EK keeps looking for valuable distributors and partners around international markets…

 

Clean Room double skin DX Air Handling Unit 30/50 mm PU insulation

 

 

Features of EK clean-room air handling unit EK clean-room air handling unit is specifically designed for clean rooms. It provides a built-in cooling and heating source, integrates air handling and automatic control functions, and has the following features: low investment, simple system, efficient running, and easy installation and maintenance.

 

■ The unit has a simple design and easy control, and is suitable for independent use.

 

■ The indoor unit can be directly mounted to the ceiling or in an attached room, not requiring a special air-conditioner room.

 

■ No chilled or cooling water system is required. The control is simple. The project can be completed phase by phase at a low construction cost.

 

■ The maintenance is simple. Maintenance of a single unit requires only the space of the clean room.

 

■ The unit can run at temperature ranging from -10°C to 48°C.


Specifications

 

ModelIndoor unitEKDX050-25A/ EKDX050-25AREKDX075-37.5A/ EKDX075-37.5AREKDX100-25A/ EKDX100-25AR

EKDX100

-50A/

EKDX100

-50AR

EKDX125-31A/ EKDX125-31AREKDX125-62.5A/ EKDX125-62.5AR
Outdoor unitEKAA100AB/ EKAA100ARBEKAA150AB/ EKAA150ARBEKAA100AB/ EKAA100ARB

2xEKAA

100AB/
2xEKAA

100ARB

EKAA125AB/ EKAA125ARB

2xEKAA

125AB/
2xEKAA

125ARB

Nominal cooling capacity (1)kW2537.525503162.5
Nominal heating capacity (1)kW2841.3285534.168
Nominal cooling capacity (2)kW--32.521442958
Nominal heating capacity (2)kW--3624493263
Air flowm3/h5000750010000100001250012500
EKDM air handling unit model corresponding to the external height and width EKDM0507HEKDM0510HEKDM0611HEKDM0611HEKDM0810HEKDM0810H
Refrigerant model R22
Outer dimensions of indoor unitLengthmmAs per the number of function sections
Heightmm8508501010101013301330
Widthmm117016501810181016501650
Outer dimensions of outdoor unit
(W × D × H)
mm

990x840

x1840

1290x840

x1840

990x840

x1840

2x990x840

x1840

990x840

x1840

2x990x840

x1840

Compressor of outdoor unitModelFully hermetic volute
Outdoor unit weightkg265 / 280285 / 300265 / 2802x265 / 2x280270 / 2852x270 / 2x285
Power supply of outdoor unit 380V/3N~/50HZ
Cooling input power of outdoor unitkW9.33 / 9.416.13 / 17.479.33 / 9.420.41 / 20.1712.1 / 12.2524.2 / 24.5
Heating input power of outdoor unitkW-- / 9.75-- / 14.7-- / 9.75-- / 20.3-- / 10-- / 20
Connecting pipe
specifications
Liquid pipe

φmm

(in.)

15.88(5/8)15.88(5/8)15.88(5/8)15.88(5/8)15.88(5/8)15.88(5/8)
Gas pipeφmm(in.)28.6(1-1/8)34.9(1-3/8)28.6(1-1/8)28.6(1-1/8)28.6(1-1/8)28.6(1-1/8)
Connect mode Soldering

 

Note:
■ The nominal cooling capacity (1) is measured under the following conditions: The indoor dry/wet bulb reads 27/19 °C and the outdoor dry/ wet bulb reads 35/24 °C. The nominal heating capacity (1) is measured under the following conditions: The indoor dry bulb reads 20 °C and the outdoor dry/wet bulb reads 7/6 °C.

 

■ The nominal cooling capacity (2) is measured under the following conditions: The indoor dry/wet bulb reads 24/17 °C and the outdoor dry/wet bulb reads 35/24 °C. The nominal heating capacity (2) is measured under the following conditions: The indoor dry bulb reads 24 °C and the outdoor dry/wet bulb reads 7/6 °C.

 

■ The nominal cooling capacity does not consider heat losses of the fan motor of the indoor unit. The external static pressure can be customized, in which case the power of the air supply motor changes accordingly.

 

■ The specifications are subject to change due to product improvements without prior notice.

 

■ The fresh air flow of the unit cannot be larger than 20%.


Consolidated Structure

 

The unit features a compact structure, easy assembly, and solid seal. It adopts special seal glue handling, providing air leakage rate as low as 0.3%. The 30mm (standard)/50mm (optional) enhanced high-pressure non-fluorine polyurethane double-layer foamed panel delivers a solid insulation performance and high bearing capacity, meeting requirements of a purifying unit for high residual pressure.

 

High Efficient and Low Noise

 

The outdoor unit adopts brand-name fully hermetic volute compressors that deliver high efficiency, low noise, and strong resistance to hydraulic shock and run at temperature ranging from -10°C to 48°C, meeting cleaning requirements in various regions and scenarios.

 

The indoor unit adopts imported high-quality centrifugal fans with double air intakes (model selection of the fans has passed AMCA certification) or unhoused fans (optional), and is equipped with dedicated anti-vibration measures for quiet running.

 

Load Matching

 

The evaporation section of the indoor unit can be equipped with a bypass valve. The direct evaporation coil supports combination with multiple cooling capacity options according to different conditions for a wide range of fresh air/air return scenarios. The outdoor unit of a large-capacity cooling unit adopts modular design, allowing differential energy regulation during use, lowering the operating cost, and reducing shock on the grid at startup.

 

Sterilization

 

The indoor unit adopts a dry water drainage tray that has no residual condensed water and prevents bacteria. A stainless steel water tray is optional. In addition, a sterilization device such as efficient UV sterilization lamp and ozone generator can be configured as required to eliminate bacteria and effectively
suppress microbes in the system.

 

Saving Investment

 

The unit has a built-in cooling and heating source and does not require a chilled or cooling water system, greatly saving user investment, and making the unit structure simple and compact. No dedicated equipment room is required. The unit can run immediately after cabling and piping. The installation, use, and maintenance are easy.

 

Smart Control

 

The unit adopts integrated digital electromechanical design and is equipped with a smart controller, providing multiple control functions such as constant temperature, constant humidity, function setting, fault alarm, and remote monitoring to ensure safe and reliable unit running.

 

Prevention of Cold Bridge

 

The unit adopts inner skeleton design and high-strength foam seals and tight repair door structure, effectively preventing cold bridge between wall plates, between wall plate and inner skeleton,
or at the repair door. The panel of the unit is wrapped with solid insulating UPVC plastic at all sides, avoiding direct contact with thermal conductive parts, providing T1 class insulation performance, eliminating cold bridge, and preventing cooling loss.

 

High-Quality Filters

 

The unit adopts a high-quality multi-level (primary, medium, sub-high, and high efficiency) air filtering system. The filtering class meets the requirements of a special clean room, and can effectively suppress organic compounds on the filtering paper.

 

Purification Design

 

A special frame structure ensures smooth surface in the unit. The inner stainless steel surface and an efficient heat exchanger (optional) made of hydrophilic aluminum foil can effectively prevent dust accumulation and re-entrainment. The special design and materials can resist disinfectant and air erosion and are favorable for regular cleaning and sterilization.

 

Multi-System Design

 

The outdoor unit adopts modular design and starts level by level, efficiently reducing shock on the grid. Multiple levels of cooling are provided, allowing differential energy regulation under different load conditions and reducing the operating cost. The compressors wear in a balanced manner, prolonging the lifecycle.

Hot Products

EK keeps looking for valuable distributors and partners around international markets… Low Noise ...
EK keeps looking for valuable distributors and partners around international markets… Vertical type ...
EK keeps looking for valuable distributors and partners around international markets… Horizontal ...
EK keeps looking for valuable distributors and partners around international markets… Plate heat ...
EK keeps looking for valuable distributors and partners around international markets… Clean Room ...
EK keeps looking for valuable distributors and partners around international markets… 50 mm PU ...