Wave Soldering 3RB-6 Gas Discharge Tube Surge Protector Metal Ceramic GDT 70V 75V 90V 230V 250V

 

Description of 3RB-6 Gas Discharge Tube Surge Protector

 

GDT is placed in front of, and in parallel with, sensitive telecom equipment such as power lines, communication lines, signal lines and data transmission lines to help protect them from damage caused by transient surge voltages that may result from lightning strikes and equipment switching operations. These devices do not influence the signal in normal operation. However, in the event of an overvoltage surge, such as a lightning strike, the GDT switches to a low impedance state and diverts the energy away from the sensitive equipment.

 

Our GDT offer a high level of surge protection, a broad voltage range, low capacitance, and many form factors including new surface mount devices, which makes them suitable for applications such as Main Distribution Frame (MDF) modules, high data-rate telecom applications (e.g. ADSL, VDSL), and surge protection on power lines. Their low capacitance also results in less signal distortion. When used in a coordinated
circuit protection solution with PolySwitch devices, they can help equipment manufacturers meet stringent safety regulatory standards.

 

 

Features of 3RB-6 Gas Discharge Tube Surge Protector

 

• Excellent response to fast rising transients
• Stable breakdown voltage
• GHz working frequency
• 8/20μs Impulse current capability: 10KA
• Non-Radioactive
• Ultra Low capacitance (<1.5pF)
• High insulation resistance
• Lead-free compliant
• RoHS and REACH compliant
• UL 497B Recognized: E465335
• Size: Ф6mm*8.5mm
•l Storage and operational temperature: -40~+90°C

 

Applications of 3RB-6 Gas Discharge Tube Surge Protector

 

•l Communication equipment
• CATV equipment
• Data lines
• Power supplies
• Telecom SLIC protection
• Broadband equipment

• ADSL equipment, including ADSL2+
• XDSL equipment
• Satellite and CATV equipment
• Test equipment
• Consumer electronics

 

Electrical Characteristics of 3RB-6 Gas Discharge Tube Surge Protector

 

Part NumberDC
Spark-over Voltage 1) 2)
3)
@100V/S
Impulse Spark-over Voltage 3)Insulation Resistance
4)
Capacitance @1MHzLife Ratings
Impulse Discharge Current
@8/20μs 5)
AC
Discharge Current @50Hz 1S 5)
Impulse Life @10/1000μS 100A 5)
100V/μS1KV/μS
MaxMaxMinMaxNominal
±5 times
Max 1 timeNominal 5 timesMin
DIPSMDDIP-FVVVpFKAKAATimes
3R070TB-63R070SB-63R070TB-6F70±20%50060011.5101510300
3R075TB-63R075SB-63R075TB-6F75±20%50060011.5101510300
3R090TB-63R090SB-63R090TB-6F90±20%75085011.5101510300
3R150TB-63R150SB-63R150TB-6F150±20%75085011.5101510300
3R230TB-63R230SB-63R230TB-6F230±20%60070011.5101510300
3R250TB-63R250SB-63R250TB-6F250±20%60070011.5101510300
3R300TB-63R300SB-63R300TB-6F300±20%70090011.5101510300
3R350TB-63R350SB-63R350TB-6F350±20%70090011.5101510300
3R400TB-63R400SB-63R400TB-6F400±20%800100011.5101510300
3R470TB-63R470SB-63R470TB-6F470±20%900110011.5101510300
3R600TB-63R600SB-63R600TB-6F600±20%1100130011.5101510300
Glow Voltage at 10mA ~60V
Arc Voltage at 1A............................................................................... ~10V
Glow to Arc transition Current ~1A
Operation and storage -40~+90°C
Climatic category (IEC60068-1) 40/90/21
Weight ~1.25g
Surface treatment………………………………………….....…………. DIP -Nickel Plated
SMD -Matte-tin plated
1) At delivery AQL 0.65 level II, DIN ISO 2859
2) In ionized mode
3) Tip or ring electrode to center electrode
4) Insulation Resistance Measuring Voltage:
70V, 75V at DC 25V
90V~150V at DC 50V
Other at DC 100V
5) Total current through center electrode, half value through tip respectively ring electrode. Terms in accordance with ITU-T Rec. K.12, IEC 61643-311, GB/T 9043.

 

Soldering Parameters - Wave soldering (Thru-Hole Devices)

Wave Soldering ConditionPb-Free assembly
PreheatTemperature Min100°C
Temperature Max150°C
Time (Min to Max)60-180 Seconds
Solder Pot Temperature280°C Max
Solder Dwell Time2-5 Seconds

 

 

Soldering Parameters - Reflow Soldering (Surface Mount Devices)

 

Reflow ConditionPb - Free assembly
Preheat-Temperature Min (Ts(min))150°C
-Temperature Max (Ts(max))200°C
- Time (min to max) (ts)60 -180 Seconds
Average ramp up rate ( Liquids Temp TL) to peak3°C/second max
TS(max) to TL - Ramp-up Rate5°C/second max
Reflow- Temperature (TL) (Liquids)217°C
- Time (min to max) (ts)60 -150 Seconds
Peak Temperature (TP)260 +0/-5°C
Time within 5°C of actual peak Temperature (tp)10 - 30 Seconds
Ramp-down Rate6°C/second max
Time 25°C to peak Temperature (TP)8 minutes Max
Do not exceed260°C

 

 
 
 

Hot Products

3RB-8 Series 3R 10KA 1.5pF Surge Protector Gas Discharge Tube GDT Arrester 75V-800V Arrestor ...
Wave Soldering 3RB-6 Gas Discharge Tube Surge Protector Metal Ceramic GDT 70V 75V 90V 230V 250V ...
3RB-5SS 5mmX5mmX7.5mm Gas Discharge Tube 90 Volt Gas Tube Arrester For Circuit Protection PCB Board ...
3RB-5S Max 1pF 3R 3 Electrode Gas Discharge Tube 75V-470V 10KA GDT 5x5x7.5mm for Surge Protection ...
3RA-6 Gas Discharge Tube Element 90V GDT for Lightning Surge Arrestor Protector 6mmX8.5mm 70V-800V ...
3RA-5SS 150V 250V 350V 5KA SMD Ceramic GDT Surge Protector Arrester Gas Discharge Tube Description ...