Beijing Globalipl Development Co., Ltd. |
|
RF Cavitation Cryotherapy Body & Face Slimming Fat Removal Laser Equipment
Description
1. Cellulite reduction,skin tightening
2 Freeze handles working at the same time.
3. 4 Handles: 2 fat freeze, cavitation, RF
Working Theory
1. Cryolipolysis
Cryolipolysisis a non-invasive (without contact) procedure in which doctors
place a small suction cup on a patient's skin. The device gradually
extracts body heat until the subcutaneous fat is frozen.
During the procedure, the applicator delivers precisely controlled
cooling conditions that have been proven to target and eliminate
fat cells in specific areas of the body. When fat cells are exposed
to precise cooling, they trigger a process of natural removal that
gradually reduces the thickness of the fat layer.
Fat cells, according to researchers at Harvard Medical School, are
very sensitive to cold. They discovered that intense, localized
freezing killed adipocytes - the cells involved in forming fat
tissue. Therefore, cold destroys fat by damaging the cells: they
gradually die and are then naturally metabolized by lymphatic
system.
The cryolipolysis system controls the rate of energy extraction or
cooling during the procedure. The result is a reduction in fat
bulges that is visible in most patients in two to four months. The
fat cells in the treated area are gradually eliminated through the
body's normal metabolic processes.
The only drawback of cryotherapy treatments is that you can't see
the results immediately. It will take a few months for the entire
process to be completed, including metabolizing dead fat cells. The
procedure itself will last about an hour.
2. Cavitation
Ultrasonic cavitation slimming instrument (ultraound liposuction) adopts the latest
scientific and technology can be effective treatment for stubborn
cellulite and orange peel fat. An ultrasonic cavitation generator
is based on the resonance of pressure waves in continuous
transmission. This produces micro-bubbles that implode adipose
cells, destroying and processing of fat in a liquid substance,
which will be eliminated by the lymphatic system, urinary and
faecal route. This makes one believe that corporal remodeling,
because it redistributes the body cells that have not been
destroyed. So cavitation is effective to dissolve fat, improve
cellulite tissues, tighten skin, enhance skin elasticity and so on.
3. RF
Clinical practice has proved that RF can effectively compact and regenerate skin. Using the unique
deep-heating technology (radio frequency plasma technology), it can
active the deep collagen and promote new growing of collagen, to
fill collagen contraction and vacancy loss, thus to tighten skin
and recover skin elasticity.
Display
Parameters
Output Power: | 1000W | |
Display: | 8.4inch color touch screen | |
Language: | English | |
Dimension | 59*35*112.5cm | |
N.W: | 40kg | |
Package: | Aluminium box | |
Handpiece: | 5 pcs Handpiece | |
H1: Big fat freeze handle 18*8*6.8cm | ||
H2: Small fat freeze handle 15*6.3*5cm | ||
H3: Multipolar RF | ||
H4: Cavitation | ||
Pressure: | 400KPA | |
Temperature: | -10~5degree | |
Cooling system: | Wind+water+semiconductor | |
Working Time: | No downtime | |
Cavitation | Frequency: | 40 KHz |
Energy: | 1~50 W/cm2 | |
Mode | Pulse | |
Head Diameter | 50 mm | |
Multipolar RF | Frequency: | 6 MHz |
Energy: | 1~50 J/cm2 | |
Head Diameter: | 50 mm |
Features
1. Suitable treatments :All kind of skin
2. 2 fat freeze handles can be work together or separatly.
3. 8.4'' LCD Touch Screen, beautiful and easy operation.
4. Japanese Top-level Cooling plate, ensure steady cooling, good
effect, long life.
5. 24hours working without stop.
Security introduction
The cool fat reduction system is high‐tech medical equipment with safety and reliability, mainly for removing surplus fat, burning surplus fat, Lymphatic Treatment, skin tightening and improving skin elasticity. Etc. For using the machine safely, operators and assistants must know the security notice in this chapter. Most important, it’s the safest design for both treatments all are as following:
1. Automatically inspection system after turning on the machine
2. The probe adopts silicon rubber (to meet the medical requirements), offering comfortable feeling when touching skin during treatment
3. This machine is designed with separately security safe circuit. As electricity leakage, the electric circuit can be cut off.
4. Once emergency situation, the red button switch is used to turn off the power.
5. The key switch is to prevent anyone from operating the machine.
Warning
Without proper operation, any slimming machine may cause personal injury. Besides, there is high voltage in the machine's cooling process. Any one who operates the machine should pay alert attention the process, and follow the instruction to take protective measures.
Patients: It mainly depends on well trained doctor and appropriate setting treatment room of the patients' safety, however, the patients themselves' knowledge are also very important., better they should know the treatment theory.
About Us:
Mobile phone:86-13439681376
Website:www.globalipl.com