Nanjing Chieful Science & Technology Co., Ltd. |
|
open loop device based on the measuring principle of the hall
effect, with a galvanic isolation between primary and secondary
circuit. It provides accurate electronic measurement of DC, AC or
pulsed currents.
Hall current sensors are widely applicable for acquisition and
feeback control of current signals in the current
monitoring,inverter,solar power management,current cabinet,DC motor
drive and UPS servo control systems.
Electrical characteristics | ||||||||
Type | CS050E | CS100E | CS200E | CS300E | CS400E | CS500E | ||
IPN | Primary nominal input current | 50 | 100 | 200 | 300 | 400 | 500 | A |
IP | Measuring range of primary current | 0~±100 | 0~±200 | 0~±400 | 0~±600 | 0~±800 | 0~±800 | A |
VOUT | Nominal output voltage | 4±1% | V | |||||
VC | Supply voltage | ±12~±15(±5%) | V | |||||
IC | Current consumption | VC=±15V <20 | mA | |||||
VD | Insulation voltage | AC/50Hz/1min 2.5 | kV | |||||
εL | Linearity | <1 | %FS | |||||
VO | Offset voltage | TA=25℃ <±25 | mV | |||||
VOM | Residual voltage | IPN→0 <±20 | mV | |||||
VOT | Thermal drift of V0 | IP=0 TA=–25~+85℃ <±1 | mV/℃ | |||||
TR | Response time | ≤3 | μs | |||||
f | Frequency bandwidth(-3dB) | DC~20 | kHz | |||||
TA | Ambient operating temperature | –25~+85 | ℃ | |||||
TS | Ambient storage temperature | –40~+100 | ℃ | |||||
RL | Load resistance | ≥10 | KΩ | |||||
Standard | Q/3201CHGL02-2016 |
Dimensions of drawing (mm) |
Remarks |
·Incorrect connection may lead to the damage of the sensor. |