Grouting flow recording equipment, grouting automatic recorder
Grouting recorder is an automated monitoring system used in water
conservancy and hydropower grouting construction. Its function is
to collect grouting process parameters such as grouting pressure,
flow rate, density, and lifting through the grouting automatic
recorder during the grouting process, and display these collected
parameters on the grouting automatic recorder. Because grouting
engineering is an underground concealed project, the application of
instruments is mainly to improve the efficiency of grouting
engineering work, reduce the factors of inaccurate and false human
records, and thus help ensure the quality of grouting engineering.
Instrument model: JT-E6 (English version)
Product Introduction
The grouting recorder integrates microcomputer technology
processing, a seven inch true color touch screen, parameter
display, setting, and printing functions. It can record the flow
rate, pressure, density, and time during the grouting process
without the need for buttons or a mouse, making it simple and
intuitive. Parallel port printers can be used on-site for printing,
and data export and archiving with USB drives are also supported.
The grouting automatic recorder is available in two models: one
trailer and one trailer. Suitable for curtain grouting, karst
grouting, compaction grouting, double liquid grouting,
consolidation grouting, backfill grouting, joint grouting, anchor
grouting, high-pressure rotary jet grouting, multi head
small-diameter deep mixing piles, highway maintenance grouting and
other series of grouting processes.
performance parameter
1. Power supply voltage: AC220V ± 10%
2. Suitable temperature: -40~60 ℃
3. Working humidity: ≤ 90%
4. Host accuracy: 0.05%
5. LCD screen: seven inch true color touch screen
6. Channel configuration: One to Two
7. Host size: 42.5cm * 30.5cm * 15.5cm
8. Host weight: 8.4Kg
9. Standard flow rate: range 0-150 L/min, resolution 0.01L/min
(accuracy 0.5%, can be customized according to customer
requirements)
10. Standard pressure: range 0-10 MPa, resolution 0.01 MPa,
accuracy 0.5% (can be customized according to customer
requirements)
11. Standard density: range 0-2.5 g/cm3, resolution 0.01g/cm3,
accuracy 0.5% (can be customized according to customer
requirements)
Product Features
1. Widely used in various grouting processes such as curtain
grouting, karst grouting, consolidation grouting, high-pressure
rotary jet grouting, GIN grouting, prestressed grouting, and simple
water pressure, conventional water pressure, five point water
pressure, punching, etc;
2. Adopting an integrated design, the key components of the
instrument are made of imported electronic components, which can
effectively prevent moisture, dust, shock, and electromagnetic
interference. It is equipped with a built-in stabilized power
supply and suitable for construction sites with scattered workfaces
and harsh environments, such as tunnels, subway entrances, etc;
3. Supports 1 channel and 2 channels, with options for two
parameter small loop, two parameter large loop, three parameter
small loop, and three parameter large loop. The software
automatically recognizes them without the need to change settings;
4. The interface adopts a 7-inch LCD screen display, full English
prompts, and can query historical grouting records;
5. Real time display of all grouting parameters for two grouting
channels on the same screen;
6. Data automatic power-off protection, work can be restored upon
incoming call.
Installation diagram of grouting automatic recorder:
Troubleshooting of grouting automatic recorder:
Common fault cause analysis table | ||
Fault phenomenon | Possible causes | Removal method |
The actual flow rate of the electromagnetic flow meter is shown to be zero | 1,The actual flow direction of the fluid is opposite to the direction indicated by the sensor | Change direction of sensor installation |
2,Electrode signal to ground short circuit | Damage or break of signal cable insulation | |
3,No excitation current | The excitation cable is broken or damaged | |
4,The electrode is completely covered by insulation | Clean the electrode and remove the covering | |
The actual flow of the electromagnetic flow meter is stable and the indication value is unstable | 1,The measured fluid is not filled with a measuring tube | Change the position and manner of sensor installation so that the fluid is filled with the measuring tube |
2,The fluid under test contains more bubbles or oil | Remove bubbles or oils | |
3,Sensor ground fault | Sensor grounding | |
4,The electrode is heavily covered by insulation | Cleaning electrode | |
5,The power supply is unstable and the interference is large | Separate power supply or anti interference stabilized power supply | |
6,There is a strong interference device nearby | Change installation location to avoid interference sources | |
The pressure transmitter and the density sensor are not displayed or unstable | 1,Is the input voltage switched on? | Reconnect voltage |
2,Input voltage positive and negative connection | Changing voltage plus or Minus Voltage | |
3,Sensor bad | Replace sensor | |
The pressure transmitter and the density sensor display very large and do not change | 1, Sensor bad | Replace sensor |
The pressure transmitter and the density sensor display unstable or almost zero | 1, Is the sensor joint sealed? | Re seal |