Home Companies DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD

DX8409 High Temperature Constant Temperature Oil Tank

DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD

Contact Us

[China] country

Trade Verify

Address: No.168 Zhen'an West Road Changlian Industry Mansion Xiabian Community Dongguan China

Contact name:Sophia Su

Inquir Now

DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

DX8409 High Temperature Constant Temperature Oil Tank

Country/Region china
City & Province dongguan guangdong
Categories Optical Instruments
InquireNow

Product Details

DX8409 High Temperature Constant Temperature Oil Tank

 

Standards: UL758, UL1581, UL62, ASTM, GB-1690 and other test standards.

Scope of application: It is mainly used for the oil resistance test of varnished wire, insulating cover and other plastics. The specimen is immersed in the test oil at the specified temperature, and the specimen is taken out after a certain period of time, and the tensile residual value is measured, and the quality of the coating film is checked for the varnished wire. The temperature control system is controlled by microcomputer and has PID function, which makes the control accuracy high and stable; It is equipped with a timer alarm function, which will automatically alarm when the set time is reached.

Technical Parameters:

Specimens: dumbbell specimens, enameled wires

Number of samples: test cup * 6 ¢ 5 * 15 deep

Temperature control range: room temperature ~ 300°C can be adjusted arbitrarily

Power: 1600W

Sump temperature uniformity: <1.5°C

Test oil: 2# lubricating oil and insulating oil (provided by the user)

Time control: 0~999 hours and 99 minutes.

Carton size: 650 (length) × 400 (width) × 350mm (height)

Sump size: 300 L) × 300 (W) × 200mm (D)

Power supply: AC220V/50HZ

Notes:

When the machine is at a high temperature, take care to prevent burns.

After the test is completed, please turn off the power supply, and unplug the power cord if it has not been used for a long time.

Pay attention to the cleanliness of the surface of the machine.

The test oil needs to be replaced after a trial phase

Directions:

When using the instrument, fill the oil tank with oil first.

Turn on the power.

Set the temperature at which the test is to be conducted. Look at each other.

Start the heating.

After reaching the test temperature, the test sample is inserted.

Set the time when you want to experiment.

When the alarm sound is heard, the test ends.

Hot Products

DX8382 Large Combustion Cabinet UL1581 Combustion Testing Machine, Vertical and Horizontal ...
DX8391 Fire Retardant Coating Combustion Tester (Small Room Method) Scope of application: It is ...
DX8399 Vertical Combustion Tester for Rigid Foam 【Product Introduction】This machine is suitable for ...
DX8401 Radiant Heat Flux Test Device for Floor Covering Materials 12w Scope of application: It is ...
DX8409 High Temperature Constant Temperature Oil Tank Standards: UL758, UL1581, UL62, ASTM, GB-1690 ...
DX8426 Building material decomposition smoke density testing machine Scope of application: It is ...