Nanchang YiLi Medical Instrument Co.,LTD |
Verified Suppliers
|
|
Cuffed Trachostomy Tube Anesthesia Products With Balloon Non Fenestrated
Tracheostomy tube is used to create an opening in neck ( windpipe) to breath oxygen without month or nose. Trach tube is often used in obvious respiratory difficulty condition, and the cause can not be relieved quickly.
Components: Cannula, Inserting Stylet, Balloon, Tie band holder
Size: #4.0mm, #4.5mm, #5.0mm, #5.5mm,#6.0mm, #6.5mm, #7.0mm, #7.5mm, #8.0mm, #8.5mm, #9.0mm, #10.0mm
Features & Advantages:
1. Made from medical grade PVC, NON toxic
2. Evenly balloon, high volume low pressure
3. Opaque line through tube, inserting position visible
4. Smooth round tip reduce stimulation to tracheal mucosa
5. E.O. gas sterilization, single use only
6. Hard blister packing avoid damage during transportation
7. 5 years shelf time, fresh lot number and manufacturing date
8. ISO, CE certificate
Size Specification:
Size | Tube I.D (mm) | Tube O.D(mm) |
4.0 | 4.0 | 5.5 |
4.5 | 4.5 | 6.2 |
5 | 5 | 6.9 |
5.5 | 5.5 | 7.5 |
6 | 6 | 8.2 |
6.5 | 6.5 | 8.7 |
7 | 7 | 9.3 |
7.5 | 7.5 | 10 |
8 | 8 | 10.7 |
8.5 | 8.5 | 11.3 |
9 | 9 | 12 |
9.5 | 9.5 | 12.7 |
10 | 10 | 13.3 |
How to care for patients after tracheotomy?
The nursing measures after tracheotomy include maintaining
unobstructed cannula, maintaining lower respiratory tract patency,
preventing wound infection, preventing cannula detachment, and
extubation.
1. Keep the cannula unobstructed: After tracheotomy, it is
necessary to keep the cannula unobstructed at all times. If there
is secretion coughing up, it should be immediately wiped off with
gauze. The inner tube should be regularly removed, cleaned,
disinfected, and reinserted in a timely manner to prevent the
secretion from drying and blocking the inner tube. Generally, the
inner sleeve should be cleaned once every 4-6 hours. If there is a
lot of secretions, the cleaning frequency should be increased.
2. Maintain unobstructed lower respiratory tract: Appropriate
temperature and humidity should be maintained indoors, and steam
inhalation therapy should be used or a small amount of
physiological saline, chymotrypsin solution, potassium iodide
solution, or antibiotic solution should be regularly dropped
through a tracheal tube to dilute the sputum and facilitate
coughing up. If necessary, a suction device can be used to suck out
the lower respiratory tract sputum.
3. Prevention of wound infection: Due to sputum contamination,
postoperative wounds are prone to infection, and dressing should be
changed once a day to disinfect the skin around the incision. If
necessary, antibiotics can be used as appropriate to control
infection.
4. Preventing sleeve detachment: If the sleeve is too short or the
strap securing the sleeve is too loose, it can cause the outer tube
to detach. It is important to regularly check whether the sleeve is
inside the trachea. If the casing is found to be dislodged, it
should be immediately reinserted to avoid suffocation. It is not
advisable to replace the external tube within one week after
surgery to avoid accidents caused by difficulty in intubation due
to the absence of a sinus in the anterior tracheal tissue. If
replacement is necessary, instruments such as hooks and vascular
forceps should be prepared.
5. Extubation: If the symptoms of throat obstruction and lower
respiratory tract secretion obstruction have been eliminated,
extubation can be considered. Before extubation, the tube should be
continuously blocked for 24-48 hours. If the patient breathes
steadily during activity and sleep, the cannula can be removed, and
the wound does not need to be sutured. Use butterfly shaped tape to
close the wound edge, and it can heal on its own after a few days.
Close observation should be conducted within 1-2 days after
extubation, and any breathing difficulties should be promptly
addressed.
Product photo:
FAQ:
Q1. Can I have a sample order?
A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.
Q2. What about the lead time?
A: Sample needs 3-5 days, mass production time needs 2-4 weeks for order quantity more than10,000 pcs
Q3. Do you have any MOQ limit for this item?
A: Low MOQ, 1pc for sample checking is available
Q4. How do you ship the goods and how long does it take to arrive?
A: We usually ship by DHL, UPS, FedEx or TNT. It usually takes 3-5 days to arrive. Airline and sea shipping also optional.
Q5. How to proceed an order for medical consumables?
A: Firstly let us know your requirements or application.
Secondly We quote according to your requirements or our suggestions.
Thirdly customer confirms the samples and places deposit for formal order.
Fourthly We arrange the production.
Q6. Is it OK to print my logo on package?
A: Yes. Please inform us formally before our production and confirm the design firstly based on our sample.