Enviro Solutions Technology Co.,Ltd |
Verified Suppliers
|
|
HF gas analyzer TDLAS technology 19 inch NH3 HCL HF H2S CO CO2 O2
An HF gas analyzer is an instrument specifically designed to measure the concentration of hydrogen fluoride (HF) gas in industrial processes. Hydrogen fluoride is a highly corrosive and toxic gas that is commonly used in various industries, including chemical manufacturing, semiconductor fabrication, and metal processing. Monitoring HF levels is important for process control, worker safety, and environmental compliance.
Here are some key points about HF gas analyzers:
1. Measurement Principle: HF gas analyzers utilize various
detection technologies to measure hydrogen fluoride concentrations.
Common methods include ion-selective electrodes, non-dispersive
infrared (NDIR) absorption spectroscopy, and electrochemical
sensing. Ion-selective electrodes measure the potential difference
between an HF-sensitive electrode and a reference electrode, NDIR
analyzers measure the absorption of infrared light by HF molecules,
and electrochemical sensors generate an electrical signal
proportional to the HF concentration. Each method provides accurate
and real-time measurements.
2. Features: HF gas analyzers are designed for continuous
monitoring in industrial settings and offer features suitable for
process control. These may include:
- Robust Construction: Process analyzers are typically built to
withstand harsh industrial environments, with durable housings and
components that can resist corrosion and tolerate high
temperatures.
- Remote Monitoring and Control: Some analyzers can be integrated
into a control system or network, allowing for remote monitoring
and control of HF levels. This enables real-time data access and
facilitates proactive response to changes in HF concentrations.
- Data Logging and Reporting: Process analyzers often have built-in
data logging capabilities to store measurement data over time. They
can generate reports and provide data for compliance purposes,
process optimization, and historical analysis.
- Alarm Systems: Process analyzers may include configurable alarms
that can be set to trigger when HF concentrations exceed predefined
thresholds. Alarms alert operators to potential safety hazards,
process issues, or deviations from desired operating conditions.
- Calibration and Maintenance: Regular calibration and maintenance
are necessary to ensure accurate and reliable measurements. The
frequency of calibration and maintenance depends on the specific
analyzer and manufacturer's recommendations.
3. Measurement Range and Accuracy: HF gas analyzers have specific
measurement ranges and accuracies tailored for industrial
applications. The measurement range can vary depending on the model
and may cover low parts-per-million (ppm) levels up to high
percentages by volume. The accuracy of the measurements is
specified by the manufacturer and can vary between models.
4. Safety Considerations: Hydrogen fluoride is a highly corrosive
and toxic gas. When working with HF and HF gas analyzers, it is
crucial to follow proper safety protocols. This includes ensuring
proper ventilation, using appropriate personal protective
equipment, and implementing gas detection systems and emergency
shutdown procedures.
5. Minimal Maintenance: These analyzers typically have low maintenance requirements, ensuring consistent performance over time.
6. Compliance and Reporting: They can be used to ensure compliance with environmental regulations and generate reports for regulatory authorities.
7. Robust Design: Look for analyzers that are designed for reliability in industrial environments.
8. Integration Capabilities: Consider whether the analyzer can be integrated into existing control systems or data logging platforms.
It's important to note that specific HF gas analyzer models may
have additional features and specifications, so it is recommended
to consult the manufacturer's documentation or user manual for
detailed information on a particular device.
ESE-LASER-200 Laser Gas Analyser is a 19" 4U TDLAS gas analyzer for industrial online analysis .The gas analyzer combine multiple reflection long optical path technology that can analysis gas including NH3,HCL,HF,CH4,H2S,CO,CO2,O2 .
Specifiications
Linearity Error | ≤±1%FS |
Repeatability | ≤±1% |
Zero Drift | ≤±1%FS/half year |
Span Drift | ≤±1%FS/half year |
Calibration Cycle | ≤2 times/year |
Response time | ≤30S |
Interface Signal | |
Analog Output | 2*4-20mA output |
Analog Input | 2*4-20mA output |
Digital Output | RS485/RS232/GPRS |
Relay Output | 3(24V,1A) |
Operating Conditions | |
Power Supply | 100VAC-240VAC |
Purge Gas | 0.3Mpa-0.8Mpa |
Ambient Temperature | ’-20℃-+60℃ |