3Kg Fm200 Fire Extinguisher Tube With GB25972-2010 Standard

 

Parameter:

No.SpecificationTechnical parameter
1TypeFm200 direct type
2modelWZ-Q/T-QZ3-XJ60
3Working pressure2.5Mpa
4Max working pressure4.2Mpa
5Working temperature0-50℃
6Density of unit volume0.7kg/m3
7Max length of detecting tube20m
8Quantity of agent3kg

 

Description:

 

This gadget uses a pressurized fire trace tube that connects to an extinguishing agent storage to detect fire situations. For this device, you can use carbon dioxide or HFC-227ea/FM200 as an extinguishing agent.

 

It would typically be built to accommodate both direct release and indirect release modes of discharge. When a fire starts, the fire trace activates the system, which releases an extinguishing agent directly through the fire trace tube. This is known as direct release. Another method, which we refer to as indirect release, uses the fire trace tube to immediately release an extinguishing agent after it has detected a fire.

 

A suitable tool for addressing the lack of fixed devices is the fire trace extinguishing device. Because it can be utilized in confined spaces or unusual environments where it is impossible to install fire alarm systems, pipelines, or nozzles.

 

 

Applications:

 

Power plants, communications, broadcasting, petrochemical, railway ans so on system.

 

              

 

 

Working principle:

  

The fire detecting tube can be fixed wherever that fire can easily occur thanks to its soft characteristics. As a result, the fire can quickly break the fire detecting tube when there is a fire in the cabinet. When the fire detection tube breaks, the air pressure shifts, causing the fire agent to emerge and spray out of the hole where it broke to put out the fire. The small alarm bell on the top of the fire extinguisher sounds simultaneously to alert users to the presence of a fire and request that they inspect it and refill the system.

 

Components:

 

 

This extinguishing device does not require pipe fittings or electrical components to form a system. It might even be an actual fire suppression system.

 

A cylinder, a fire detecting tube with a maximum length of 25 meters, a container valve, and two different types of agents—co2 and fm200—make up the direct type fire detecting tube fire suppression system.

 

The components of the indirect type fire detecting tube fire suppression system are identical to those of the direct type with the addition of a release tube. Unlike the direct type, where the fire detecting tube can be used for both detecting and releasing, this system only uses the fire detecting tube for the detecting function, necessitating the addition of a release tube.

 

 

The fire detecting tube fire suppression device has the following advantages:

 

1. Easy transportation and installation. The only thing left to do after installing the cylinder is to install the detecting tube around a potential source of fire because this system integrates fire fighting and alarm function together and does not require matching electrical elements and pipe fittings.

 

2. The manual start mode. The system may be turned on without any power. The working principle of this device relies on internal storage pressure rather than an external force to activate it. The agent will release after the fire breaks the sensing tube.

 

3. Not much room is occupied. Instead of protecting a protected zone, this approach is more suited for securing a system like a communications network. The cylinder is fixed to the outside cabinet and won't take up much space.​​

Company Introduction:


Guangzhou Xingjin Fire Equipment Co., Ltd., a company that plays a significant role in communication between China and the rest of the globe, is situated in this city and is surrounded by excellent transportation and a lovely environment. We are a manufacturer, and we focus on the research and development of HFC-227ea (FM200) products with the help of our experienced and qualified staff, which includes the program design team, the skilled installation team, the quality detecting team, and the after-sale service team. These days, many of our well-known FM200 products are in use, including the automated FM200 fire extinguisher (ceiling mounted style), the cabinet type FM200 fire suppression system, the pipe network FM200 fire suppression system, the fire detecting tube suppression system, and the automatic fire suppression tube.

 

 

Hot Products

3Kg Fm200 Fire Extinguisher Tube With GB25972-2010 Standard Parameter: No. Specification Technical ...
High pressure CO2 fire extinguishing system Description: A CO2 fire extinguishing system is a type ...
Novec1230 Hfc227ea White Fire Suppression Tube Automatic Cover 0.5 Cubic Meter Automatic fire ...
3Kg Fm200 Fire Extinguisher Tube With GB25972-2010 Standard Parameter: No. Specification Technical ...
Novec1230 Hfc227ea White Fire Suppression Tube Automatic Cover 0.5 Cubic Meter Automatic fire ...
3Kg Fm200 Fire Extinguisher Tube With GB25972-2010 Standard Parameter: No. Specification Technical ...