Home Companies CHINA EM TECHNOLOGY LIMITED

ISO 7500W Variable Frequency Inverters For Drawing Machine

CHINA EM TECHNOLOGY LIMITED
Active Member

Contact Us

[China] country

Address: Building A, No. 182, Qingxi Town, Dongguan City, Guagndong, China

Contact name:Shary

Inquir Now

CHINA EM TECHNOLOGY LIMITED

ISO 7500W Variable Frequency Inverters For Drawing Machine

Country/Region china
City & Province dongguan
InquireNow

Product Details

7.5KW 3phse 380V frequency Inverter for Drawing Machine 

  • The output torque is stable and accurate by using high performance vector control technology.
  • With strong adaptability to the reel diameter, start smoothly and stabilizing tension can be achieved at high and low speed.
  • Tension taper winding function, winding better.
  • Intelligent reel diameter recognition, high recognition accuracy, strong anti-disturbance ability;
  • Built in simple PLC, easy to deal with the site of the straight line wire drawing machine.
  • RS485 interface as standard, support Modbus protocol in RTU mode.
  • Intelligent parameter setting, internal preset several sets of common parameters, reduce user parameter setting workload.
  • Built-in various functional modules to effectively reduce external system costs.
  • With perfect inertia and torque compensation function, open loop tension control adaptability is stronger .
  • Technical Specification

    ItemSpecifications
    Standard functionsMaximum frequency

    Vector control: 0~320 Hz

    V/F control: 0~3200 Hz

    Carrier frequency0.5–16 kHz (The carrier frequency is automatically adjusted based on the load features.)
    Input frequency resolution

    Digital setting: 0.01 Hz

    Analog setting: maximum frequency x 0.025%

    Control mode

    Sensor-less vector control (SVC)

    Closed-loop vector control (FVC)(+ PG card)

    Voltage/Frequency (V/F) control

    Startup torque

    G type: 0.5 Hz/150% (SVC); 0 Hz/180% (FVC)

    P type: 0.5 Hz/100%

    Speed range1:100 (SVC)1:1000(FVC)
    Speed stability accuracy± 0.5% (SVC)± 0.02% (FVC)
    Torque control accuracy± 10% (SVC)± 5% (FVC)
    Overload capacity

    G type: 60s for 150% of the rated current, 3s for 180% of the rated current

    P type: 60s for 120% of the rated current, 3s for 150% of the rated current

    Torque boost

    Auto boost

    Manual boost 0.1%~30.0%

    V/F curve

    Straight-line V/F curve

    Multi-point V/F curve

    N-power V/F curve (1.2-power, 1.4-power, 1.6-power, 1.8-power, square)

    V/F separationTwo types: complete separation; half separation
    Acceleration/deceleration curve

    Straight-line ramp

    S-curve ramp

    Four groups of acceleration/deceleration time with the range of 0.0s~65000s

    DC braking

    DC braking frequency: 0.00 Hz ~ maximum frequency

    Braking time: 0.0s~36.0s

    Braking trigger current value: 0.0%~100.0%

    JOG control

    JOG frequency range: 0.00Hz~50.00 Hz

    JOG acceleration/deceleration time: 0.00s~6500.0s

    Built-in simple PLC, multiple speedsIt realizes up to 16 speeds via the simple PLC function or combination of DI terminal states.
    Built-in PIDIt realizes closed loop control system easily.
    Auto voltage regulation (AVR)It can keep constant output voltage automatically when the mains voltage fluctuation.
    Overvoltage/ Over current stall controlThe current and voltage are limited automatically during the running process so as to avoid frequently tripping due to overvoltage / over current.
    Rapid current limit functionIt can auto limit running current of frequency inverter to avoid frequently tripping.
    Torque limit and control

    (Excavator characteristics) It can limit the torque automatically and prevent frequently over current tripping during the running process.

    Torque control can be implemented in the VC mode.

    Individualized functionsHigh performanceControl of asynchronous motor and synchronous motor are implemented through the high-performance current vector control technology.
    Instant power off not stopThe load feedback energy compensates the voltage reduction so that the frequency inverter can continue to run for a short time.
    Rapid current limitTo avoid frequently over current faults of the frequency inverter.
    Virtual I/OFive groups of virtual DI/DO can realize simple logic control.
    Timing controlTime range: 0.0~6500.0 minutes
    Multi-motor switchoverTwo motors can be switched by two groups of motor parameters.
    Multiple communication protocolsIt supports communication bus via Modbus-RTU, PROFIBUS-DP, CANlink and CANopen.
    Motor overheat protectionThe optional I/O extension card enables AI3 to receive the motor temperature sensor input (PT100, PT1000) so as to realize motor overheat protection.
    Multiple encoder typesIt supports various encoders such as differential encoder, open-collector encoder, resolver, UVW encoder, and SIN/ COS encoder.
    Advanced background softwareIt supports the operation of frequency inverter parameters and virtual oscillograph function, by which the state of frequency inverter can be monitored.
    RUNRunning command givingkey panel; Control terminals; Serial communication port; You can switch between these giving in various ways.
    Frequency giving

    There are 10 kinds frequency giving: digital setting, analog voltage setting, analog current setting, pulse setting and serial communication port setting.

    You can switch between these giving in various ways.

    Auxiliary frequency givingThere are 10 kinds auxiliary frequency giving. It can implement tiny tuning of auxiliary frequency and frequency synthesis.
    Input terminal

    Standard:

    6 digital input (DI) terminals, one of which supports up to 100 kHz high-speed pulse input

    3 analog input (AI) terminals, AI1,AI2 support 0V~10 V or 0mA~20mA input, AI3 support -10V~+10V

    Expanding capacity:

    many DI terminals

    Output terminal

    Standard:

    1 high-speed pulse output terminal (open-collector) that supports 0–100 kHz square wave signal output (Can be used as DO output)

    2 relay output terminal

    2 analog output (AO) terminals, both of them supports 0mA~20mA current output and 0V~10V voltage output.

    Expanding capacity:

    many DO terminals

    many relay output terminals

    Display and keypad operationLED displayIt displays the parameters.
    Parameters copyOptional LCD keypad can copy parameters. (Option)
    Key locking and function selectionIt can lock the keys partially or completely and define the function range of some keys so as to prevent misoperation.
    Protection modeMotor short-circuit detection at power-on, input/output phase loss protection, over current protection, overvoltage protection, less voltage protection, overheat protection and overload protection,etc.
    EnvironmentInstallation locationIndoor, no direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapour, drip or salt.
    AltitudeLower than 1000 m
    Ambient temperature-10°C~ +40°C (de-rated if the ambient temperature is between 40°C and 50°C)
    HumidityLess than 95%RH, without condensing
    VibrationLess than 5.9 m/s2 (0.6 g)
    Storage temperature

    -20°C ~ +60°C

     

 

 

 

 


  •  

Hot Products

7.5KW 3phse 380V frequency Inverter for Drawing Machine The output torque is stable and accurate by ...
132KW Variable Frequency Inverters AC 380V built in PLC for water pump EM15 series frequency ...
75KW Variable Frequency Inverters 0 to 3000Hz output frequency for ac motor EM15 series frequency ...
110KW Variable Frequency Inverters 380V for CNC Engraving Machines EM15 sereis is a new-generation ...
AC input 3 phase 380V 90KW Variable Frequency Inverters for injection molding machine EM15 is a new...
Vector control 55KW Variable Frequency Inverters 3phase 380V inverter EM15 series has excellent ...