Home Companies Xi'an Desun Uniwill Electronic Technology Co., Ltd.

PPM Electrode Optical Dissolved Oxygen Sensor , 12V Optical Do Probe Temperature

Xi'an Desun Uniwill Electronic Technology Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: Room 502, Unit 2, Building 1, Yi Cui yuan i city, No. 11, Tangyan South Road, Yanta District, Xi'an city, Shaanxi Province, China.

Contact name:Wang

Inquir Now

Xi'an Desun Uniwill Electronic Technology Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

PPM Electrode Optical Dissolved Oxygen Sensor , 12V Optical Do Probe Temperature

Country/Region china
City & Province Shaanxi
Categories Solar Chargers
InquireNow

Product Details

PPM Dissolved Oxygen Analyzer Electrode Dissolved Oxygen Sensor Do Sensor Probe Temperature

 

Technical Parameters

 

ItemParameters
ModelDS380
PrincipleFluorescence analysis method
Measuring range0~20mg/L or 0-200% saturation
Response time3 sec
Accuracy1%
Protection levelIP68
InstallationSubmersible
Temperature sensorNTC
Temperature range0~50°C
Temperature accuracy±0.2°C
OutputSupport RS-485, MODBUS protocol
Power supplyDC 6~12V, current <50mA
SizeΦ26*155 mm
Probe cable lengthDefault 5 m, customized 10m, 15 m and 30 m cable
Fluorescent cap life1 year
Maximum working pressure6bar
product materialPOM/SS316/Titanium alloy
Calibration methodOne or Two-point calibration
Power consumption< 0.5 W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maintenance schedule

 

Unlike the electrochemically-dissolved oxygen probe technology, the fluori-dissolved oxygen probe does not consume oxygen and does not require frequent cleaning (except when applied to viscous liquids).

 

Maintenance tasksRecommended maintenance frequency
Cleaning sensorClean every 30 days
Check sensor and fluorescent cap for damage

Check every 30 days

 

Replace the fluorescent capChange once a year

Calibrate the sensor

(if required by the competent authority)

According to the maintenance schedule required by

the competent authority

 

 

 

 

 

 

 

 

 

 

Note:

 

The maintenance frequency in the above table is only a recommendation. Please maintain the sensor according to the actual usage of the sensor. However, the replacement of the fluorescent cap is recommended to be replaced once a year.

 

Feedback from customers

 

Hot Products

High Precision Optical Water Do Sensor 20mg Aquaculture Industrial SS316 DS- 380 dissolved oxygen ...
PPM Dissolved Oxygen Analyzer Electrode Dissolved Oxygen Sensor Do Sensor Probe Temperature ...
Digital Aquaculture Water Optical Do Sensor Online With Fluorescent Cap This series optical ...
Optical Titanium Dissolved Oxygen Sensor For Seawater Farms Optical In line Probes Hand Wash Sensor ...
Online Optical Dissolved Oxygen Detector probe Pond DO Water Quality Monitoring Main Features Ø The ...
Product Description Portable Luminescent Dissolved Oxygen Meter DO Meter Oxygen Meter O2 Analyzer ...