Guangzhou Xingjin Fire Equipment Co.,Ltd. |
Verified Suppliers
|
|
Description of Fire extinguishing agent
IG100 uses nitrogen with a 100% nitrogen content as the extinguishing agent in order to appropriately embrace the design concept of the new era fire extinguishing system. As a result, the product has features that effectively safeguard the environment and put out fires. It has the ability to protect the planet's ecological environment, provide clear and safe visibility, and stop pollution from fire fighting equipment. Nitrogen may be manufactured from a variety of sources and separated from air with low filling costs. The fire extinguishing system, which lowers the oxygen in the combustion zone, puts out fires via suffocation.
Parameters of Fire Suppression System
No. | Specification | Technical Parameter | |
1 | Working Pressure | 15Mpa | |
2 | Device Model | QMD15/80 | QMD15/90 |
3 | Capacity | 80Ltr | 90Ltr |
4 | Filling Capacity of Gas | 14.25kg | 16.04kg |
5 | Outside Diameter of Cylinder | Φ279mm | Φ325mm |
6 | Height of Cylinder | 1578+73mm | 1345+60mm |
7 | Spraying Time | ≤10s | |
8 | Max Filling Rate | 0.178kg/L | |
9 | Power | DC24V/1.6A | |
10 | Nitrogen Pressure of Driving Device | 6.0±1.0Mpa(20℃) | |
11 | Condition of Reserving Room for Container | temperature: 0~50℃ | |
12 | Max Working Pressure | 17.2Mpa | |
13 | Min Working Pressure | 13.6Mpa |
Application of Fire Suppression System
Fire suppression systems are designed to detect, contain, and extinguish fires in buildings, vehicles, and other enclosed spaces. Here are some common applications of fire suppression systems:
In general, fire suppression systems are crucial for preventing the disastrous impacts of fires on people and property. To make sure they'll work in an emergency, they should be installed and maintained by trained experts. To achieve the highest level of safety, fire suppression systems should be utilized in conjunction with fire preventive strategies including routine fire drills, smoke detectors, and fire extinguishers.
Advantages
When compared to the standard 15MPa system, the number of fire extinguishing agent cylinders may be reduced by 25% to 50%.
A constant 6MPa low pressure release can lower the cost of pipeline and pipe fittings.
Packages
We always place it into a wooden case after first packing it with polyfoam. At times, we will create a pallet for the goods in order to satisfy clients or meet safety requirements.
Mimic Diagram
Single/Multiple cylinder(s) for multiple zone
Single/Multiple cylinder(s) for one zone
After-Sale Service
• We have an efficient sales and after sales team to promise slove all client's question in time.
• We provide 8×6 hrs technical support and service.