Home Companies CITEST DIAGNOSTICS INC.

Micro Albumin Rapid Test Dipstick Qualitative Detection Microalbuminuria

CITEST DIAGNOSTICS INC.

Contact Us

Trade Verify

Address: 170-422, Richards Street, Vancouver BC V6B 2Z4, CANADA

Contact name:Rosy

Inquir Now

CITEST DIAGNOSTICS INC.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Micro Albumin Rapid Test Dipstick Qualitative Detection Microalbuminuria

City & Province hangzhou zhejiang
InquireNow

Product Details

Micro - Albumin Rapid Test Dipstick Qualitative Detection Microalbuminuria

 

Product featuresParameters
PrincipleChromatographic Immunoassay
FormatDipstick, Cassette
SpecimenUrine
CertificateCE
Reading Time5 minutes
Pack25 T/50 T
Storage Temperature2-30°C
Shelf Life2 Years
Sensitivity97.80%
Specificity83.30%
Accuracy92.00%
Cut-Off20-40-60-80 ug/mL

 

A rapid test for the qualitative detection of Micro-Albumin CE certified

 

Applications: 

 

The Micro-Albumin Rapid Test Dipstick (Urine) is a rapid chromatographic immunoassay for the qualitative detection of micro-albumin in human urine.

 

Description: 

 

The persistent appearance of small amounts of albumin in urine (microalbuminuria) may be the first indicator of a renal dysfunction. For diabetic patients, positive results may be the first indicator of a diabetic nephropathy. Without therapy, the amount of released albumin will increase (macroalbuminuria) and renal insufficiency will occur. In cases of Type 2 diabetes, the early diagnosis and therapy of diabetic nephropathy is especially important. 

 

In addition to being the earliest manifestation of nephropathy, albuminuria is also a marker of an increased risk for cardiovascular diseases in type-2 diabetes. In normal physiological conditions, small amounts of albumin are glomerularly filtrated and tubularly reabsorbed. The expulsion of 20 μg/mL to 200 μg/mL albumin in urine is characterized as microalbuminuria. In addition to renal dysfunction, a transient   albuminuria might also be caused by physical training, infection of the urinary tract, hypertension, cardiac insufficiency and surgery.

 

How to use? 

  1. Remove the test dipstick from the sealed foil pouch and use it as soon as possible. Best results will be obtained if the assay is performed immediately after opening the foil pouch.
  2. Hold the dipstick by the end, where the abbreviation of the analyte is printed. To avoid contamination, do not touch the membrane of the dipstick.
  3. Holding the dipstick vertically, dip the tip of the test dipstick in the urine specimen for at least 10-15 seconds. Do not immerse past the maximum line (MAX) on the test dipstick.As the test begins to work, color will migrate across the membrane. 
  4. After the liquid front has reached the upper end, remove the dipstick from the specimen and place it on a non - absorbent flat surface. Start the timer and wait for the colored line (s) to appear. 
  5. The result should be read at 5 minutes. Do not interpret the result after 10 minutes.

INTERPRETATION OF RESULTS

 

(Please refer to the illustration above)

 

NEGATIVE: Two lines appear. One colored line should be in the control line region (C) and another apparent colored line should be in the test line region (T).This indicates that the albumin concentration of the sample is below the cut-off (20ug/ml) of the assay.

 

POSITIVE: Only one line appears. Only one line appears in the control region (C), no color line appears in the test region (T). The absence of a test result line indicates a positive result meaning that the albumin concentration of sample is elevated (≥20ug/ml).

 

INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the diagnostic test immediately and contact your local distributor.

 

Order Information

 

Cat. No.ProductSpecimenPack
OMIA-101Micro-Albumin Semi-Quantitative Rapid Test DipstickUrine50 T
OMIA-102Micro-Albumin Semi-Quantitative Rapid Test CassetteUrine25 T
OMAL-101Micro-Albumin Qualitative Rapid Test DipstickUrine50 T
OMAL-102Micro-Albumin Qualitative Rapid Test CassetteUrine25 T

 

Hot Products

Principle Chromatographic Immunoassay Format Dipstick, Cassette Specimen Stain Certificate CE ...
Calprotectin and Lactoferrin Comb lateral flow Rapid Test Cassette in human feces CE Certificated ...
Accurate Total IgE Rapid Test with 98.6% Overall Accuracy CE Approved Principle Chromatographic ...
Principle Chromatographic Immunoassay Format Cassette Specimen S/P Certificate CE Reading Time 10 ...
Micro - Albumin Rapid Test Dipstick Qualitative Detection Microalbuminuria Product features ...
Product features Parameters Principle Chromatographic Immunoassay Format Cassette Specimen WB/S/P ...