Home Companies Changsha Xingheda Technology Co., Ltd

HUAWEI EX2 TN81EX2 TN8D000EX2 EX4 for Huawei PTN 1900 PTN1900 PTN 3900 PTN3900

Changsha Xingheda Technology Co., Ltd

Contact Us

[China] country

Trade Verify

Address: 2506 Xidi Building, No. 8 Fenglin Third Road, Yuelu District, Changsha City, Hunan Province

Contact name:Amy Lee

Inquir Now

Changsha Xingheda Technology Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

HUAWEI EX2 TN81EX2 TN8D000EX2 EX4 for Huawei PTN 1900 PTN1900 PTN 3900 PTN3900

Country/Region china
City & Province changsha hunan
InquireNow

Product Details

    HUAWEI EX2 TN81EX2 TN8D000EX2 EX4 for Huawei PTN 1900 PTN1900 PTN 3900 PTN3900

Product Description:

1.TN81EX2 Front Panel and Functions

The TN81EX2 supports two 10G optical interfaces, and uses the LC optical fiber connector. It forwards data packets. For the data packets, the TN81EX2 supports QoS functions such as traffic management, congestion control, and queue scheduling.

2.Appearance

Figure 1 shows the appearance of the front panel of the TN81EX2.

Figure 1 Appearance of the front panel of the TN81EX2

3.Indicators

The following indicators are present on the front panel of the TN81EX2.

STAT indicator, red, green, or orange, which indicates the working status

ACT indicator, green, which indicates the service activation status

PROG indicator, red or green, which indicates the running status of the program

SRV indicator, red, green, or orange, which indicates the service status

L/A1 and L/A2 indicators, green or orange, which indicate the receiving, transmitting, and connection states of the data.

For details on indications of indicators, see Board Indicators.

4.Interfaces

Two XFP interfaces, which slope downwards 35 degrees, are present on the TN81EX2. Table 1 lists the types and usage of the interfaces. For fiber corresponding to the interfaces, see Types of Fiber.

 

Table 1 Types and usage of the interfaces on the TN81EX2

Interface on the Front PanelInterface TypeUsage
IN1 - IN2LCReceive 10GE optical signals.
OUT1 - OUT2LCTransmit 10GE optical signals.

NOTE:

The XFP interface should be used with an optical module.

Two LC interfaces are provided on the left and right sides of the optical module. Each interface uses one fiber, which is used to transmit or receive service signals.

When a two-fiber bidirectional optical module is used, two LC interfaces are provided on the left and right sides of the optical module. Each interface uses one fiber, which is used to transmit or receive service signals.

When a single-fiber bidirectional optical module is used, only one LC interface is provided on the left side of the optical module. This optical interface uses only one fiber, which is used to transmit and receive service signals at the same time.

 

Functions and Features:

Table 2 lists the functions and features of the TN81EX2.

Table 2 Functions and features of the TN81EX2

Function and FeatureDescription
Basic functionService interfaces on the front panelTwo 10GE interfaces.
Processing capabilityFull-duplex 20 Gbit/s
DCNThe inband DCN is supported. By default, the two ports on the board are enabled with the DCN function, and the DCN function can be automatically enabled or disabled.
Interface functionWorking mode10G Full-Duplex LAN, 10G Full-Duplex WAN
Automatic laser shutdownSupported
Type of the loopback at the port

PHY layer inloop and outloop

MAC layer inloop

Automatic loopback release on interfacesSupported
Interface bandwidth usage statisticsSupported
MTU46 bytes to 9000 bytes
Leveled port bandwidth threshold-crossing alarmsSupported
Performance statistics based on different prioritiesSupported

 

1.Working Principle and Signal Flow

The TN81EX2 mainly consists of the network management module, transmission management module, switching buffer module, management module, power supply module, and clock module.

Figure 1 shows the block diagram for the working principle of the TN81EX2.

Figure 1 Block diagram for the working principle of the TN81EX2

2.In the Transmit Direction

The cross-connect buffer module processes the cells sent by the cross-connect unit and then sends the cells to the transmission management module. The transmission management module rearranges the cells to recover packets, for which the buffer and QoS management are performed. The packets are then sent to the network processing module. The network processing module performs the coding/decoding and the serial/parallel conversion for the data, and then sends the data to the 10 GE optical interface.

3.In the Receive Direction

The network processing module performs the O/E conversion for the Ethernet optical signals from the port of the Ethernet equipment, and performs the coding/decoding and the serial/parallel conversion for the data. The network processing module also performs route searching and address matching for the data packets, and transmits the corresponding packets to the transmission management module. After the transmission management module buffers and schedules the packets, the transmission management module slices the packets into cells required by the switching network. After the switching buffer module buffers the cells, the cells are then sent to the cross-connect unit.

4.Network Processing Module

The functions supported by this module are listed as follows:

In the receive direction, performs the O/E conversion for the 10GE Ethernet optical signals from the port of the Ethernet equipment (switch or router), and performs the coding/decoding.In the transmit direction, perform the coding and parallel/serial conversion on the signals from the transmission management module, and then perform the O/E conversion and transmit the signals.

5.Performs route searching and address matching for the data packet.

Extracts the synchronous Ethernet clock signals.

Extracts the IEEE 1588 V2 packets.

Transmission Management Module

This module slices packets into cells, and performs the QoS, line rate forwarding, and large volume buffer functions. The functions supported by this module are listed as follows:

QoS: This module provides functions of scheduling services and restricting the bandwidth, which include the flow queues and port queues. In addition, this module provides the statistics information accordingly.

Line rate forwarding: This module can bi-directionally transmit and receive packets at the full line rate, that is, 20 Gbit/s.

Large volume buffer: This module supports 50-ms buffer in the case of 20 Gbit/s traffic.

6.Switching Buffer Module

This module mainly performs buffer, queue management, and scheduling for cells. This module and the cross-connect unit form a three-level switching fabric to switch cells.

Management Module

This module provides buses, such as the parallel management bus and Ethernet communication bus, to manage other modules on the board. This module also monitors and reports alarms and performance events to the system control unit.

7.Clock Module

The functions supported by this module are listed as follows:

Provides clock signals for each module of the board.

Supports the synchronous Ethernet.

Supports the IEEE 1588 V2 protocol.

Supports the 1588 ACR clock.

8.Power Supply Module

This module converts the input DC voltage into various DC voltages required by each module on the board.

Valid Slots

Two slots house one TN81EX2. On the U2000, the two slots are displayed as the one with the smaller number. For example, slots 3 and 4 house the TN81EX2. On the U2000, only slot 3 is displayed.

 

Table 1 lists the valid slots for the TN81EX2.

Table 1 Valid slots for the TN81EX2

Slots for the TN81EX2Remarks
Slots 5Slot 5 actually represents slot 5 and slot 6. The board housed in these two slots provides interfaces on the front panel.
Slots 7Slot 7 actually represents slot 7 and slot 8. The board housed in these two slots provides interfaces on the front panel.
Slots 11Slot 11 actually represents slot 11 and slot 12. The board housed in these two slots provides interfaces on the front panel.
Sots 13Slot 13 actually represents slot 13 and slot 14. The board housed in these two slots provides interfaces on the front panel.

 

Product Detail:

If you are interested, please let us know the specific model. We will provide the best service and the best price!




 

 

Pr

Hot Products

HUAWEI WBBPb3 QWL1WBBPB3 020KWP Processing Unit for Huawei WCDMA UMTS BBU3900 ​ Technical specificat...
HUAWEI 2102311BBM RRU3959 1800MHZ M for huawei rru 3959 equipment ​ Product Description: HUAWEI GSM...
HUAWEI 2102317139 RRU3606 Base Station RRU3606 DBS3900 CDMA 800M ​ Product Description: Product Name ...
HUAWEI EMUB Monitoring Unit HUAWEI WD2G1EMUB -48VDC 32 positions ​ Product Description: Functions of ...
HUAWEI EX2 TN81EX2 TN8D000EX2 EX4 for Huawei PTN 1900 PTN1900 PTN 3900 PTN3900 ​ Product Description...
HUAWEI RRU3936 02310MNQ 1800MHZ for huawei DBS3900 Series units ​ Product Description: Item ...