Home Companies Ningbo Suntech Power Machinery Tools Co.,Ltd.

Long HV XLPE Cable Testing Device / Hv Test Equipment 3000KVA Or OEM Capacity

Ningbo Suntech Power Machinery Tools Co.,Ltd.

Contact Us

[China] country

Trade Verify

Address: NO.61 Xiachen'an Road,Xiwu Street,Fenghua District,Ningbo,China.315505

Contact name:Peter

Inquir Now

Ningbo Suntech Power Machinery Tools Co.,Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Long HV XLPE Cable Testing Device / Hv Test Equipment 3000KVA Or OEM Capacity

Country/Region china
City & Province ningbo zhejiang
Categories Tool Cases & Bags
InquireNow

Product Details

Variable Frequency Resonant Withstand Voltage Test Reactor For Long HV XLPE Cable

 

I. Application :


The high voltage test reactor is HV booster or generator in the variable frequency resonant withstand voltage circuit, it has large capacity and HV for one piece with higher Quality factor putput . it is special for the high voltage XLPE cable test with longer distance .

 

Fanke company can finish the design and produce the goods according to all kinds of customer's requirement . such as cylinder type and iron tank type .

 

Test reactor can be produced to be 130KV,150KV,155KV,200KV, 250KV, 300KV, 350KV, 400KV for each piece rated voltage according to different tested object scope or customer requried. The max. rated current of each HV reactor can be 1~5A,10A,15A,20A,25A,30A.

 

II. Test priciple figure:
Portable Variable Frequency Resonant Withstand Voltage Test Set

VF: Variable Frequency Power Supply Source which is control and measurement part in the test circuit.

T : Excitation Transformer which provide the exciting voltage for HV test reactor
L : Test Reactor which is resonant inductance in the LC circuit and produce the test voltage

Cx: Tested Equipment

MOA1: Lightning Arrestor is protection part on the excitation transformer
C1,C2: Voltage divider(C1 is high voltage arm,C2 is low voltage arm ) which is HV voltage measurement part


III. General Technical data:

  1. Mode of system test: Series resonant with variable frequency
  2. System model : OEM
  3. Input power supply : 380±10%(three-phase),50Hz/60Hz
  4. Number of HV test reactor: OEM
  5. Rated output capacity: OEM
  6. Rated output Voltage: 150KV or OEM
  7. Max Test voltage : no more than 150KV,300KV,450KV
  8. Rated output current: 25A max or OEM
  9. Reg. Freq range : 20Hz-300Hz
  10. Output Resonance voltage waveform: sine wave
  11. THD of output waveform: ≤1%
  12. Insulation level: Under 1.1 times and keeping 1min, normal
  13. Duty cycle : 60mins on under rated current working condition ;
  14. Quality factor of test set itself: Q≥60
  15. Temperature rise: Less than 65K under rated current working 60mints;
  16. Noise level: No more than 65dB
  17. Reactor Structure: oil immersed type, epoxy tube cylinder type;

 

IV.Accessories

  • Necessary corona rings
  • Parallel cables of the reactor
  • HV output cables(reactor to divide)
  • Corona ring for test reactor
  • A final test report, a quality Certificate ,a user manual and a packing list are offered .


V. Typical model of test reactors

 

1 Optional model for 132KV class XLPE cable on-site withstand voltage test

 

ModelRated voltageRated output currentRated output capacityMax Application
CHX-775KVA/155KV155KV5A775KVA132kV cable≤1km
CHX-1550KVA/155KV155KV10A1550KVA132kV cable≤2km
CHX-2325KVA/155KV155KV15A2325KVA132kV cable≤3km
CHX-3100KVA/155KV155KV20A3100KVA132kV cable≤4km
CHX-3875KVA/155KV155KV25A3875KVA132kV cable≤5km
CHX-7750KVA/155KV155KV50A7750KVA132kV cable≤10km
CHX-12400KVA/155KV155KV80A12400KVA132kV cable≤16km
CHX-15500KVA/155KV155KV100A15500KVA132kV cable≤20km
Special requirement can be made by order

Note :Tested cable voltage class≤ 132kV, 0.25uF/km

 

2 Optional model for 230KV class XLPE cable on-site withstand voltage test

 

ModelRated voltageRated output currentRated output capacityMax Application
CHX-2020KVA/255KV255KV8A2020KVA220~230kV cable≤1km
CHX-4080KVA/255KV255KV16A4080KVA220~230kV cable≤2km
CHX-6120KVA/255KV255KV24A6120KVA220~230kV cable≤3km
CHX--8160KVA/255KV255KV32A8160KVA220~230kV cable≤4km
CHX--10200KVA/255KV255KV40A10200KVA220~230kV cable≤5km
CHX--20400KVA/255KV255KV80A20400KVA220~230kV cable≤10km
CHX--25500KVA/255KV255KV100A25500KVA220~275kV cable≤12.5km
Special requirement can be made by order

Note :Tested cable voltage class≤ 230kV, 0.25uF/km

 

3 Optional model for 330KV class XLPE cable on-site withstand voltage test

 

ModelRated voltageRated output currentRated output capacityMax Application
CHX-3500KVA/350KV350KV10A3500KVA330kV cable≤1km
CHX-7000KVA/350KV350KV20A7000KVA330kV cable≤2km
CHX-10500KVA/350KV350KV30A10500KVA330kV cable≤3km
CHX-14000KVA/350KV350KV40A14000KVA330kV cable≤4km
CHX-21000KVA/350KV350KV60A21000KVA330kV cable≤5km
CHX-28000KVA/350KV350KV80A28000KVA330kV cable≤10km
Special requirement can be made by order

Note :Tested cable voltage class≤ 330kV, 0.25uF/km

 

4 Optional other model for long XLPE cable on-site withstand voltage test

 

ModelRated voltageRated output currentRated output capacity

Application

(From 20Hz starting)

CHX-2600KVA/130KV130KV10A,20A1300KVAFor U0=64KV and below cable
CHX-3000KVA/150KV150KV10A, 20A3000KVAFor U0=87KV and below cable
CHX-10000KVA/250KV250KV20A, 40A10000KVAFor U0=127KV and below cable
CHX-20000KVA/250KV250KV20A, 80A20000KVAFor U0=127KV and below cable
CHX-21000KVA/350KV350KV20A, 60A21000KVAFor U0=230KV and below cable
CHX-42000KVA/350KV350KV20A, 80A42000KVAFor U0=230KV and below cable
Special requirement can be made by order

Note : XLPE cable test voltage is considering as 1.7U0

 

5 Optional model for HV or EHV class cable and GIS On-site AC hipot test

 

ModelRated voltageRated output currentRated output capacity

Application

(From 20Hz starting)

CHX-2600KVA/130KV,260KV130KV,260KV20A@130KV2600KVA

For U0=64KV cable

For 72.5KV class GIS

10A@260KV

For U0=127KV cable

For 145KV class GIS

CHX-9000KVA/150KV,300KV150KV,300KV60A@150KV9000KVA

For U0=87KV cable

For 72.5KV class GIS

30A@300KV

For U0=160KV cable

For 170KV class GIS

CHX-10000KVA/250KV,500KV250KV,500KV40A@250KV10000KVA

For U0=127KV cable

For 145KV class GIS

20A@500KV

For U0=290KV cable

For 362KV class GIS

CHX-20000KVA/250KV,500KV250KV,500KV80A@250KV20000KVA

For U0=127KV cable

For 145KV class GIS

40A@500KV

For U0=290KV cable

For 362KV class GIS

CHX-21000KVA/350KV,700KV350KV,700KV60A@350KV21000KVA

For U0=190KV cable

For 170KV class GIS

30A@700KV

For U0=290KV cable

For 550KV class GIS

Special requirement can be made by order

 

 

VI. On-site test standard table from IEC 60840:2011 and IEC 62067:2011 for XLPE cable

 

Long HV XLPE Cable Testing Device / Hv Test Equipment 3000KVA Or OEM Capacity 1

 

Long HV XLPE Cable Testing Device / Hv Test Equipment 3000KVA Or OEM Capacity 2

VII. On-site insulation test standard table from IEC 62271-203:2011 for HV GIS

 

Long HV XLPE Cable Testing Device / Hv Test Equipment 3000KVA Or OEM Capacity 3

Hot Products

PD Free AC Withstand Voltage Test Systems With Cylinder Type Transformer , Partial Discharge ...
Full-automatic Transformer Integrated Test Bench , Power Transformer Comprehensive Test Systems I. ...
SKDP Model 10KN Parallel Earth Wire Gripper Come Along Clamp Basic Construction Tools Suntech Power ...
Variable Frequency Resonant Withstand Voltage Test Set , High Voltage Test Set For UHV Substation or ...
Power Frequency AC Resonant Withstand Voltage Test Set , Power Frequency Resonant Intelligent ...
Power Frequency AC Resonant Withstand Voltage Test Set , For EHV CVT and CB Rutine Testing I. ...