Antenna Far-field Measurement Anechoic Chamber
 
Such anechoic chamber & related test field can fully the measurement on the radiation performance parameters, such as: Aantenna Gain, Radiation Pattern, Directivity, Axial Ratio, Half-power Beam width, Front to Back Ratio, Beam Pointing Angle, Cross-polarization Discrimination, Upper Side-Lobe Suppression, Zero-filling, Equivalent Radiation Efficiency and etc. EUT, e.g.: horn antenna, micro strip antenna, yagi uda, slot waveguide antenna and etc.
 
The test filed is a steel plate bolted anechoic chamber, with net size: 7m(L)×3m (W)×3m(H) (before the absorbers installed), and the distance between transmitting antenna and receiving antenna is 4m. Note: the size can be customized according to the users specific application and requirements.
 
① Anechoic chambe’s size: 7m(L)×3m(W)×3m(H) example size
② Working frequency: 0.5~10GHz
③ Quiet zones location: its center is 2m far from the back wall,and in the middle between up and down, left and right wall.
④ Quiet zones size:0.4m×0.4m×0.4m, and meet the far-field conditons
⑤ Quiet zones reflection level: 0.8~1GHz, >-25dB; 1~2GHz,>-30dB; 2~6GHz,>-35dB.
⑥ Cross polarization level ≤-25dB@1~10GHz
⑦ Shielding effectiveness: ≥80dB@0.8~10GHz
⑧ EUT (Antenna under test):
            Frequency range: 0.5~10GHz
            Antenna size: it should meet the far-field conditons
            Gross weight ≤10kg
            Test accuracy: Gain ≤ ­­­±0.5dB
             Side lobe (-10dB) ≤­­­ ±1.0dB
            3dB beamwidth measurement error ≤ ±5% of BW
            Front to back ratio accuracy < 3dB
This anechoic chamber with good ventilation, pollution-free, odor-free, can be monitored.
 

Hot Products

The anechoic chamber is mainly used to simulate free space environment for EMC testing, and it can ...
The anechoic chamber can effectively eliminate external electromagnetic interference and a variety ...
Compact Anechoic Chamber With increment of the aperture of the AUT and increasing of the antenna ...
Outdoor Antenna Far-field Measurement System 1. Overview Suchantennafar-field measurementsystemis ...
Antenna Far-field Measurement Anechoic Chamber Such anechoic chamber & related test field can fully ...
The anechoic chamber was built through carefully design and calculation, and it can provide near...