Home Companies Shanghai Zhoubo welding & cutting technology CO.,LTD.

Plasma Nozzle 120934 , Plasma Cutting Machine Parts

Shanghai Zhoubo welding & cutting technology CO.,LTD.

Contact Us

[China] country

Trade Verify

Contact name:

Inquir Now

Shanghai Zhoubo welding & cutting technology CO.,LTD.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Plasma Nozzle 120934 , Plasma Cutting Machine Parts

Country/Region china
Categories Seals
InquireNow

Product Details

Plasma Nozzle 120934, Plasma Cutter Machine, Plasma Accessories
 
Shanghai ZhouBo Welding & Cutting Technology company can supply various models of plasma Consumables electrode, nozzle, shield, swirl ring, inner cap, retaining cap, water tube, torch body, such as HT4400, HPR400XD, HPR260XD, HPR130XD, HPR260, HPR130, HSD130, HD3070, HD4070, HT2000, MAX200, POWERMAX1650, POWERMAX1250, POWERMAX65, POWERMAX85, POWERMAX45, POWERMAX30 and so on. Hyperterhm Plasma Consumables, Hyperterhm plasma cutting accessories, Hyperterhm plasma cutter parts, Hyperterhm plasma cutting consumables, Hyperterhm plasma cutter consumables, Hyperterhm plasma cutting tips, Hyperterhm plasma cutter tips, Hyperterhm plasma cutter tips and electrodes, Hyperterhm plasma cutting electrode, Hyperterhm plasma machine torch, Hyperterhm plasma cutting torch, Hyperterhm plasma torch parts, Hyperterhm Plasma cutter Swirl Ring, Hyperterhm plasma cutter nozzle, Hyperterhm plasma cutting nozzle.
 
 

 

MachineHEC NO.Ref NO.Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HT4400

H04785120785Electrode,Oxygen,100Amp
H04793120793Electrode,Oxygen,200Amp
H04802120802Electrode,Oxygen,300Amp
H04810120810Electrode,Oxygen,400Amp
H04855120855Electrode,Nitrogen,200/400Amp
H74783120783Swirl Ring,Oxygen,100Amp
H74784120784Swirl Ring,Oxygen,100Amp,CCW
H74791120791Swirl Ring,Oxygen,200Amp
H74792120792Swirl Ring,Oxygen,200Amp,CCW
H74913120913Swirl Ring,Oxygen,300Amp
H74914120914Swirl Ring,Oxygen,300Amp,CCW
H74939120939Swirl Ring,Oxygen,400Amp
H74940120940Swirl Ring,Oxygen,400Amp,CCW
H74853120853Swirl Ring,Nitrogen,200/400Amp
H14777120777Nozzle,Oxygen,100Amp
H14778120778Nozzle,Oxygen,100Amp,CCW
H14787120787Nozzle,Oxygen,200Amp
H14788120788Nozzle,Oxygen,200Amp,CCW
H14794120794Nozzle,Oxygen 300/Nitrogen 200Amp
H14795120795Nozzle,Oxygen 300/Nitrogen 200Amp,CCW
H14934120934Nozzle,Oxygen,400Amp
H14935120935Nozzle,Oxygen,400Amp,CCW
H14856120856Nozzle,Nitrogen,400Amp
H14857120857Nozzle,Nitrogen,400Amp,CCW
H44786120786Retaining Cap,100/200/300/400Amp
H44907120907Retaining Cap,100/200/300/400Amp With HIS Tab
H44786120786Retaining Cap,100/200/300/400Amp
H44984120984Retaining Cap,100/200/300/400Amp Under Water
H84651120651Torch Main Body
H94025120025Water cooling tube
H94028044028O-ring

 

 

 

 

 

 

 

 

 

HT 4001

H04285020285Electrode,N2
H04663020663Electrode,Oxygen,260Amp
H04630120630Electrode,Oxygen,340Amp
H74039020039Swirl Ring,N2,120/166/187
H74040020040Swirl Ring,N2
H74623020623Swirl Ring,Oxygen
H74135120135Swirl Ring,Oxygen,340Amp
H14281020281Nozzle,N2
H14282020282Nozzle,N2
H14283020283Nozzle,N2
H14284020284Nozzle,N2
H14086020086Nozzle,Oxygen
H44580020580Retaining Cap,N2
H44579020579Retaining Cap
H44185120185Retaining Cap,Oxygen,50Amp

 

 
 
 
Technical Support:

Safety operation procedure for plasma cutting machine

 

A, the use of the former and the cutting

 

1 should check and confirm the power supply, air source, water leakage, leakage, leakage, grounding or zero safe and reliable.

 

2 car, the workpiece should be in the appropriate location, and should be suitable for the workpiece and the cutting of the positive electrode, cutting the work surface should be provided with the dissolution of slag pit.

 

3 according to the workpiece material, the type and thickness of the selected nozzle diameter, internal shrinkage adjustment cutting power supply, gas flow rate and electrode.

 

4 automatic cutting trolley should be empty by far, and the selected cutting speed.

 

5 operators must wear protective masks, gloves, hats, electric membrane anti-dust masks and soundproof earmuffs. Without a protective mirror, the personnel of the plasma arc is strictly prohibited, and the exposed skin is strictly prohibited to be close to the plasma arc.

 

6 when cutting, the operator should stand on the upper hand. From the lower part of a work bench ventilation, and should reduce the operating table of the open area.

 

. cutting, when no-load voltage is too high, should be check the electrical grounding, the insulation connected zero and the torch hand, should be working table and the ground insulation, or in the electric control system installation no-load open circuit breaker.

 

8 high frequency generator shall be provided with shielding, high frequency arc, high frequency circuit should be cut off immediately.

 

9 the use of thorium and tungsten electrodes shall be in accordance with the provisions of article 12.7.8 of the JGJ33-2001.

Hot Products

Stainless Electrode 220307 For HPR130XD Plasma Stainless Steel Cutting We are a professional ...
400A Cutter Nozzle 220632 For Hypertehrm HPR400XD Plasma Cutting assemables We are a professional ...
Silver Plus Tips 220649-S, Mild Steel Bevel Cutting Electrode For HPR130XD Machine We are specialize...
220666 Silver Electrode, Plasma Machine Torch Parts Shanghai ZhouBo Welding & Cutting Technology is ...
220181 Silver Electrode, Plasma Cutting Consumables For HPR130XD Machine Method for prolonging the ...
HT4400 Swril Ring 120792, Plasma Cutter Swril Ring ,Plasma Machine Swirl Ring FAQ: Q1:Can I get a ...