(Is)
25±0.5%50±0.5%50±0.5%125±0.5%100±0.5%mA

Supply voltage
±12~±18V
Power consumption20+IpX(Np/Ns)mA

offset current
@Ip=0 ≤±0.2mA

Offset current drift
@ -40~+85℃ ≤±0.5mA
Linearity@Ip=0-±Ipn ≤0.1%FS

Bandwidth
@ -3dB 0~200KHz

Response time
@100A/μS,10%-90% ≤1µs

Galvanic isolation
@ 50HZ,1min 3.0KV

 

Applications

 

AC variable speed drives and servo motor drives

Static converters for DC motor drives

Variable speed drives

Power supplies for welding applications

Battery supplied applications

Uninterruptible Power Supplies (UPS)

Switched Mode Power Supplies(SMPS)

Mechanical dimension(for reference only)

Remarks:

1. All dimensions are in mm.

2. General tolerance ±1mm.

Directions for use

When measure current flows according to the direction of the arrowhead, Output terminal gets the same phase current.

The primary conductor should be≤120℃.

The dynamic performance (di/dt and the response time) is the best when the primary hole is fully filled with

the bus bar.

The primary turns should be at the top of the sensor for the best magnetic coupling.

When the current will be measured goes through a sensor, the voltage will be measured at the output end.

(Note: The false wiring may result in the damage of the sensor)

Custom design in the different rated input current and the output current are available.

 

 

Standards

 

  • UL94-V0.
  • EN60947-1:2004
  • IEC60950-1:2001
  • EN50178:1998
  • SJ 20790-2000

 

General date

 

 ValueUnitSymbol
Operating temperature-40 to +85ºCTA
Storage temperature-40 to+125ºCTS
Mass(approx)25gM

 

Characteristics chart

 

Pulse current signal response characteristic Effects of impulse noise

 

Hot Products

Dismountable Hall Effect Current Transformer Measure DC AC Pulse Current TKC-K series dismountable ...
Blue Hall Effect Current Sensor Transducer , Hall Effect Dc Current Transducer The TKC-BSR565 series ...
100-2000A Open Loop Hall Effect Current Sensor with ±1% Accuracy TKC-BHS5 Series high precision ...
50-200A Hall Effect Current Sensor Transducer For Frequency Converter Characteristics chart The TKC...
20-500A Hall Effect Current Sensor Transducer Programming Type Characteristics chart The TKC-TG3 ...
Programming hall sensor TKC-TF512 maily used in BMS of electric vehicle TKC-TF512 series is a kind ...