Results fordbm64s ultrasound equipment repairfrom 12750 Products.
|
GE B650 Patient Monitor In Stocks For Selling And Repairing Services with good condition Detailed introduction: To repair B Ultrasound PCB, front end, after end, power supply and ...
|
|
|
|
Repair GE BEP power for Logiq E9 (P/N:5393800-3,5166790-2) 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Part number: 5393800-3/ 5166790-2 4. Compatiable with GE Logiq E9 ...
|
|
|
|
GE RIC5-9A-RS 4D Probe Motor Repair Motor Control Failures Motor control failures If the array stops moving or gets stuck, the motor control function has failed and may need to be ...
|
|
|
|
Repair Philips IU22 IE33 453561210241/453561210243 AIM board Spare Parts 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Part Number: 453561210241/453561210243 4. Compatible for ...
|
|
|
|
Fix CX50 Control Board(P/N: 453561685791) 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Part number: 453561685791 4. Compatiable with CX50 Various GE//Siemens/Toshiba/Hitachi/ ...
|
|
|
|
Repair Troubleshoot GE LOGIQ P6 APS II PST DC POWER SUPPLY (P/N:5244555) 1. Part number: 5245004/5244555 2. Compatible with GE Logiq P6 3. With 60 days warranty after fixed 4. ...
|
|
|
|
Samsung L3-12A Ultrasound Transducer Probe Strain Relief Maintenance Model: Samsung L3-12A Fault Phenomenon: can not be tested on the machine, the lens is damaged, the strain ...
|
|
|
|
Samsung E3-12A Ultrasound Transducer Probe Crystal Replacement Probe Repair Model: Samsung E3-12A Fault Phenomenon: There are shadows in the echo, the crystal is broken, but there ...
|
|
|
|
Samsung 3DC2-6 Ultrasound Transducer Probe Dome Replacement Probe Repair Model: Samsung 3DC2-6 Fault Phenomenon: The dome is damaged, and there are 9 piece of crystal are damaged. ...
|
|
|
|
GE RIC6-12-D Ultrasound Transducer Probe 4D Maintenance Model: GE RIC6-12-D Fault Phenomenon: 1. The cable is aging and hard. 2. The whole probe is aging. 3. 4D does not work. 4. ...
|
|
|
|
GE 4C-RS Convex Probe Ultrasound Transducer Lens Replacement Model: GE 4C-RS Fault Phenomenon: The cable is deformed, the image on the machine has dark shadow, and the lens is ...
|
|
|
|
4D Probe Maintenance GE RAB4-8-D Ultrasound Transducer Dome Replacement Model: GE RAB4-8-D Fault Phenomenon: The Dome is damaged and leaking oil, no other abnormalities Suggestion: ...
|
|
|
|
Biosound Biosound SP2430 Phased Array Ultrasound Transducer Probe Replace Lens and Crystal Model: Biosound SP2430 Fault description: The lens is broken, capacitor is in normal ...
|
|
|
|
Biosound Biosound SL1543 Linear Array Ultrasound Transducer Probe Replace Lens and Crystal Model: Biosound SL1543 Fault description: The lens is damaged, the crystal is broken, ...
|
|
|
|
Probe Maintenance for GE 8C-RS Ultrasound Transducer Lens Replacement Model: GE 8C-RS Fault Phenomenon: The cable and strain relief are aging, the image on the computer has dark ...
|
|
|
|
Probe Maintenance for GE C1-6-D Ultrasound Transducer Strain Relief and Connector Cable Replacement Model: GE C1-6-D Fault Phenomenon: The probe has been repaired before, the cable ...
|
|
|
|
Probe Maintenance for GE L6-12-RS Ultrasound Transducer Replace Acoustic Lens Model: GE L6-12-RS Fault Phenomenon: The lens is blistered, and the images on the machine have dark ...
|
|
|
|
Wisonic L15-4 Ultrasound Transducer Probe Replace Acoustic Lens 1. Type: 2D Linear 2. With 60 days warranty after fixed and 3-5 working days to repair Common Probe failure 1. Lens: ...
|
|
|
|
GE C2-5-RS Ultrasound Transducer Crystal Array and Connector Housing Replacement Model: GE C2-5-RS Fault Phenomenon: Lens foaming. 31 pieces of crystal array is damaged. Maintenanc...
|
|
|
|
GE E8C-RS Micro Convex Endocavity 11mm Ultrasound Transducer/Probe 1. Type:convex 2. Frequency: 4-10mhz 3. Compatible system: Portable Voluson, Logiq, and Vivid series 4. ...
|
|
|