Vican Explosion Proof Technology Co.,ltd |
|
Hazardous location junction box with the GB3836 explosion-proof
2000 regulation, flameproof, made its mark is ExdIIB explosion.
Applicable to contain type IIA, IIB, the corresponding temperature
classes with explosive air mixture of district 1, 2 division
places.
Explosion-proof box as flameproof explosion-proof parts, can be
used as a control, lighting or power line cable branch connection
with, also can be used as tankers power circuit.
1. Execution standards: GB3836.1, GB3836.2, GB3836.3, GB12476.1,
IEC60079
2. Rated voltage: AC 380V/220V/110V/36V/24V
3, rated current: 20A-200A
4, explosion-proof mark: ExeII T6 ExtD A21
5, protection level: IP65
6, anti-corrosion grade: WF1
7. Introduction port specification: G1/2"~G2.5"
Junction box general size | ||
EXe(mm) | EXd IIB(mm) | EXd IIC(mm) |
135*135*100 | 200*200*130/150 | 200*200*130 |
135*200*100 | 200*300*150/180 | 300*300*150 |
200*200*100 | 300*300*150/180 | |
200*300*150 | 300*400*150/180 | |
300*300*150 | 400*500*160 | |
300*400*150 | 400*500*200 | |
400*500*150 | 500*600*160 | |
500*600*200 | ||
500*600*250 | ||
The above dimensions are made of aluminum alloy. If it needs custom-made, it can be Steel plate welding or stainless steel. |
Application:
1. Explosive gas mixture hazardous locations: Zone 1 and Zone 2.
2. Explosive gas mixtures: IIA, IIB, IIC.
3, flammable dust environment:20,21,22 area
4, explosion-proof signs: ExdeIIBT6, ExdeIICT6
5.often be used in chemical plant,gas station,oil
station,workshop,warehouse, pharmaceuticals,smelting, shipbuilding,
military, textile and other flammable and explosive places
The dust site is divided into three areas: 20, 21 and 22:
Zone 20: Combustible dust continuously or frequently occurs during normal
operation in an amount sufficient to form a mixture of flammable
dust and air and/or a location and container interior that may form
an uncontrollable and extremely thick dust layer.
Zone 21: During normal operation, there may be a place where the amount of
dust is sufficient to form a mixture of flammable dust and air but
not zoned 20. This area includes locations directly adjacent to the
charge or discharge of dust, where dust layers and flammable
concentrations of flammable dust and air may be produced under
normal operating conditions.
Zone 22: Under abnormal conditions, flammable dust clouds occur
occasionally and are only present for a short period of time, or
flammable dust occasionally accumulates or may present a dust layer
and produce a flammable dust air mixture but not zoned into Zone
21. If it is not guaranteed to exclude flammable dust accumulation
or dust layer, it should be divided into 21 zones.