High Precision Barbiturates( BAR) Drug Abuse Diagnosis 300ng/ml Test Powder Panel Kit With CE

 

PrincipleChromatographic Immunoassay
FormatDipstick, Cassette, Panel, Device, Cup
SpecimenUrine,Oral Fluid,Powder,WB/S/P,Hair
CertificateCE/FDA
Reading Time5 minutes
Pack10T/25T/40T/50T
Storage Temperature2-30°C
Shelf Life2 Years
Sensitivity96.10%
Specificity98.60%
Accuracy97.60%
Cut-Off100 ng/mL,200 ng/mL,

 

Application:

 

The barbiturates Rapid Test Panel is a rapid chromatographic immunoassay for the qualitative detection of barbiturates a cut-off 300ng/ml.


This assay provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result.

 

Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are indicated.

 

Description:

 

Barbiturates are CNS depressants. They are used therapeutically as sedatives, hypnotics, and anticonvulsants barbiturates are almost always taken orally as capsules or tablets. The effects resemble those of intoxication with alcohol. Chronic use of barbiturates leads to tolerance and physical dependence.
 
Short-acting barbiturates taken at 400 mg/day for 2-3 months can produce a clinically significant degree of physical dependence. Withdrawal symptoms experienced during periods of drug abstinence can be severe enough to cause death.The barbiturates assay contained within the BAR Rapid Test Panel yields a positive result when the BAR concentration exceeds 300ng/ml.

 

How to use?

 

Test device (in closed pouches), samples, and controls should be brought to room temperature (15-30°C) prior to testing. Do not open pouches until ready to perform the assay.


Remove the test device from its protective pouch and label the device with patient’s identification or control label.
FOR SURFACES


1.Wipe with the panel over the surface in which the drugs are expected.
2. Take off the cap of supplied tube;
3. Fill all buffers from the supplied tube of buffer into the protection cover.
4. Insert the Multi Test slowly and carefully into the protection cover with buffer
5. Wait for lines to appear on the membrane and read the results after 5 minutes and do not interpret the result after 10 minutes.


 

FOR SOLIDS
1. Open the tube and put the solid in to the buffer.
2. Close the tube with dropper and cap. Shake it a short time. Wait for 30 sec.
3. Take off the cap of supplied tube;
4. Fill all buffers with dissolved substances into the protection cover.
5. Insert the Multi Test slowly and carefully into the protection cover with buffer.
6. Wait for lines to appear on the membrane and read the results after 5 minutes and do not interpret the result after 10 minutes.

 

 

INTERPRETATION OF RESULTS
(Please refer to the illustration above)

NEGATIVE:* A colored line appears in the Control region (C) and colored lines appear in the Test region (T). This negative result means that the concentrations in the sample are below the designated cut-off levels for a particular drug tested.


*NOTE: The shade of the colored lines(s) in the Test region (T) may vary. The result should be considered negative whenever there is even a faint line.

POSITIVE: A colored line appears in the Control region (C) and NO line appears in the Test region (T). The positive result means that the drug concentration in the sample is greater than the designated cut-off for a specific drug.


 

INVALID: No line appears in the Control region (C). Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for Control line failure. Read the directions again and repeat the test with a new test card. If the result is still invalid, contact your manufacturer.

 

Order Information

 

Cat. No.ProductSpecimenPack
DBA-102Barbiturate (BAR) Rapid Test CassetteUrine40T
DBA-114Barbiturate (BAR) Rapid Test PanelUrine40 T
DBA-101Barbiturate (BAR) Rapid Test DipstickUrine50 T
DBA-802Barbiturates (BAR) Rapid Test CassetteOral Fluid25 T
DBA-803Barbiturates (BAR) Rapid Test DeviceOral Fluid25 T
DBA-402Barbiturates (BAR) Rapid Test CassetteWB/S/P40 T
DBA-X14Barbiturate (BAR) Rapid Test PanelPowder25 T
DBA-H902Barbiturate (BAR) Rapid Test CassetteHair10 T

Hot Products

100 ng/mL Panel/Cassette/Dipstick Accurate Alprazolam Single Drug Rapid Urine Test Medical Product ...
Stable Amphetamine (AMP)Single Drug Rapid Urine Test Panel/Cassette/Dipstick Medical Product ...
High Precision Barbiturates( BAR) Drug Abuse Diagnosis 300ng/ml Test Powder Panel Kit With CE ...
Medical Diagnosis Prostate specific antigen (PSA) Qualitative Rapid Test Kits For Prostate Cancer ...
Carcinoembryonic Antigen (CEA) Rapid Test Cassette One Step Disposable For Diagnosis Product ...
Fast reading High Sensitive Accurate One Step CA-125 Rapid Test Cassette Disposable for Diagnosis ...