Using our company's SVG dynamic reactive power compensation device,
in order to improve the power system stability, increase the
transmission capacity, eliminate reactive power impact, filter the
harmonic, and balance three-phase voltage.
Installing our SVG dynamic reactive power compensation devices can
perform the following functions:
(1) Enhance the transmission capability
Installing SVG dynamic reactive power compensation device in long
distance transmission line, can not only compensate lines’ reactive
power, stable voltage, improve the effective transmission capacity
in normal operation condition, but also do a timely reactive power
regulation, damp system oscillations, enhance power system
stability in the event of a system failure.
(2) Maintain the electrical voltage, and strengthen the system
voltage stability
The load center, which has a large load capacity,without large
reactive power support, is easy to cause power grid voltage lower
and even lead to voltage collapse accidents. SVG dynamic reactive
power compensation device has the advantage of rapid reactive power
regulation, can maintain the load side voltage, and improve the
voltage stability of load side power supply system.
(3) Compensate system’s reactive power, improve power factor,
reduce the line loss, and save energy
Many loads of power distribution system such as asynchronous
motors, induction furnace and large capacity rectifier equipment,
electric locomotive etc, performed inductive in operation, consume
a large amount of reactive power, increase the electric energy loss
of the supply line, and decrease the voltage quality, and the
reactive current reduce the effective utilization rate of hair,
transmission, power supply equipment at the same time; For power
users, and low power factor will increase the charge of
electricity, increase the loss of transformer, and increase the
cost of production.
SVG can follow reactive changes of the load, achieve the dynamic
compensation of reactive power, minimize the line loss, and fully
improve the utilization rate of hair, transportation, and supply
electrical equipments.
(4) Suppress the voltage fluctuation and flicker
Nonlinear loads, such as electric arc furnaces, rolling mills,
electric railways etc, and the rapid change of the load may cause
voltage fluctuation and flicker, which cannot meet the user’s
requirements for voltage quality, can lead to bad performance of
equipment operation, occur over current, overheat, protection
device malfunction and equipment burnout accident, and affect the
equipment performance, production efficiency and product quality.
Voltage fluctuation and flicker is very bad to the safety of
production and human health
(5) Inhibit three-phase unbalance
SVG dynamic reactive power compensation device can rapidly
compensate negative sequence current generated by unbalanced load,
ensure that the three-phase current flowed into the power grid
always balance, greatly improve the power quality of electric
energy.
(6) Other multiple compensation functions
① Application for power grid
Inhibit the oscillation of the system; improve the stability of
power grid, and guarantee the safety of power grid.
As the regional power network becomes larger and larger, the
compensation device’s capacity is required to increase accordingly.
In hundreds of megabytes of level of the reactive power
compensation system, commonly
used program is to combine SVG with SVC, give full play to the
SVG’s quick characteristics, and make the system optimal in
compensation characteristic, cost, reliability and other aspects.
② Multiple compensation functions facing mill, electric arc
furnace, electric railway etc:
Compensate Load reactive power -- improve power factor, to be the
most effective flicker suppression device.
Compensate Load reactive power and harmonic -- compensate the
reactive power as well as the harmonic.
Compensate Load the three-phase unbalance -- the most effective
negative sequence current suppression device. Compensate Load
reactive power, harmonic and three-phase unbalance,not only
compensates reactive power, but also compensates harmonics and
three-phase unbalanced, and is the perfect solution for Load power
quality problem.