Home Companies Nanjing Token Electronics Science&Technology Co., Ltd.

DC AC Closed Loop Hall Effect Current Sensor TBC-ES565 Series

Nanjing Token Electronics Science&Technology Co., Ltd.
Active Member

Contact Us

[China] country

Address: NO.80,FEITIAN AVENUE,INDUSTRIAL CLUSTER LUKOU TOWN

Contact name:Suki

Inquir Now

Nanjing Token Electronics Science&Technology Co., Ltd.

DC AC Closed Loop Hall Effect Current Sensor TBC-ES565 Series

Country/Region china
InquireNow

Product Details

DC AC Closed Loop Hall Effect Current Sensor TBC-ES565 Series

 

TBC-ES565 Series current sensor is a closed loop device based on the measuring principle of the hall effect and null balance method ,with a galvanic isolation between primary and secondary circuit, the size of primary not affect test precision, no matter the location of primary in the hole of current sensor, It really measuring resolution 1000:1 and it uses for precision measurement of DC, AC and pulse current.

 

Electrical data(Ta=25℃±5℃)

 

Type

Parameter
TBC10ES565TBC25ES565TBC50ES565TBC75ES565TBC100ES565Unit

Rated input (Ipn)
10255075100A

Measure range(Ip)
3280150225300A
Turns ratio(Np/Ns)1:9601:12001:12001:12001:1200 

 

Internal measuring

resistance

15±0.1%7.5±0.1%3.75±0.1%2.5±0.1%1.875±0.1%Ω
Rated output@Ip=±Ipn ±0.625±0.3%V
Supply voltage+5±2%V
Power consumption≤20+IpX(Np/Ns)mA
Reference voltage+2.5±0.4%V

Zero voltage
@Ip=0 +2.5±0.4%FSV
Offset drift@ -40℃~105℃ ≤±0.05mV/℃

output drift
@ -40℃~105℃ ≤±0.05mV/℃
Linearity@Ip=0-±Ipn ≤0.1%FS
Bandwidth@ -3db 0~200KHz

Response time
@100A/μS,10%-90% <0.5µs

Galvanic isolation
@ 50HZ,AC,1min 3KV

 

Applications

 

Variable speed drives

Welding machine

Battery supplied applications

Uninterruptible Power Supplies (UPS)

Electrochemical

 

Mechanical dimension(for reference only)

 

Remarks:

1. All dimensions are in mm.

2. General tolerance ±1mm

 

Directions for use

 

Is will be in a forward direction when the Ip flows according to the direction of the arrowhead.

The primary conductor should be≤120℃.

The dynamic performance (di/dt and the response time) is the best when the primary hole is fully filled with the bus bar.

The primary turns should be at the top of the sensor for the best magnetic coupling.

When the current will be measured goes through a sensor, the voltage will be measured at the output end.

(Note: The false wiring may result in the damage of the sensor)

Custom design in the different rated input current and the output voltage are available.

 

 

Standards

 

  • UL94-V0.
  • EN60947-1:2004
  • IEC60950-1:2001
  • EN50178:1998
  • SJ 20790-2000

 

General date

 

 ValueUnitSymbol
Operating temperature-40 to +105ºCTA
Storage temperature-40 to +125ºCTS
Mass(approx)15gM

 

Characteristics chart

 

Pulse current signal response characteristic Effects of impulse noise

Hot Products

50-200A Hall Effect Current Sensor Transducer For Frequency Converter Characteristics chart The TKC...
20-500A Hall Effect Current Sensor Transducer Programming Type Characteristics chart The TKC-TG3 ...
Programming hall sensor TKC-TF512 maily used in BMS of electric vehicle TKC-TF512 series is a kind ...
Wide Range Measurement 4800A Hall Effect sensor for inveter use TKC-GT1540 TKC-GT1540 series is a ...
1000-20000A Open Loop Hall Effect Current Sensor For Frequency Converter Applications Variable speed ...
High Precision Open Loop Hall Effect Current Sensor TKC-EKA Series Dismountable Open Loop Hall ...