Cabinets to connect patch panels to active equipment.
Cross connects in data centres.
Suitable for use in the work area to connect the workstation to the
wall outlet (Fibre To The Desk).
Characteristics
Patch cord cable is according to IEC 60794-2-50
Maximum insertion loss according to IEC 61300-3-4: 0.25 dB
Typical insertion loss: 0.1 dB
Minimum return loss according to IEC 61300-3-6 for LC/UPC: 50 dB
Minimum return loss according to IEC 61300-3-6 for LC/APC: 65 dB
Duplex LC-LC, duplex LC-SC and duplex SC-SC patch cords have a
duplex cable construction with a diameter of 2 X 2.0 mm.
Short connector boots of 19mm
Small bend radius: 10 mm
A traceability label is added close to the connector
Technical Parameters:
ter | Unit | FC, SC, LC | ST, MU | MT-RJ, MPO |
SM | MM | SM | MM | SM |
PC | UPC | APC | PC | PC | UPC | PC | PC |
Insertion loss(typical) | dB | ≤0.3 | ≤0.2 | ≤0.3 | ≤0.2 | ≤0.3 | ≤0.3 | ≤0.2 | ≤0.3 |
Return loss | dB | ≥45 | ≥50 | ≥60 | ≥30 | ≥45 | ≥50 | ≥30 | ≥45 |
Operating wavelength | nm | 1310, 1510 | 1310, 1510 | 1310, 1510 |
Exchangeability | dB | ≤0.2 | ≤0.2 | ≤0.2 |
Vibration | dB | ≤0.2 | ≤0.2 | ≤0.2 |
Operating temperature | ℃ | -40~75 | -40~75 | -40~75 |
Storage temperature | ℃ | -45~85 | -45~85 | -45~85 |
Cable diameter | mm | φ3.0, φ2.0, φ0.9 | φ3.0, φ2.0, φ0.9 | φ3.0, φ2.0, φ0.9 |