3.5 Inch Automated Vital Sign Machine , Patient Heart Monitor / Icu Patient Monitoring

Country/Region china
City & Province beijing beijing
Categories Payment Kiosks
InquireNow

Product Details

 

 

 

3.5 Inch LCD Display Portable Multi Parameter Patient Monitor

 

 

 

State (Beijing) Medical Technology Co., Ltd. established in 2002, is a High-tech medical products enterprise combining R&D, production ,sales and after-sale together, specialized in Medical Ultrasonic Instruments, ENT Workstation, Medical Endoscope Imaging Systems, Colposcope, Spectral Instrument for gynecology, Plasma Air Disinfection Machine, X-ray machines and other medical equipment. We constantly develop high-quality electric medical devices by adopting the domestic advanced technical facilities to blend the computer information process technology and clinical medicine research perfectly.

 

General parameters

 

Application occasionWidely used in hospital outpatient department, ward (such as high dependency ward , coronary care unit, neonatal intensive care unit, operating room and general wards of each departments) and ambulance ect.
Suitable peopleAdult, children, infant (BP parameters only apply to adult.)
Security classificationClass I, with inner power device.
Applied partsBF type CF TYPE
Operation modeContinuous operation
Product structureportable type
Power supplyAC 110V~230V±10% 50Hz/60Hz±2%
Network interfaceextendable
 

 

(ECG)

 

standard five leads connectionRed:R Yellow:L Green:F Black:N White:C
Overload protection1V minimum 1V
Measurement modeDiagnosis mode,monitor mode,surgical mode
Respiration,Lead off condition detected and active noise suppressionActive lead of DC current≤0.1μA
The current jointed by electrode for any other patients≤1μA
Lead off detected waveformU=2V I=0.04uA
active noise suppressionthe electric current which don’t apply to the body of patients.
Tall T -wave suppression1.4mV
QRS wave detectedRange(p-v RTI)not less than 0.5~5mV
Width(adult)Not less than 70~120ms
WIDTH(newborn/children)Not less than 40~120ms
No response for the following signalsRange(p-v RTI)no response under0.15mV

Width when the range is 1mv

 

no response under 10ms
Power frequency voltage tolerance(p-v RTI)≥100μV
Drift tolerance(0.1HZ signal superimposes on a bunch of QRS WAVEwhen the triangular wave signal of 0.1HZ,4MV superimposes on the wave signal of 05.mv, 100ms, 80bpm, heart rate display accuracy:80bpm.
Averaging calculation method of Heart rateaveraging by taking 4-12 R wave cycles
Heart rate display refresh rate1s
Responsive time of heart rate changes

80-120 BPM:Range 4-7 seconds

average 6 seconds

80-40 BPM: Range 4-7 seconds

average 6 seconds

 

The range and accuracy of heart rate meterRange(adult)not less than 30-200 bpm
Range(newborn/children)not less than 30-250 bpm
error≤±10%
Repetition rate=300 bpm( adult mode) signal display heart rate300 bpm
Repetition rate=350 bpm(newborn/children mode)signal display heart rate350 bpm
Alarm rangeUpper limit(adult)not less than 100-200bpm
Upper limit(newborn/children)not less than 100-250bpm
lower limit(adult/newborn/children)not less than 30-100bpm
Alarm resolution≤±10%
The limit error of alarm≤±10%
The startup time of cardiac arrest alarm≤10s
The startup time of the low heart rate alarm≤10s
The startup time of the high heart rate alarm≤10s
Alarm silentProvide silent and restart setup
Alarm is prohibitedDisplay alarm be prohibited
Input dynamic rangeInput signal range±5mV
speed rate(RTI)≤320mV/s
DC offset voltage-300~+300 mV
Input signal changes≤±10%
display can’t -work (display previous attenuation degree )≤50%
Input impedance:signal attenuation(0.67HZ~40HZ)≤20%
System noise(p-v RTI)≤30μV
multi-channel crosstalk: No signal channel gets disturbed by signaled channel≤5%
Gain select5mm/mv,10mm/mv At least having the gain select of 5mm/mv, 10mm/mv
Gain control methodsManual switch
Gain stabilityGain change per minute≤0.66%/min
Total change of gain within 1 hour≤±10%
Benchmark choice and accuracy of timeTime benchmarkAt least having 25mm/s time benchmark choice
The biggest error of time benchmark≤±10%
Output display the width of channelAt least having a channel whose width is 30mm
Output display aspect ratio10mm/mv 25mm/s AT least with aspect ratio of 0.4s/mv gear. The corresponding gain and time benchmark respectively are 10mm/mv and 25mm/mv.
Typical minimum input slew rate50V/s RTI
The accuracy of the reconstruction of the input signalTotal error of system≤±20%
Frequency responsea) Sine-inputUnder all the modes of 0.67-40hz attenuation:-3bm, upper limit:110%
b)Input 20ms-width trangle wave response0~25% The attenuation value of the wave crest:0-25%
To the response of the 0.3mv.s impact out of the rangeshift≤0.1mV
Slope rate≤0.30mV/s
Electrode weighing factor≥±5%
Lag effect of drifting 15mm≤0.5mm
Calibration voltage1mv 1hz squire signal Error≤±10%
Commo mode rejection≤1mV
The baseline control and stabilityRecovery time after reset≤3s
The drifting rate within 10 seconds≤10μV/s
baseline drifting within 1h≤500μV
Baseline drift under the working temperature≤50μV/℃
The display ability of the pacemaker pulse≥0.2mV
Electric surgical interference suppression: The Heart rate variation compared with before disturbance.≤±10%
protectionIsolation pressure- tolerant 4000V/50HZ,Anti-electric surgical interference, anti-defibrillation protection
Recovery time after defibrillationECG waveform recovery to baseline within 5s under the mode of monitor and surgery.
Recovery time after defibrillation(electrode polarization)ECG waveform recovery to baseline within 10s under the mode of monitor and surgery.
Recovery time to the electric surgical interferenceECG waveform recovery to baseline within 10s under the mode of monitor and surgery.
No overshoot pacemaker suppression
Range±2mV~±700mV,Pulse width 0.1ms~2msQRSwaveinstrument display
a) a single pacemaker pulseNo display
b)with the normal pacemaker of QRS-T pacemaker pulse6060±2bpm
3030±2bpm
0--
c)with the ineffective pacemaker of QRS mode pacemaker pulse.In all situations,overshoot should be less than 5% the range of pacemaker and the settling time of the overshoot must less than 5μs .Rising and falling time should be 10% of the pulse width , but can’t greater than 100μs,Besides the starting moment of the pacemaker pulse should before the starting moment of QRS composite wave.no suppression, don’t for reference
when the ventricular atrial pacemaker pulse has the same range and duration time with the ventricular pacemaker pulse above-mentioned,also ahead of ventricle pacemaker pulse 150ms to 250ms.No suppression, don’t for reference

 

Hot Products

Doctor Diagnose ICU CCU Monitor Multi Parameter Patient Monitor Out size: 36*18*33cm Package ...
Cheap price Portable Multi Parameter Patient Monitor with CE Product description STT-601B Multi...
Cheapest Multi Parameter Patient Monitor Doctor Diagnose Monitor Battery Battery type rechargeable ...
CE proved 2.8KG Portable Multi Parameter Patient Monitor 90VA Basic parameters Model STT-601C ...
3.5 Inch LCD Display Portable Multi Parameter Patient Monitor State (Beijing) Medical Technology Co....
Mobile Multi Parameter Patient Monitor 3.5 inch LED Display 90VA Basic parameters Model STT15-MPM43 ...