Home Companies Xi'an Desun Uniwill Electronic Technology Co., Ltd.

Wastewater Treatment Digital PH Sensor 14pH , PH Sensor Temperature Compensation

Xi'an Desun Uniwill Electronic Technology Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: Room 502, Unit 2, Building 1, Yi Cui yuan i city, No. 11, Tangyan South Road, Yanta District, Xi'an city, Shaanxi Province, China.

Contact name:Wang

Inquir Now

Xi'an Desun Uniwill Electronic Technology Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Wastewater Treatment Digital PH Sensor 14pH , PH Sensor Temperature Compensation

Country/Region china
City & Province Shaanxi
Categories Water Treatment
InquireNow

Product Details

Wastewater Treatment PH Probe, PH Sensor Temperature Compensation

Product Description

Our digital pH sensor adopts industrial online electrode and built-in temperature sensor, which can automatically compensate for temperature, which is suitable for online long- term monitoring environment. The sensor adopts RS485 output and supports Modbus, which can realize networking and system integration without a controller.

 

Features

Range: 0-14 pH Accuracy: 0.1pH

0 ~ 50 ℃; IP68 protection, water depth within 10 meters

Built-in temperature sensor, automatic temperature compensation Digital sensor, support RS-485, MODBUS protocol

Adopt high-performance industrial online electrode, can work stably for a long time


Dimensions Technical parameter

Model
Online digital PH sensor
Measuring Range
0~14pH
<Response time
<30 sec
Precision
0.01Ph
Temperature range
0~ 50°C
Calibration method
Three-point calibration

 

output method
Support RS-485, MODBUS protocol
Housing diameter
26mm
Housing length
167.5
Cable length
5 meters (default), can be customized
power supply
DC 6~12V, current <50mA
Protection level
IP68
Housing Material
POM

 

Maintenance schedule

It is recommended to periodically calibrate or clean the sensor surface according to the actual application scenario. The calibration sequence for the three-point calibration is that the first point calibration is at pH 4.0, the second point calibration is at pH 6.86, and the third point calibration is at pH 9.18 in a buffer solution. Refer to the MODBUS document for specific calibration methods.

 

Maintenance tasks,Recommended maintenance frequency
Calibrate the sensor (if required by the competent authority)According to the maintenance schedule required by the competent authority

Sensor maintenance

  • External surface of the sensor: Wash the external surface of the sensor with tap water. If debris remains, wipe it with a moist soft cloth.
  • Check the cable of the sensor: The cable should not be tight during normal work, otherwise the internal wires of the cable will be easily broken and the sensor will not work properly.
  • Sensor storage: When the sensor is not in use, you should fasten the black plastic cap and check whether the sponge inside is wet. If it is not wet enough, please add 3mol / L potassium chloride solution and let the electrode be stored in the solution with potassium chloride.
Our Service

* Standardized workshop and process
* Strict professional quality inspection
* Return is supported if the product is unqualified.
* Fast delivery
* Warranty for 1 years

We are committed to the water quality monitoring industry, actively innovating and improving products, and optimizing industry application solutions. We take technology and quality as the cornerstone, honesty and service as the foundation, do a good job of water quality monitoring with our heart, and contribute to the development of the water quality monitoring industry. power. At present, the products are sold to more than 30 countries and regions overseas, and they have established their own sales network locally, cooperate with after-sales and maintenance personnel, and continue to supply water body monitoring equipment.

FAQ

Q: Is your company a manufacturer??
A: Yes,we are a professional manufacturer of online water quality monitoring products: oil in water sensor/ DO sensor/ NH4-N sensor / ORP / COD sensor / Blue-green algae sensor /Conductivity sensor /TDS / TSS /MLSS,ect.
Q: What parameters do you need for product selection?
A: Application, Range, Power supply and Output signal.
Q: How about the quality of the managements?
A: We have a complete quality control system, our products will be fully pre-inspection before shipping to you. We have the certification of ISO, CE, we could send the certification test of our company to you.
Q: Can you offer OEM services?
A: Yes,we support OEM and ODM products according to your requirements.
Q: What are your terms of payment and delivery time?
A: We could accept T/T, Paypal, Western Union, Credit Assurance. Generally, we will arrange the shipment within 7 days after received payment.
Q: How about warranty?
A: 12 months warranty

Hot Products

Wastewater Ph Probe Ph Electrode Probe Ph Probe Temperature Compensation Water Quality Monitor ...
Wastewater Treatment PH Probe, PH Sensor Temperature Compensation Product Description Our digital pH ...
Swimming Pool Ph Electrode High Temperature Ph Probe Glass Electrode Ph Meter Product Description ...
Industrial Online Ph Electrode Pure Warter Treament Ph Sensor probe Product Description The digital ...
Water EC sensor portable measurement conductivity tester,ph ec probe meter Agricultural PRODUCT ...
Four-Electrode Digital Conductivity Sensor Provides Accurate Temperature And Readings Of Conductivit...