Split Core Current Transformer Hall Effect Based Current Sensor PCB Mounting

 

The TBC- Eseries current sensor is a closed loop device based on the measuring principle of the hall effect and null balance method, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.

 

Electrical data(Ta=25℃±5℃)

 

Type

Parameter
TBC50ETBC75ETBC100ETBC200ETBC300E

 

Unit


Rated input (Ipn)
5075100200300A

Measure range(Ip)
120200250450500A

Turns ratio(Np/Ns)
1:10001:15001:10001:20001:3000T

Internal measuring resister
80±0.1%80±0.1%40±0.1%40±0.1%40±0.1%Ω

Rated output
@Ip=±Ipn ±4±0.5%V

Supply voltage
±15 ±5%V
Power consumption≤20+IpX(Np/Ns)mA

Zero offset voltage
@Ip=0 ≤±10mV

Offset drift
@ -40~+85℃ ≤±0.5mV/℃

output drift
@ -40~+85℃ ≤±0.5mV/℃

Linearity
@Ip=0-±Ipn ≤0.1%FS

Response time
@100A/μS,10%-90% ≤1μS

Bandwidth
@ -3db DC~100KHZ

Galvanic isolation
@ 50HZ,AC,1min 3KV

 

 

Applications

Variable speed drives

Welding machine

Battery supplied applications

Uninterruptible Power Supplies (UPS)

Electrochemical

 

Mechanical dimension(for reference only)

 

Remarks:

1. All dimensions are in mm.

2. General tolerance ±1mm.

 

Directions for use

Is will be in a forward direction when the Ip flows according to the direction of the arrowhead.

The primary conductor should be≤120℃.

The dynamic performance (di/dt and the response time)is the best when the primary hole is fully filled with

the bus bar.

The primary turns should be at the top of the sensor for the best magnetic coupling.

When the current will be measured goes through a sensor, the voltage will be measured at the output end.

(Note: The false wiring may result in the damage of the sensor).

Custom design in the different rated input current and the output voltage are available.

 

 

Standards

 

  • UL94-V0.
  • EN60947-1:2004
  • IEC60950-1:2001
  • EN50178:1998
  • SJ 20790-2000

 

General date

 

 ValueUnitSymbol
Operating temperature-40 to +85ºCTA
Storage temperature-40 to +125ºCTS
Mass(approx)44gM

 

Characteristics chart

 

Pulse current signal response characteristic Effects of impulse noise

Hot Products

50-200A Hall Effect Current Sensor Transducer For Frequency Converter Characteristics chart The TKC...
20-500A Hall Effect Current Sensor Transducer Programming Type Characteristics chart The TKC-TG3 ...
Programming hall sensor TKC-TF512 maily used in BMS of electric vehicle TKC-TF512 series is a kind ...
Wide Range Measurement 4800A Hall Effect sensor for inveter use TKC-GT1540 TKC-GT1540 series is a ...
1000-20000A Open Loop Hall Effect Current Sensor For Frequency Converter Applications Variable speed ...
High Precision Open Loop Hall Effect Current Sensor TKC-EKA Series Dismountable Open Loop Hall ...