Home Companies Shenzhen Coolmay Technology Co., Ltd.

7 Inch HMI PLC Allinone QM3G-70FH Programmable Logic Controller With Touch Screen

Shenzhen Coolmay Technology Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: #526, Block E, Building 5, Software Industry Base, Nanshan District, Shenzhen , China, 518061

Contact name:Sandra

Inquir Now

Shenzhen Coolmay Technology Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

7 Inch HMI PLC Allinone QM3G-70FH Programmable Logic Controller With Touch Screen

Country/Region china
City & Province shenzhen
Categories Electronic Products & Components Processing
InquireNow

Product Details

7 Inch HMI PLC Allinone QM3G-70FH Programmable Logic Controller With Touch Screen
 
In the field of personalized applications, coolmay technology provides users with a PLC application platform to create high-performance industrial integration control solutions for users, saving time and cost for users, improving efficiency and enhancing corporate competitiveness.
 
PRODUCT DESCRIPTION of HMI PLC ALL IN ONE

Feature:

1. Support several high-speed counting and high-speed pulse.Acceleration and deceleration are independent.The total high-speed counting and pulse can not exceed 480KHz
2. 32K steps program capacity.32K power-off retentive registers.support interrupt.linear and circular interpolation.PID self-adjusting
3. Special encrvotion.Set password as 12345678 to thorouahly prevent readina dataPLC only supporls 8-bit password encryotion
4. PLC is compatible with programming software GX Developer8.86Q and GX Works2and HMl is mView software.
5. The network module can be selected accordina to customer reauirements to realize remote control More models are supported to customize if bulk order.

  1.  

  2. ModelQM3G-70FH
    Dimension200*146*36mm
    Cutout size192*138mm
    Input24VDC
    Power Consumption6-7W
    HMI
    Feature60K colors resistive touch screen, supports portrait display
    Type7.0"TFT
    Display size154*87mm
    Resolution(pixels)800*480
    RAM64MB (Please inquire if requires storing historical data)
    ROMNOR Flash 16MB
    CPU32bit CPU 408MHz
    COM portsType-C HMI download port (can download PLC program through the USB penetrating function), RS232 port
    SoftwareCoolmay TPWorks HMI Programming Software
    PLC
    I/O level

    - Input: Passive NPN, public terminal isolated

    - Transistor output: Low level NPN, COM connect to negative

    - Relay output: Normally open dry contact

    DO type and load

    - MT: 2A/point, 4A/4 points COM; MT: 0.5A/point, 0.8A/4 points COM, 1.6A/8 points COM

    - MR: 2A/point, 4A/4 points COM, 5A/12 points COM.

    High-speed countingSingle phase 6 channel 60KHz, or 2 AB 60KHz + 1 AB 10KHz, or 2 ABZ 60KHz + 1 AB phase 10KHz

    High-speed pulse

    (Only for MT models)

    8 channels, Y0-Y3 is 100KHz, Y4-Y7 is 10KHz.

    High-speed counting + high-speed pulse < 480KHz

    COM port1x TYPE-C, 1x RS232, 1x RS485
    SoftwareCompatible with GX Developer8.86 and GX WORKS 2
    Detailed info. refer to: “Coolmay QM3G-FH All-in-One User Manual”, “Coolmay CX3G/FX3GC PLC Programming Manual”, “Coolmay TP HMI User Manual
     
    Packaging & Shipping

    Packaging

    The products will be under testing for 1-3 days and packed with carton box .

 

 

FAQ

1.Precautions of using PLC transistor and relay
The PLC output is a common cathode output, the theoretical value is 1A, the actual use is less than 500mA, the COM wiring is negative, please use 24V voltage, there is no voltage output when it is used as a switch. If an external relay, the relay needs an external power supply.
The relay has a contact life, the theoretical value is 30W times, and the theoretical value of the external load does not exceed 5A. Frequently, the full load current may affect the service life, and there is no voltage out.
2.Precautions of Coolmay PLC output type selection
MT: indicates the transistor output, MR: indicates the relay output, and MRT: indicates the relay transistor mixed output.
The main differences between transistor output and relay output are:
(1)The difference in current load. At present, we use a transistor with a maximum current load of 500MA, and the maximum current load of the relay is 5A (the maximum relay current of the EX2N(S)/DX2N(S) series PLC is 3A);
(2)Output power: The transistor can only be connected to the DC24V power supply , and the relay can be connected to the DC24V and AC220V power supply ;
(3)Functional characteristics: If you need to send a pulse to drive a stepper motor, you should use the transistor output or the mixed output. Also if the output switch is active, it is recommended to use a transistor output;
(4)If both the relay and the transistor are available, it is recommended to use a transistor output because the transistor has no contact life limit and the lifetime will be longer than the relay as long as the current does not exceed the limit.

 

 
  1.  

Hot Products

Industrial Control PLC 16DI/16DO Relay Modular And Expandable PLC Built In Ethernet Port Quick ...
7 Inch HMI PLC Allinone QM3G-70FH Programmable Logic Controller With Touch Screen In the field of ...
10 Inch HMI PLC Temperature and humidity controller QM3G-100FH The all-in-one solution is to ...
PLC Programmable Logic Controller 24DI Input 24DO Output PLC controller*1 PLC programming cable*1 ...
Servo PLC All In One DC24V 16DI 16DO Built In Programmable Logic Controller (PLC) MX3G-C40/C75 servo ...
Integrated HMI PLC 12DI 12DO Works 2 Programming Software With 6 High-Speed Counts And 8 High-Speed ...