Growth Medical Aging Equipment Environmental Temperature Humidity Climate Test Chamber

Country/Region china
City & Province shanghai shanghai
InquireNow

Product Details

Growth Medical Aging Equipment Environmental Temperature Humidity Climate Test Chamber

Equipment summary:

Environmental Constant Temperature Humidity Climatic Test Chamber is applied to test the materials in heat-resistance, cold-resistance, dry-resistance, moisture-resistance. It is simple to operate and program easy to edit. It can show the set values and operative time.

 

Applicable industries:
Environmental Constant Temperature Humidity Climatic Test Chamber applied to control the product
quality, such as electronic, plastic products, electrical appliances, instruments, food, vehicles, metals,
chemicals, building materials, aerospace, medical care and so on.

Detailed Parameters:

Model

BT-ZL-80

(A~G)

BT-ZL-150

(A~G)

BT-ZL-225

(A~G)

BT-ZL-408

(A~G)

BT-ZL-608

(A~G)

BT-ZL -800

(A~G)

BT-ZL-1000

(A~G)

Inside size WxHxD (cm)40x50x4050x60x5050x75x6060x85x8080x95x80100x100x80100x100x100
Outside size WxHxD (cm)100x170x87105x175x97115x190x97135x195x115145x185x137145x210x130147x210x140
Temperature range-70℃~+100℃(150℃)
(A:+25℃ B:0℃ C:-20℃ D:-40℃ E:-50℃ F:-60℃ G:-70℃)
Humidity range20%~98%R.H.(10%-98%R.H/5%~98%R.H is the specific condition)
Accuracy/ uniformly±0.1℃;±0.1%R.H./ ±1.0℃;±3.0%R.H.
Accuracy / volatility±1.0℃;±2.0%R.H./ ±0.5℃;±2.0%R.H.
Heating / cooling timeAbout 4.0℃/min;about 1.0℃/min(5~10℃/mm is the specific condition)
Inside materialStainless steel SUS 304#
Insulation materialHigh-temperature high-density amino acid ethyl ester foam insulation materials,
Cooling systemAir-cooled/ single-stage compressor(-20℃) ,wind, water cooled/two-stage compressor(-40℃~-70℃)
protectioncompressor overload switch, high and low pressure protection switch, over-humidity-temperature protection switches, fuses, warning system
accessoriesrecorder(purchase),view window,50mm testing hole,PL lamp,clapboard,Dry and wet gauze ball
controllerTEMI300 digital controller from South Korea
compressorFrance Tecumceh
power1Φ 220VAC±10% 50/60Hz & 3Φ 380VAC±10% 50/60Hz

 

 

Features:

1.High-texture appearance, the surface handled through the matte stripes, and use of planar non-reactive handles, easy to operate, safe and reliable.
2.Rectangular complex glass window can be viewed the testing sample, windows with anti-sweat heater device that prevents water vapor condensation, and high-brightness PL light.
3.Double-insulated airtight container, which can effectively isolate the internal temperature of leakage.
4.With an external water supply system can be easy to supply water and automatically reuse.
5.Compressor circulatory system from French "Taikang", more effective removal of oil between the condenser and the capillary and use environmentally refrigerants (R23, R404, R507).
6.Controller imported LCD display screen can be displayed measuring values and setting the value and time.
7.Controller with multi-segment program edited, temperature and humidity can be controlled quickly (OUICK) or slope (SLOP).
8.Built-in mobile pulley easy to move and has a strong positioning screw fixed position
 

Standard:
1.International Electrotechnical Commission Standard:
IEC68-2-03_test method Ca_Steady damp-heat
IEC68-2-01_test method A_cold
IEC68-2-02_test method B_dry heat


2. Military Standards:
MIL-STD-810F-507.4 humidity
MIL-STD-810F-501.4 high temperature
MIL-STD-810F-502.4 low temperature
MIL-STD883C test method 1004.2 temperature and humidity cycling test
MIL-STD810D test method 502.2
MIL-STD810 test method 507.2 procedure 3


3. Japanese Industrial Standard:
JIS C60068-2-3-1987 test method Ca: Steady damp-heat
JIS C60068-2-2-1995 test method B:dry heat
JIS C60068-2-1-1995 test method A:low temperature


4. USA Semiconductor Industry Standard:
JESD22-A101-B-2004 Constant temperature and humidity test
JESD22-A103-C-2004 High Temperature Storage Test
JESD22-A119-2004 Low Temperature Storage Test


5. Chinese National Standard:
GB11158 Technical conditions for high-temperature testing box
GB10589-89 Technical conditions for low-temperature testing box
GB10592-89 Technical conditions for high and low temperature testing box
GB/T10586-89 technical conditions for humidity testing chamber
GB/T2423.1-2001 Low-temperature testing methods
GB/T2423.2-2001 High-temperature testing methods
GB/T2423.3-93 Testing Method for humidity Test Chamber
GB/T2423.4-93 Alternating hot and humid testing method
GB/T2423.22-2001temperature testing method


6. China's National Military Environment Test Equipment
GJB150.3 high-temperature testing
GJB150.4 low-temperature testing
GJB150.9 hot and humid condition testing

Company profile

 

 

Hot Products

Walk in Temperature Humidity Climatic Chamber Stability Lab Test Equipment Walk in Stability Chamber ...
Growth Medical Aging Equipment Environmental Temperature Humidity Climate Test Chamber Equipment ...
Land Type Medical product/aviation Electronic Accelerated Aging Test Chamber Product Description ...
Programmable PID Control Medical Temperature Humidity Test Chamber Constant climate chamber/ Mold ...
Limiting Oxygen Index Test Apparatus Electronic Product Description Specification Item Name Fully ...
Climate Chamber With Humidity Control Programmable Temperature & Humidity Test Chamber Electric ...