Home Companies Delta Technology (Chongqing) Co., Ltd.

JF-2004 Ultrasonic Sensor Detecting Transformer Partial Discharge Detector

Delta Technology (Chongqing) Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: No.85 Zhong Shan Yi Road, Yu Zhong District, Chongqing, China. 400010

Contact name:Tina Chen

Inquir Now

Delta Technology (Chongqing) Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

JF-2004 Ultrasonic Sensor Detecting Transformer Partial Discharge Detector

Country/Region china
City & Province chongqing chongqing
InquireNow

Product Details

JF-2004 Ultrasonic Sensor Detecting Transformer Partial Discharge Detector

Introduction:

  • JF-2004 Transformer Partial Discharge Detector is used for the detection and evaluation of the insulation status of high-voltage switchgear, ring network cabinets, transformers, GIS, overhead lines, cable terminals, cable branch boxes and other equipment.
  • Partial discharge intensity detection: By measuring the discharge signal within a power frequency period, the intensity of partial discharge is characterized according to the maximum value (dB) in the discharge pulse sequence.
  • Partial discharge frequency detection: The device measures the discharge signal within a power frequency period, extracts discharge pulses and characterizes the frequency of partial discharges according to the number of discharge pulses.

Standards:

  • ASTM: ASTM D2863
  • ISO: ISO 4589-2
  • NES: NES 714

Application Field:

  • Building Materials;
  • Wire&cable;
  • Upholstered furniture;
  • Others;

Features:

  • Configure different sensors to realize partial discharge detection of almost all electrical equipment;
  • Humanized man-machine interface facilitates data management of different devices, including traceback of historical data change trends, horizontal and vertical data analysis, and realizes 360 ° comprehensive diagnosis of the device under test;
  • Built-in ultrasonic sensors and transient ground voltage (hereinafter referred to as TEV) sensors, which can be connected with special sensors such as transformers, GIS, overhead lines and cables;
  • Adopt non-intrusive detection method, no power failure during the test, maybe no high voltage source is applied, which is more convenient to use than traditional pulsed partial discharge detector;
  • The test bandwidth range is 30kHz ~ 2.0GHz, suitable for the detection principle of various frequency bands;

 

Parameters:

Item NameJF-2004 Ultrasonic Sensor Detecting Transformer Partial Discharge Detector
Measuring range0-60 dBmV
Resolution±1dB
Maximum pulse per cycle1400
Measurement frequency3~100MHz
Display4.0 inch RGB LCD screen
ControllerARM
ConnectorUSB interface (also charger input) 3.5mm stereo headphone jack
External ultrasonic sensor input wireless wifi Wireless synchronization benchmark
SD cardstandard 16G
Earphoneminimum 8 ohm
Humidity20-85% relative humidity
Weight0.4KG(host)

 

JF-2004 Transformer Partial Discharge Detector Picture:

    Hot Products

    CPT-III 220V to 500kv Power Current Transformer Testing Equipment Introduction: CPT-III Power ...
    CPT-III 220V to 500kv Power Current Transformer Testing Equipment Introduction: CPT-III Current ...
    Jf-2004 Portable Switchgear and Transformer Partial Discharge Detector Introduction: JF-2004 ...
    JF-2004 Easy Use Portable Transformer Partial Discharge Detector Introduction: The detector is used ...
    JF-2004 Ultrasonic Sensor Detecting Transformer Partial Discharge Detector Introduction: JF-2004 ...
    Kfz Automatic Transformer Capacity Transformer Power Analyzer Kfz Transformer Capacity Transformer ...