Sinuo Testing Equipment Co. , Limited |
Verified Suppliers
|
|
IEC 62196 Electric Vehicle PLC Controled Glow Wire Test Apparatus
Complied Standards & Clauses
IEC 62196-1 Ed.4CDV 2020 clause 29.5.
IEC60695-2-10, IEC 60695-2-11, IEC
60695-2-12, IEC60695-2-13.
Equipment Overview
This device simulates the thermal stress test of glowing component
or heat source like overload resistance or ignition source which is
caused in s short time. It is suitable for electric and electronic
products, household appliances and other material to do fire hazard
testing. It is also used in the No flame ignition source fire test
to test initiation temperature and flammability index of related
glowing filament.
Test principle and products feature:
Test principle: the glowing filament whose material and shape is
required(Ni80/Cr20) is heated to the testing temperature of 550 ℃ ~
960 ℃ for 1 min by using the glow wire tester with large current.
Then using required pressure (1.0N) vertically burns the test
sample for 30s. By observing whether the test sample and bedding
object ignite or the burning time, the users can judge the ignition
danger of electric and electronic products. It is used for the
ignition test, ignition temperature (GWIT) test, flammability test
and flammability index (GWFI) test of solid insulating material and
other solid combustible material.
Products feature: Adopting advanced PLC control, and 7 inch color
touch screen, it is with solenoid valve switch to control the
burning depth of test sample and equipped with measuring gauge,
this device has the features of exact and rapid. The test sample
will break away automatically from glowing filament after reaching
the set time. Adopting the original imported UK LAB K type
armour(1mm)whose temperature resistance is up to 1100°(exceed
1050°of standard requirement) , this device is with accuracy
temperature control.
Technical Parameters
Control | Advanced PLC |
Display | 7” color touch screen |
Glowing Element | Ф4mm ± 0.04mm Ni/Cr(77/20) special standard |
Thermocouple | 1mm import K thermocouple (Brand: RS), the |
Temperature Precision | 500°C-750°C+10%, 750°C-960°C+10% |
Specimen pressure | 0.95N±0.1N( adjustable ) |
Maximum depth of | 7mm ± 0.5mm |
Specimen movement | 10mm /s ~ 25mm /s |
Testing time | 30s±0.1s(1s ~ 999.9s digital display preset ) |
Thickness of ignite | Thickness10mm, white pine board cover |
Volume of test site | ≥ 0.5m³, black background, background illuminance ≤ 20Lx |
Dimension and weight | W: 1100mm × D: 550mm × H: 1200mm, |
Power | 220V/50Hz |
Standard | IEC60695-2-10, IEC 60695-2-11, IEC 60695-2-12, IEC60695-2-13, UL746A , IEC 60335, IEC 60598, etc. |
Deatils: