WRT Series 1A to 100A Transformer DC Resistance Tester

Introduction:

  • WRT Transformer DC Resistance Tester is used for testing, installing and exchanging the semi-finished or finished transformer.

  • WRT Transformer DC Resistance Tester is also a necessity for power department to do preventive trials.

  • WRT Transformer Winding Resistance Tester can effectively help you to find disfigurements in the manufacturing of transformer, such as the winding choosing, welding, loose joints, missing shares and hidden danger in the running.

  • In order to meet the need of fast measurement of DC resistance, our company makes use of our technological advantage to develop the Micro Ohmmeter;

 

Features:

  • WRT Transformer DC Resistance Tester is suitable for large-scale transformer above240MVA in temperature rising tests.

  • 840MVA transformer low-voltage direct-resistance tester completed within 2 minutes and the data is stable and accurate.

  • Dual-channel shows the measurement data at the same time.

  • Each interval of 60 seconds automatically print data.

  • Equipped with temperature conversion software, curve waveforms.

 

Parameters:

Item

WRT-2

WRT-10

WRT-20

WRT-40

WRT-100

WRT-20S

Test current

2A

10A

20A

40A

25A,50A, 100A

Single phase:1A,5A,10A,20A, 40A

Three phase: 1A, 5A, 10A, 20A

Measuring range

1μΩ~

4.5kohm

1μΩ~

20kohm

1μΩ~

10kohm

1μΩ~

10kohm

50μΩ-200mΩ(100A)

 

100μΩ-400 mΩ(50A)

 

200μΩ-800 mΩ(25A)

Single phase:

10mΩ~20Ω(1A)

1 mΩ~4Ω(5A)

1 mΩ~2Ω(10A)

1 mΩ~1Ω(20A)

1 mΩ~0.5Ω(40A)

 

Three-phase:

10 mΩ~6Ω (1A,each phase)

1 mΩ~1Ω (5A,each phase )

1 mΩ~0.6Ω (10A,each phase )

1 mΩ~0.3Ω (20A,each phase )

Resolution

1μΩ

Max. Error

0.2%RDG+2D

Voltage output

20V

Resolution

1μΩ

Power supply

AC220V±10%% 50Hz/60Hz

Working environment

-10℃-+40℃ RH≤85%

 
 

 

Real Picture:

Hot Products

TTR-I Single Phase and Three Phase Transformer Turns Ratio Tester Introduction: TTR-I Transformer ...
TTR-I 3 Phase Transformer Turns Ratio Test Set Introduction: TTR-I Transformer Turns Ratio Test Set ...
KFZ Power Transformer Parameters Testing Transformer Capacity Tester Introduction: KFZ Transformer ...
TDT Automatic Multi-functional Transformer 10kV Tan Delta Tester Introduction: TDT Transformer 10kV ...
WRT Series 1A to 100A Transformer DC Resistance Tester Introduction: WRT Transformer DC Resistance ...
TTR-I Transformer Turns Ratio Meter Introduction: TTR-I Transformer Turns Ratio Meter is designed ...