Home Companies YUEQING FEEO ELECTRIC CO.,LTD

Widening Handle AC415V 3P Overcurrent Circuit Breaker

YUEQING FEEO ELECTRIC CO.,LTD
Active Member

Contact Us

[China] country

Address: Keaisi Road, Xiangyang Industrial zone , Yueqing, Zhejiang,China.

Contact name:Terence

Inquir Now

YUEQING FEEO ELECTRIC CO.,LTD

Widening Handle AC415V 3P Overcurrent Circuit Breaker

Country/Region china
City & Province zhejiang
Categories Battery Chargers
InquireNow

Product Details

FE-125 125 A AC MCB 415V 3P Electrical Circuit Breakers

 

FE-125 high breaking capacity circuit breaker is used for AC 50/60HZ, single-pole 230V or two, three, four-pole 415V

circuit for protecting the circuit that overload and short circuit may take place. It can be used in lighting and electric motor

distribution system. Mean while it is applicable to an unfrequented switch over the electric apparatus and lighting circuit

under normal condition. Breaking capacity is up to standard of IEC60947-7 10KA.

 

Specifications

 

Rated Voltage230V/415V   AC 
Rated Current63, 80, 100, 125 A
Characteristic CurveB,C,D
No of Pole1p ,2p,3p,4p
Electrical Life6000 times
Mechanical Life20000 times (C.O)
Weight1P2P3P4P
150300450600

 

Dimensions

 

Over current tripping characteristic

ItemRated Current(A)Initial StateTest CurrentLimited TimeProspective ResultStarting State
aIn=63Cold State1.05Int ≤1hNon-tripping 
In>63Cold State1.05Int≤2hNon-tripping
bIn=63Hot State1.3Int<1hTrippingThe current rise steadily to a fixed value within 5s
In>63Hot State1.3Int<2hTripping
cIn≥63Cold State8Int≤0.2sNon-Tripping 
12Int<0.2sTripping

 

Characteristics Curve

 

Current correction values used at different ambient temperatures

 

Current correction factor used at different altitudes

Rated Current (A)Different altitude correction factors
≤2000m2000m~3000m>3000m
63,80,100,125A1.00.90.8


Accessories

Application

ItemCodeApplicationStandard
Auxiliary ContactsOFOffer auxiliary signal control auxiliary circuit

IEC60947-5-1

GB14048.5

Alarm ContactsSDProvide an alarm signal when the MCB trip off

IEC60947-2

GB14048.2

Shunt TripperHDMXIt will let the MCB trip off when the operating voltage exceed the rated voltage by 70%~110%

IEC60947-1

GB14048.1

Shunt Tripper + Auxiliary ContactMX+OFRemote break the circuit and let the auxiliary contacts control the circuit

IEC60947-1

GB14048.1

Over/under Voltage ReleaseMV+MNIt can peotect the MCB from under / over voltage

IEC60947-2

GB14048.2

 

Technical Data

 

 

  Working Condition

 

 Temperature: -5℃~+40℃

 Altitude : under 2000m

 Installation : 35mm DIN rail

 

Dimensions

 

 

 

Hot Products

FE-125 high breaking capacity circuit breaker is used for AC 50/60HZ, single-pole 230V or two, three...
FE-125 125 A AC MCB 415V 3P Electrical Circuit Breakers FE-125 high breaking capacity circuit ...
FE-125 high breaking capacity circuit breaker is used for AC 50/60HZ, single-pole 230V or two, three...
FEM1 AC Moulded Case IEC60947-2 2P Earth Leakage Circuit Breaker FEM1 series moulded case circuit ...
FEM1 series moulded case circuit breaker is a new type product developed and manufactured by ...
FEM1 IEC60947-2 AC 63A-800A 2000m AC Circuit Breaker FEM1 series moulded case circuit breaker is a ...