IP55 Protection Level Copper Wire Motor Swimming Pool Plastic Water Pump

ModelVoltageHZPower(KW)Power(HP)Hmax(m)Qmax(m³/h)Port Size(inch/mm)
FLS-370220V-380V50/600.370.581150 1.5”
FLS-550220V-380V50/600.550.75121650 1.5”
FLS-750220V-380V50/600.751.0131750 1.5”
FLS-1100220V-380V50/601.11.5152150 1.5”
FLS-1500220V-380V50/601.52162550 1.5”


Description

 

low energy consumption, high lift, large flow, low operating noise;
The pump body is made of fiberglass plastic, which is small in size and durable.
The impeller and filter mesh are made of special plastic materials;
The motor shaft is stainless steel 304;
The common materials for mechanical seals are graphite and ceramics;
The coil is filled with epoxy resin;Easy operation, easy to use, easy to maintain, and spare parts supply;

The pump motor has a built-in high temperature protection switch, and the motor can stop automatically if it runs abnormally.Pump motor protection grade IP56, high dust and water resistance.
The pump motor has an insulation class of F, and the rated load of the motor can work continuously and reliably under the environment of 7°C or less.
The pump motor uses high temperature engineering plastic cooling fins.
The pump body is made of engineering plastic with high temperature and high hardness and is durable.
The pump uses an excellent hydraulic model with high flow, high efficiency and energy saving.
Equipped with imported low-noise bearings and imported mechanical seals to ensure low-noise operation and long-lasting sealing of pumps, long service life of bearings and mechanical seals

 

 

Working Conditions:

 

M edium temperature:5~50 C

Environment temperature:< 60 C2. Application :

FRE ESEA circulation&filtration pump canbe used for

aquaculture, water project, large sizeswimming pool,water park, etc.

 

Features :

 

1) Magnificent flow rate and lift, the core energy of water circulating, 2~3m suction lift

 

2) Engineering plastic body, pump can beeffectively protected under bad weather,long service life;

 

3) Seiko manufacturing, low noise duringthe pump working time;

 

4) Free-tool filter cover design, easy to maintenance;

5) IP55 protection level, with None-leakydesign;

 

6) German technology IBC bearing,100%copper wire motor, 24 hours running.

 

7) Anti rust cast-aluminum motor cover,fast heat dissipation;PPo plastic steel material impeller, resist high temperatureand corrosion

 

8) Silicone sealing ring, cover all wateringsection,enhance pump sealing system9) CE certificated, reliable and safety

 

Swimming Pool Filter Circulation Pump - Technical Requirements


1) The sum of the capabilities of the circulating water pump should be greater than or equal to the operating head required for filtration and backwashing of all systems.

 

2) A cleanable hair filter must be provided before circulating the pump.

 

3) Circulating pumps and motors should be easy to overhaul and maintain, and the design and construction of pumps and their components should be safe.

 

4) The mechanical seal of the circulating water pump should be corrosion-proof and work well in the swimming pool operating environment.

 

5) The size of the circulating water pump should be as compact as possible, and its power and mechanical structure are suitable for general swimming pool installation, load and environmental conditions.

 

6) The pump motor can work at full load within the range of plus or minus 10% of the rated voltage.

 

7) All pump motors should have thermal and current overload protection, set inside the motor or at the starting point of the line to provide locking rotation and running protection.

 

8), security protection level IP55.

 

Swimming Pool Filter Circulation Pump - Selection Points


1) For swimming pools with different requirements, the pool water circulation pumps should be set independently.

 

2) Use an aquatic swimming pool with similar properties. Other water circulation pumps should be set independently.

 

3) The circulating water pump should be determined by not less than two units working at the same time.

 

4) The circulating water pump should use a pump with low speed, low noise and high efficiency. The performance curve should be as smooth as possible, and the working range must be in the high efficiency area.

 

5) The pump casing, impeller and mechanical seal of the circulating water pump shall be made of corrosion-resistant materials.

 

6) Pumps and pipes connected to the pump should be equipped with shock absorption and noise reduction measures.

 

7) The flow rate of the suction pipe of the pump should be 1.0~1.5m/s; the flow rate of the water outlet of the pump should be 1.5~2.5m/s.

 

Swimming Pool Filter Circulation Pump - Construction, Installation Points


1) The construction and installation of the circulating water pump shall comply with the “Code for Construction and Acceptance of Installation of Compressors, Fans and Pumps” GB50275–98.

 

2) The pump foundation shall be constructed according to the design drawing. The anchor bolts of the stabilized motor shall be firmly integrated with the concrete foundation. The pre-buried holes shall be cleaned before pouring, the bolts themselves shall not be skewed, and the mechanical strength shall meet the requirements.

 

3) The pump base should have a damping rubber pad. The rubber pad is in close contact with the base surface. The outer casing has separation bolts and hot dip plating.

 

4) The pump is connected to the motor drive shaft, and the axial and radial tolerances do not exceed the specified value.

 

5) Pressure gauges and valves should be installed at the inlet and outlet of the pump.

 

6) Pipe connection: Connect the reducer/expansion pipe directly to the pump. The pump pipe installation should be carried out after the pump is positioned and leveled. Pump equipment must not bear the weight of the pipe. The installation sequence is a flexible shock absorbing joint, and the valve is in turn tightly attached to the water pump.

 

7), the piping flange should be consistent with the flange of the pump and valve. The direction of the valve installation handle should be easy to operate, the elevation is consistent, and the piping is neatly arranged.

 

8) Electrical connection: Fully protected against accidental contact, the junction box should be suitable for flexible connections.

Hot Products

Pool Pump 1 Hp Swimming Pool Copper Pump Swimming Pool Pump 4hp Model Voltage HZ Power(KW) Power(HP) ...
1.5 Hp Pool Pump 2 Hp Pool Pump Inflatable Swimming Pool Pump Model Voltage HZ Power(KW) Power(HP) ...
High Head Big Flow Rate Swimming Pool High Efficient Circulation Spa Water Pump Model Voltage HZ ...
Wear And Corrosion Resistant Small Noisy Salt Swimming Pool Spa Water Pump Model Voltage HZ Power(KW...
IP55 Protection Level Copper Wire Motor Swimming Pool Plastic Water Pump Model Voltage HZ Power(KW) ...
1.5hp 2hp Energy Save Swimming Pool Electrical Spa Water Pumps With Filter Basket Model Voltage HZ ...