Henan Tytion Machinery Co., Ltd. |
|
Electric Diesel Driven Portable Gunite Machine variable output
Portable Gunite Machine
Rotor Liner Repair of Portable Gunite Machine:
1. Use a delicate chisel to separate the liner from the rotor. Do
not use heavy hammer or other tools to break the particularly hard
and brittle rotor liner.
2. Thoroughly clean the joint surface of the side liner and rotor.
3. The surface is ground to the liner until the scar disappears.
4. When the lining plate is installed on the rotor, the column pin
should be coated with the surface of the lining plate. Special
attention should be paid to not making the column pin higher than
the surface of the lining plate, so as not to damage the rubber
sealing plate.
Parameters of Portable Gunite Machine:
Technical | Parameters | ||||
Model | PZ-5 | PZ-6 | PZ-6F | PZ-7 | PZ-9/WSP |
Throughput(m3/h) | 5-5.5 | 6 | 6-7 | 7 | 9 |
Transport Distance (Tidal Spray) (m) | 200 | 200 | 200 | 200 | 200 |
Applicable Material (Cement/Sandstone) Ratio | 1:3~5 | 1:3~5 | 1:3~5 | 1:3~5 | 1:3~5 |
Applicable Material (Water/Ash) Ratio | ≤0.4~0.45 | ≤0.4~0.45 | ≤0.4~0.45 | ≤0.4~0.45 | ≤0.4~0.45 |
Aggregate size (mm) | φ20 | φ20 | φ20 | φ20 | φ20 |
Working Pressure (MPa) | 0.2~0.4 | 0.2~0.4 | 0.6~0.8 | 0.6~0.8 | 0.6~0.8 |
Feeding height (m) | 1.1 | 1.1 | 1.1 | 1.1 | 1.1 |
Rotor speed (r/min) | 11 | 11 | 11 | 11 | 11 |
Motor Power (KW) | 5.5 | 5.5 | 7.5 | 7.5 | 7.5 |
Motor speed (r/min) | 960 | 960 | 960 | 960 | 960 |
Operation Method of Portable Gunite Machine:
After the preparation work is finished, the mixing material can be
added to the machine. The machine operator should first open the
main valve, the valve of the upper air duct opens 1/3 circles, and
then adjust the air pressure of the lower air duct (to the cyclone)
to about 0.05-0.1 MPa (depending on the delivery distance). Then
the sprayer opens the nozzle valve and gives the wet rock surface.
At this time, the operator can start the machine and start
shotcreting. Now the working pressure is about 0.2-0.4 MPa.
According to the water-cement ratio of mixtures and the length of
conveying distance, after adjusting and determining the wind
pressure to the cyclone, the upper air pipe valve is opened again
until there is no more material leakage at the machine outlet.
Pictures of Portable Gunite Machine:
Warehouse of Portable Gunite Machine: