Home Companies Dongguan HOOHA Electrical Equipment Company Limited

Roof Photovoltaic Module Wire Testing Equipment UL 790 ZY6271 IEC 61730 - 2

Dongguan HOOHA Electrical Equipment Company Limited
Active Member

Contact Us

[China] country

Address: ROOM 1205, 12/F, TAI SANG BANK BUILDING, 130-132 DES VOEUX ROAD,CENTRAL, HONG KONG

Contact name:Jack young

Inquir Now

Dongguan HOOHA Electrical Equipment Company Limited

Roof Photovoltaic Module Wire Testing Equipment UL 790 ZY6271 IEC 61730 - 2

Country/Region china
City & Province hong kong hong kong
Categories Electrical Wires
InquireNow

Product Details

 

Scope of application:


The roof combustion test system is an instrument that evaluates the fire resistance of the roof and components in the simulated real conditions and evaluates the grade A~C level of the sample at A1.82 m, B 2.4m and C 3.9 m. At the same time, it can be used for flame retardant performance test of photovolt battery.

 

Meet the standard:


The smoke detection monitor of individual residential units in multi-family homes and hotel rooms: electric signal detectors to detect the smoke status of residential buildings;

Compliance with UL 790: standard fire test method for roofing materials;

Compliance with IEC 61730-2 appendix A: photovoltaic module combustion test;

Meet ASTM E 108-04: standard fire test method for roofing material.

 

Main parameters:


The cylinder can easily control the slope of the deck

2 fire prevention board is attached with test deck

Use automatic control valve to adjust the temperature

- grade A, B: 760-28 ℃ (1400 + 50 ℉) - 1400 ~ 21000 Btu/min (369 ~ 387 kWh)

- grade C: 704-28 ℃ (1300 + 50 ℉) - 1300 ~ 18000 Btu/min (316 ~ 334 kWh)

Each gas transmitted to the burner must be tested and controlled in different ways

-lng: use MFM to measure air flow accurately (air flow is controlled by automatic control valve)

- LPG: use the inverter system to adjust the air flow rate: the test deck has a speed of 19 + 8 km/h(5.5 m/SEC)

Using automatic ignition method, the test can be automatically ignited at the same time

A guide board is attached to the vent line to protect the flow turbulence of the supply test deck from outside interference

A slope adjustment panel is installed in the ventilation pipeline to adjust the direction of air flow

12 top burner 58.7 mm equipped with thermocouple, can test the temperature to 888 + 28 ℃

Use DAQ system to automatically control and complete the test

Hot Products

ZY6235 Pavement Material Radiant Heat Flux Test Device With Powerful Exhaust System Scope of ...
ZY6290 Ethylene Plastic Wire Testing Equipment Flame Retardant Tester Machine Scope of application: ...
ZY6290A Bus-Groove Cable Wire Tester , Water Fire Wire Harness Testing Equipment Scope of applicatio...