PS-I01GK Instructions for the use of elevator floor sensor devices

This device is suitable for all need to PNP-type level sensor signal elevator, the device to overcome the photoelectric and traditional
flat-layer switch inherent vulnerability of the shortcomings, high reliability and precision and fast response capability, low price Very high price.

Main characters:

1. Output high level is 23.2V, low level is 0V, load current is large, wide application range.

2. The output signal is square wave pulse signal, fast response and reliable, easy to host the signal processing.

3. Ultra-low current consumption: 15mA, product life long.

4. The circuit has a power supply reverse protection, output short circuit protection and prevent malfunction and other protection functions. 

5. Circuit with anti-± 6KV high voltage static, ± 4.5Kv group pulse and surge protection.

6. Electrical performance in line with "International Electrotechnical Commission (IEC)" standard requirements;

7. High reliability, small size, installation and commissioning is very convenient. Simple structure, low price.

Technical Specification:

Application Range:Applicable to all need to PNP-type level switch signal elevator
Response time4ms
Current consumption15mA
4Load current120mA
5.Output form:PNP switch signal: no metal into the sensor area; output 0v low; a metal into the sensor area when the output high.
6Working temperature:-25~55℃
7Working environment humidity35%~85%RH
8Power supply:DC 24V(±5%),Machine operating current≤100mA
9.Protection classIP53
10Withstand voltage1000V ,50Hz,1 minute
11Insulation resistanceDC500V,≥20MΩ,
12Install Position:The elevator car is close to the partition board
13Overall Size:

100mm*65mm*25mm

Working Principle:

During the operation of the elevator, the system is based on the installation of the elevator shaft into the sensor area of the induction sensor area, the magnetic
plate produced by the eddy current effect, weaken the electromagnetic field within the sensing area, so that the device sensor internal oscillation circuit stop Vibration,
through the signal processing and amplification of a 23.2v high-level pulse signal; when the isolation plate from the layer sensor sensor area, the induction area of the
electromagnetic field back to normal, the oscillation circuit to start again, the product output low , Thereby achieving the determination of the position of the elevator
car and the purpose of reaching the elevator deck

 

Product appearance and electrical wiring diagram:

 

l System wiring principle:

No.Cable colorWiring instructions
1(Brown)+DC24V
2(Blue)Com
3(Black)Signal output

 

 

Never connect the device's output cable directly to an external power supply, which may cause permanent damage.

 

Installing Method:

 

 

Adjustment:

 

⒈First of all, according to the hoistway inside the magnetic disk bracket bracket installed on the magnetic plate, and then installed in the straight beam position of the
device fixed bracket. Finally, adjust the position of the leveling sensor according to the position of the magnetic plate, make sure that the partition plate is in the center
of the sensing area of the device. The partition plate can not damage the device during the operation of the elevator.

2. After securing the installation position, connect the product terminals according to the above system wiring principle. One end is connected with the main unit and one
end is connected to the output port of the unit. ,

3. In the process of moving up and down the elevator, the magnetic plate into the device sensing area, the product indicator light will be red, the output high, separated
from the device sensing area, the product indicator light off, the output low The At this point, the product into the normal working state debugging is completed.

 

other:

Instruction Manual:1 set

Tighten the screws(M5*30) 2sets

If the system is abnormal during debugging or use, please contact us directly.


Products photo show:

 

 



Contact Person:Miss Yolly
Website:www.estlift.com/www.est-lift.com
E-mail:yollyapple@163.com

           sales01@xaest.com

Skype:yollyapple
Wechat:YollyApple

Whatsapp&Mobile:+86 189 9286 2361
Tel:+86-029 8841 6613-808

Fax:+86-029 8556 5714-886 

Hot Products

PS-I01GK Instructions for the use of elevator floor sensor devices This device is suitable for all ...
Detailed Product Description Closers DC-001 / elevator parts DOOR CLOSER Elevator door closer, ...
Picture for your reference: Elevator shaft measuring rail mounting localizer / seek feet / laser ...
The elevator hoistway measurement JAZ-E052 made in China Elevator shaft measuring rail mounting ...
Elevator shaft measuring rail mounting localizer / seek feet / laser vertical collimator / automatic ...
Elevator shaft measuring rail mounting localizer / seek feet / laser vertical collimator / automatic ...