Home Companies Xi'an Desun Uniwill Electronic Technology Co., Ltd.

Chemical Oxygen Demand Waste Water Treatment RS485 Online COD BOD Sensor

Xi'an Desun Uniwill Electronic Technology Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: Room 502, Unit 2, Building 1, Yi Cui yuan i city, No. 11, Tangyan South Road, Yanta District, Xi'an city, Shaanxi Province, China.

Contact name:Wang

Inquir Now

Xi'an Desun Uniwill Electronic Technology Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Chemical Oxygen Demand Waste Water Treatment RS485 Online COD BOD Sensor

Country/Region china
City & Province Shaanxi
Categories Water Treatment
InquireNow

Product Details

Chemical Oxygen Demand Waste Water Treatment RS485 Online COD BOD Sensor

 

 

There are different types of COD, BOD, and TSS analyzers available, each with its own strengths and weaknesses. For example, some analyzers use ultraviolet light to measure COD and BOD, while others use chemical reagents. TSS analyzers may use optical sensors or turbidity meters to measure the level of suspended solids.

 

One of the benefits of COD, BOD, and TSS analyzers is that they can help to reduce the number of chemicals and energy used in the treatment process. By providing real-time data on the quality of the water, operators can optimize the treatment process to minimize the use of chemicals and energy while still ensuring that the water meets regulatory requirements.

 

The optical method online COD sensor (Chemical oxygen demand sensor) is more economical and environmentally friendly than the traditional chemical method. Small in size, easy to install, and can be used for continuous online water quality monitoring. Automatic compensation for turbidity disturbances, with automatic cleaning device, optional titanium alloy (corrosion resistant).

 

COD sensors are mainly used for monitoring rivers, lakes, sewage, and other types of surface water, etc., and can be easily integrated into water quality monitoring systems to meet customer needs.

 

COD Analyzer

* Digital sensor, RS-485 output, support MODBUS

* No reagents, no pollution, more economical and environmentally friendly
* Can measure SAC, COD, TOC, and other parameters
* Automatic compensation for turbidity interference for excellent test performance

 

 

Product nameCOD sensor
Detection principleUV245nm UV Optics
Measurement range
DS500
(6 mm gap)
COD 0 ~ 500 mg/lL
TSS 0~600 mg/L
BOD 0~300 mg / L
Measurement range
DS500
(6 mm gap)
COD 0 ~ 2000 mg/lL
TSS 0~1000 mg/L
BOD 0~1000 mg / L
Measurement range
DS501
(1 mm gap)
COD 6000~10000 mg/lL
TSS 0~5000 mg/L
BOD 0~5000 mg / L
Measurement accuracy±5%
Resolution0.01mg/L
Optical path1mm,6mm,10mm
Temperature range0~45℃
Stored temperature-40~80℃
Output signalRS-485, MODBUS protocol
Calibration method1 or 2 points
Automatic cleaningBuilt-in cleaning brush
Waterproof levelIP68
Under pressure1bar
Product material316/POM/Titanium alloy
Product Size∅46×218mm
Power informationDC 6~12V,Current <10mA
Cable lengthStandard 5 meters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Online COD BOD Sensor Waste Water Treatment RS485 Chemical Oxygen Demand COD BOD Tester

 

Desun Uniwill Water quality sensors are designed to provide accurate and reliable measurements of water quality parameters, allowing for effective monitoring and management of water resources. They are commonly used in various industries and applications, including environmental monitoring, water treatment plants, aquaculture, industrial processes, and research laboratories.

 


FAQ

 

1. What parameters do you need for product selection?
A: Application, Range, Power supply and Output signal.

2. Is your company a manufacturer?
A: Yes, we are a professional manufacturer of water quality monitoring products.

3. Can you offer OEM/ODM services?
A: Yes, we support OEM and ODM products according to your requirements.

4. Can you send samples?
A: Yes, all product can be send the samples for testing.

5. Do your products have certification?
A: Yes, We have the certification of ISO, CE and send the test report of our company to you.

6. How about the quality of the management?
A: We have a complete quality control system, all products will be test before shipping to you.

7. What are your terms of payment and delivery time?
A: We could accept T/T, Paypal, Western Union, and Credit Assurance. Generally, we will arrange the shipment within 7 days after receiving payment.
8. How about warranty?
A: 12 months warranty

9. Do you provide LOT system service?
A:Yes, our industrial controllers can have built-in lot modules for real-time data transfer to the cloud.all of our sensors can be directly connected to the lot module for data transfer and remote monitoring

 

Hot Products

Online RS485 COD BOD TOC Sensor Chemical Oxygen Demand Probe for Waste Water Treatment Water quality ...
Online COD BOD Sensor Waste Water Treatment RS485 Chemical Oxygen Demand COD BOD Tester Online COD ...
Hot Sale online Bod Cod TSS Sensor For Sewage Treatment Plant COD is a measure of the amount of ...
RS485 Output BOD TOC COD Probe Supplier Chemical Oxygen Demand Sensors and COD Analyzer for Water ...
Chemical Oxygen Demand Waste Water Treatment RS485 Online COD BOD Sensor There are different types ...
RS485 Output BOD TOC COD Probe Supplier Chemical Oxygen Demand Sensors and COD Analyzer for Water ...