Antenna Far-field Measurement Anechoic Chamber
Such anechoic chamber & related test field can fully the
measurement on the radiation performance parameters, such as:
Aantenna Gain, Radiation Pattern, Directivity, Axial Ratio,
Half-power Beam width, Front to Back Ratio, Beam Pointing Angle,
Cross-polarization Discrimination, Upper Side-Lobe Suppression,
Zero-filling, Equivalent Radiation Efficiency and etc. EUT, e.g.:
horn antenna, micro strip antenna, yagi uda, slot waveguide antenna
and etc.
The test filed is a steel plate bolted anechoic chamber, with net
size: 7m(L)×3m (W)×3m(H) (before the absorbers installed), and the
distance between transmitting antenna and receiving antenna is 4m.
Note: the size can be customized according to the users specific
application and requirements.
① Anechoic chambe’s size: 7m(L)×3m(W)×3m(H) example size
② Working frequency: 0.5~10GHz
③ Quiet zones location: its center is 2m far from the back wall,and
in the middle between up and down, left and right wall.
④ Quiet zones size:0.4m×0.4m×0.4m, and meet the far-field conditons
⑤ Quiet zones reflection level: 0.8~1GHz, >-25dB;
1~2GHz,>-30dB; 2~6GHz,>-35dB.
⑥ Cross polarization level ≤-25dB@1~10GHz
⑦ Shielding effectiveness: ≥80dB@0.8~10GHz
⑧ EUT (Antenna under test):
Frequency range:
0.5~10GHz
Antenna size: it should
meet the far-field conditons
Gross weight ≤10kg
Test accuracy: Gain ≤
±0.5dB
Side lobe (-10dB)
≤ ±1.0dB
3dB beamwidth measurement
error ≤ ±5% of BW
Front to back ratio
accuracy < 3dB
This anechoic chamber with good ventilation, pollution-free,
odor-free, can be monitored.