DC24V HMI Operator Panel 65536 True Colors RS232 RS485 Support MODBUS Free Port

Country/Region china
City & Province shenzhen
InquireNow

Product Details

DC24V Hmi Operator Panel 65536 True Colors RS232 RS485 Support MODBUS Free Port

 

Human-Machine Interface (HMI) connects industrial control equipment such as programmable logic controllers (PLC), frequency converters, DC speed regulators, and meters. It is a digital device that uses the display screen to write working parameters or input operating commands through an input unit (such as a touchpad, a mouse, etc.) to realize information interaction between humans and machines. It consists of two parts: hardware and software.

 

PRODUCT DESCRIPTION 

USB port: Yes

Calendar: Yes

lnput voltage: DC24土10%VDC or customized as DC12V/DC5V input

System diagnosis: Power effect test

Certificate: CE

FCC: Conform to FCC Class A

Anti-interference test : 1500Vp-p, pulse period 1us,continue 1s

Quakeproof test: 10-25Hz(X,Y,Z direction 2G 30mins)

Insulation resistance: More than 10MQ@500VDc

Touch panel: 4-wire resistance panel

Features:

High precision/reliability resistive touch panel

Support various formats of static images and GIF animations

Support all fonts provided by Windows.

6000 TFT true color display

Equipped with an SD card that can store historical data

Can display vertically

Comes with an RS232 and RS485 communication port, supporting multiple protocols

ModelMT6070i
SpecsDimension212*146*36mm
 Cutout size192*138mm
 Display size154*87mm
 Weight(kg)0.54
DisplayDisplay7” TFT
 

Resolution

(pixels)

800*480
 Brightness300cd/m² 
 Contrast ratio400:1
 BacklightLED
 Backlight time60,000 h
 Display color65536 true colors
 Touch type4-wire resistive panel
StorageROMNOR Flash 16MB(Disk C of system area)+SD NAND 128MB(Disk D)
 RAM64MB
 CPU32bit CPU 408MHz
InterfaceSD cardBuilt in SD card (used to store historical data)
 USB portUSB 2.0×1 (USB port , can be used to update programs and upload and download historical data; it can not be used with Type-C/Type-B download interface at the same time)
 Download portTYPE-C
 Ethernet portOptional
 COM port1 RS232 and 1 RS485
 ProtocolSupport MODBUS, free port and common PLC communication Protocol
AudioOptional
CalendarYes
Input VoltageDefault as DC12~24±10%V
Consumption200mA*24V
Protection ClassIP65 (front panel)
TemperatureAmbient environment: 0~50℃ | Storage environment: -20~70℃
Humidity20%~90% RH
CertificationCE
Software

CoolMay HMI programming software

Detailed info. refer to CoolMay HMI user manual, CoolMay HMI programming manual

 

Service advantages

Production equipment

Coolmay, which has 15 years of expertise in automation solutions for various industries, has6000 square meters of production space and 10 production lines, many imported high-end smtplacement equipment and testing equipment, and its monthly output can reach 50,000 units.

Raw materials and accessories

The raw materials and parts used by Coolmay are the best: the CPU adopts imported 32-bitindustrial-grade chips, the PCB board with three anti-paint protection, the relays and transistorsimported from the United States, and the input and output with photoelectric isolation protection.

FAQ

1.Precautions of using PLC transistor and relay
The PLC output is a common cathode output, the theoretical value is 1A, the actual use is less than 500mA, the COM wiring is negative, please use 24V voltage, there is no voltage output when it is used as a switch. If an external relay, the relay needs an external power supply.
The relay has a contact life, the theoretical value is 30W times, and the theoretical value of the external load does not exceed 5A. Frequently, the full load current may affect the service life, and there is no voltage out.
2.Precautions of Coolmay PLC output type selection
MT: indicates the transistor output, MR: indicates the relay output, and MRT: indicates the relay transistor mixed output.
The main differences between transistor output and relay output are:
(1)The difference in current load. At present, we use a transistor with a maximum current load of 500MA, and the maximum current load of the relay is 5A (the maximum relay current of the EX2N(S)/DX2N(S) series PLC is 3A);
(2)Output power: The transistor can only be connected to the DC24V power supply , and the relay can be connected to the DC24V and AC220V power supply ;
(3)Functional characteristics: If you need to send a pulse to drive a stepper motor, you should use the transistor output or the mixed output. Also if the output switch is active, it is recommended to use a transistor output;
(4)If both the relay and the transistor are available, it is recommended to use a transistor output because the transistor has no contact life limit and the lifetime will be longer than the relay as long as the current does not exceed the limit.

 

Hot Products

LED Industrial Hmi Panels 480*272 Pixels 300cd/M² SD Card IP65 Optional Audio Human-Machine ...
Led 146*88*25mm 5 inch hmi display 32bit CPU 408MHz DC12~24±10%V 64MB MODBUS Human-Machine Interface ...
DC24V Hmi Operator Panel 65536 True Colors RS232 RS485 Support MODBUS Free Port Human-Machine ...
Coolmay 10 Inch Him Human Interface Machine Built In SD Card Type-B 280mA*24V DC12~24±10%V Human...
Product Description: The HMI Control Panel is a human machine interface (HMI) device designed to ...
Product Description: The CoolMay HMI Control Panel is a highly customizable product that provides ...