Home Companies Shanghai Korain Biotech Co., Ltd

Customized Mouse ELISA Kit 96 Wells For Accurate Quantitative Detection

Shanghai Korain Biotech Co., Ltd
Active Member

Contact Us

[China] country

Address: #1008.Junjiang Internatioanl Bldg. 228 Ningguo Rd. Yangpu Dist. Shanghai. 200090. China

Contact name:

Inquir Now

Shanghai Korain Biotech Co., Ltd

Customized Mouse ELISA Kit 96 Wells For Accurate Quantitative Detection

Country/Region china
City & Province shanghai shanghai
InquireNow

Product Details

96 Wells Customized Mouse VK2 ELISA Kit For Accurate Quantitative Detection

 

Cat.No E1804Mo

Standard Curve Range: 0.03nmol/L - 9nmol/L

Sensitivity: 0.011nmol/L

Size: 96 wells

 

Intended Use

This sandwich kit is for the accurate quantitative detection of Mouse Vitamin K2 (also known as VK2) in serum, plasma, cell culture supernates, cell lysates, tissue homogenates.

 

Assay Principle

This kit is an Enzyme-Linked Immunosorbent Assay (ELISA). The plate has been pre-coated with Mouse VK2 antibody. VK2 present in the sample is added and binds to antibodies coated on the wells. And then biotinylated Mouse VK2 Antibody is added and binds to VK2 in the sample. Then Streptavidin-HRP is added and binds to the Biotinylated VK2antibody. After incubation unbound Streptavidin-HRP is washed away during a washing step. Substrate solution is then added and color develops in proportion to the amount of Mouse VK2. The reaction is terminated by addition of acidic stop solution and absorbance is measured at 450 nm.

 

Reagent Provided

ComponentsQuantity
Standard Solution (9.6nmol/L)0.5ml x1
Pre-coated ELISA Plate12 * 8 well strips x1
Standard Diluent3ml x1
Streptavidin-HRP6ml x1
Stop Solution6ml x1
Substrate Solution A6ml x1
Substrate Solution B6ml x1
Wash Buffer Concentrate (30x)20ml x1
Biotinylated Mouse VK2 Antibody1ml x1
User Instruction1
Plate Sealer2 pics
Zipper bag1 pic

 

Specimen Collection

Serum Allow serum to clot for 10-20 minutes at room temperature. Centrifuge at 2000-3000 RPM for 20 minutes.

 

Plasma Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 15 minutes at 2000-3000 RPM at 2 - 8°C within 30 minutes of collection.

 

Urine Collect by sterile tube. Centrifuge at 2000-3000 RPM for approximately 20 minutes. When collecting pleuroperitoneal fluid and cerebrospinal fluid, please follow the procedures above-mentioned.

 

Cell Culture Supernatant Collect by sterile tubes when examining secrete components. Centrifuge at 2000-3000 RPM for approximately 20 minutes. Collect the supernatants carefully. When examining the components within the cell, use PBS (pH 7.2-7.4) to dilute cell suspension to the cell concentration of approximately 1 million/ml. Damage cells through repeated freeze-thaw cycles to let out the inside components. Centrifuge at 2000-3000 RPM for approximately 20 minutes.

 

Tissue other body fluids Rinse tissues in PBS (pH 7.4) to remove excess blood thoroughly and weigh before homogenization. Mince tissues and homogenize them in PBS (pH7.4) with a glass homogenizer on ice. Thaw at 2-8°C or freeze at -20°C. Centrifuge at 2000-3000 RPM for approximately 20 minutes.

 

*Sample can't be diluted with this kit. Owing to the the material we use to prepare the kit, the sample matrix interference may falsely depress the specificity and accuracy of the assay.

 

Reagent Preparation

All reagents should be brought to room temperature before use.

Standard Reconstitute the 120μl of the standard (9.6nmol/L) with 120μl of standard diluent to generate a 4.8nmol/L standard stock solution. Allow the standard to sit for 15 mins with gentle agitation prior to making dilutions. Prepare duplicate standard points by serially diluting the standard stock solution (4.8nmol/L) 1:2 with standard diluent to produce 2.4nmol/L, 1.2nmol/L, 0.6nmol/L and 0.3nmol/L solutions. Standard diluent serves as the zero standard(0 nmol/L). Any remaining solution should be frozen at -20℃ and used within one month. Dilution of standard solutions suggested are as follows:

 

4.8nmol/LStandard No.5120μl Original Standard + 120μl Standard Diluent
2.4nmol/LStandard No.4120μl Standard No.5 + 120μl Standard Diluent
1.2nmol/LStandard No.3120μl Standard No.4 + 120μl Standard Diluent
0.6nmol/LStandard No.2120μl Standard No.3 + 120μl Standard Diluent
0.3nmol/LStandard No.1120μl Standard No.2 + 120μl Standard Diluent

 

Standard ConcentrationStandard No.5Standard No.4Standard No.3Standard No.2Standard No.1
9.6nmol/L4.8nmol/L2.4nmol/L1.2nmol/L0.6nmol/L0.3nmol/L

 

Wash Buffer Dilute 20ml of Wash Buffer Concentrate 30x into deionized or distilled water to yield 500 ml of 1x Wash Buffer. If crystals have formed in the concentrate, mix gently until the crystals have completely dissolved.

 

Assay Procedure

1. Prepare all reagents, standard solutions and samples as instructed. Bring all reagents to room temperature before use. The assay is performed at room temperature.

2. Determine the number of strips required for the assay. Insert the strips in the frames for use. The unused strips should be stored at 2-8°C.

3. Add 50μl standard to standard well. Note: Don’t add antibody to standard well because the standard solution contains biotinylated antibody.

4. Add 40μl sample to sample wells and then add 10μl anti-VK2 antibody to sample wells, then add 50μl streptavidin-HRP to sample wells and standard wells (Not blank control well). Mix well. Cover the plate with a sealer. Incubate 60 minutes at 37°C.

5. Remove the sealer and wash the plate 5 times with wash buffer. Soak wells with at least 0.35 ml wash buffer for 30 seconds to 1 minute for each wash. For automated washing, aspirate all wells and wash 5 times with wash buffer, overfilling wells with wash buffer. Blot the plate onto paper towels or other absorbent material.

6. Add 50μl substrate solution A to each well and then add 50μl substrate solution B to each well. Incubate plate covered with a new sealer for 10 minutes at 37°C in the dark.

7. Add 50μl Stop Solution to each well, the blue color will change into yellow immediately.

8. Determine the optical density (OD value) of each well immediately using a microplate reader set to 450 nm within 10 minuets after adding the stop solution.

 

Calculation of Result

Construct a standard curve by plotting the average OD for each standard on the vertical (Y) axis against the concentration on the horizontal (X) axis and draw a best fit curve through the points on the graph. These calculations can be best performed with computer-based curve-fitting software and the best fit line can be determined by regression analysis.

Hot Products

High Specificity Mouse ELISA Kit High Precision Vitamin D3 Sandwich ELISA Kit Cat.No E0457Mo ...
96 Wells High Sensitivity and Specificity Mouse VD3 ELISA Kit With Oem Service Cat.No E0457Mo ...
Sandwich Type Mouse Vitamin D3 ELISA Kit Laboratory Research VD3 ELISA Kit Cat.No E0457Mo Standard ...
High Sensitivity and Specificity Mouse Vitamin K2 ELISA Kit 96 Wells Plate Customized Cat.No E1804Mo ...
96 Wells Customized Mouse VK2 ELISA Kit For Accurate Quantitative Detection Cat.No E1804Mo Standard ...
2 Hours Assay Length Mouse Vitamin K2 ELISA Kit Mouse High Specificity ELISA Kit Cat.No E1804Mo ...