Home Companies Foshan Top One Power Technology Co.,Ltd.

CE & FCC 6kw Single output off grid solar inverter 48vdc 220vac frequency inverter for solar power system

Foshan Top One Power Technology Co.,Ltd.
Active Member

Contact Us

[China] country

Address: Add: 5/F, Bldg.2,,No.117 Zhangchayi Road, Chancheng Dist, Foshan, Guangdong, China

Contact name:Henry Lee

Inquir Now

Foshan Top One Power Technology Co.,Ltd.

CE & FCC 6kw Single output off grid solar inverter 48vdc 220vac frequency inverter for solar power system

Country/Region china
City & Province foshan guangdong
Categories Inverters & Converters
InquireNow

Product Details

CE & FCC 6kw Single output off grid solar inverter 48vdc 220vac frequency inverter for solar power system

Model : GI-60248

 

 

An individual 64-bit DSP control chip, more text samples and control functions

The detection and control program is written into the DSP chip. The results are fetched by DSP chip and the Power inverter is controlled by DSP chip. The advantage is that the value is accurate(by effective value). Tolerance is less than 0.01%

 

Photoelectricity isolation circuitry technology:

It can detect and modulate the pulse width of boost circuit, reduce the EFT(Electric Fast Transient) and raise anti-interference.

B.The Power inverter without this function. Which will cause high EFT(Electric Fast Transient) and low anti-interference.

 

The whole series with automatic AC charger and automatic AC mains switch function. Switch time within 4ms.

 

 

GI Series Low Frequency Pure Sine Wave Inverter (220V)
ModelGI-102GI-152GI-202GI-302GI-402GI-502GI-602
Rated Power1KW1.5KW2KW3KW4KW5KW6KW
Peak Power3KW4.5KW6KW9KW12KW15KW18KW
Nominal battery voltage12/24VDC12/24/48VDC24VDC/48VDC
InputDC input range10.5-15VDC (12V) / 21-30VDC (24V) / 42-60VDC (48V)
AC Mains input range170-275VAC (220/230/240VAC)±4%
AC input frequency50Hz: 45-65Hz / 60Hz: 55-65Hz±0.5Hz (50Hz/60Hz automatic recognition)
ProtectionLow battery alarm≤10.5VDC (12V) / ≤21VDC (24V) / ≤42VDC (48V) alarm
Low battery protection≤10VDC (12V) / ≤20VDC (24V) / ≤40VDC (48V) automatic shutdown
High battery alarm≥15VDC (12V) / ≥30VDC (24V) / ≥60VDC (48V) alarm
High battery protection≥17VDC (12V) / ≥34VDC (24V) / ≥68VDC (48V) automatic shutdown
Over load protection110%<loading<150%, shutdown after 60s alarm, loading>150%, shutdown after 20s alarm
High temperatureBuilt-in temperature real time sensor, ≥85℃ alarm, ≥90℃ automatic shutdown
Short circuit protectionAutomatic shutdown
OutputTransfer efficiency≥92%
Output voltage(DC battery mode) 220/230/240VAC±2%
Output frequency(DC battery mode) 60/50Hz±1%
Output wave formPure sine wave
Output voltage(AC mains mode) stable 220/230/240VAC±10% output (built-in AVR stablizer)
AVR output stablizerAC mains<170VAC±5% swtich to DC battery mode, AC mains>180VAC ±5% return to AC mains mode;
AC mains>275VAC±5% swtich to DC battery mode, AC mains<255VAC ±5% return to AC mains mode;
The above is for output 220V system reference, 230V/240V output just multiply by percentage
Output frequency(AC mains mode) automatic tracing from AC input
OtherTransfer time≤4ms
DisplayLCD Display with function buttons
Cooling systemIntelligent cooling fan control system
≤42℃ slow fan, ≥45℃ fast fan
AC Charger7 battery types modeGel U.S.A. / Gel European / A.G.M.1 / A.G.M.2 / Sealed lead acid / Open lead acid / Calcium(open) /
Deep sulphation cycle 15.5 for 4 hrs
AC charging Voltage13.6-14.2VDC(12V)/27.2-28.4VDC(24V)/54.4-56.8VDC(48V)
AC charging current0-35A: 5A / 10A / 20A / 25A / 30A / 35A, 6 stages adjustable option
3 Stages chargingBoost charging, direct charging, float charging
AC over charge protectionBattery voltage ≧16VDC (12V) ≧32VDC (24V) ≧64VDC (48V), stop charging after 60s alarm
Working mode
(Optional)
01AC mains priority
Always use AC mains as priority input to provide AC output and automatically charge the battery, only
stops charging when battery is fully charged, and only starts DC to AC converting untill AC mains is off
02Energy saving
Loading≤10% automatic shutdown, loading≥11%-100% automatic turn on
03DC battery priority
Always use DC battery as priority input to provide AC output, for 12V system, when battery≥13V, starts
DC to AC converting; when battery≤10.5V during converting, switch to AC mains mode to provide AC
output and automatically start charging the battery (for 24V/48V system, multiply by 2/4 accordingly)
ComnunicationRS-232/USB/SNMP(additional option)
EnvironmentTemperature-20~75℃
Humidity<95%
AppearanceProduct size (mm)430*310*270mm600*270*200mm
Packing size (mm)540*350*300mm720*310*270mm
Net Weight (kg)15kg17kg24.5kg29kg44kg48.1kg49.5kg
Gross Weight (kg)16.5kg19kg27kg31kg46kg50.1kg52.2kg
*Product specifications are subject to change without further notice

 

 

 

 

 

 

 

 

 

Question & Answer:

 

Q: How to choose a right Power inverter?

A:Tell us your demand, then our sales will recommend a suitable Power inverter to you.

 

Q: What's the different between Power inverter and solar Power inverter?

A: Power inverter is only accept AC input, but solar Power inverter not only accept AC input but also can connect with solar panel to accept PV input, it more save power.

 

Q: How about the delivery time?

A: 5 days for sample; 20 days for bulk order.

 

Q: What is the warranty of Power inverter?

A: One year warranty.

 

Q: How to solve the technical problem?

A: 24 hours after-service consultancy just for you and to make your problem to solve easily.

 

Hot Products

dc ac off grid solar inverter pure sine wave 48v to 220v 4000w home inverter for all kinds of ...
DC/AC Inverters off grid inverter single output solar power 24 volt inverter with 1 years warranty ...
Low frequency pure sine wave off grid solar inverter solar power 48 volt dc to 220 volt 50hz ac ...
High efficiency off grid inverter single output UPS 24v/48v to 220v/230v/240v dc to ac inverter ...
CE & FCC 6kw Single output off grid solar inverter 48vdc 220vac frequency inverter for solar power ...