Specifications for 1000KW Marine Type Brushless Generator for Ship/ Boat

1. Directly Manufacturer
2. 100% Copper wire AC Alternator 1250KVA/1000KW
3. OEM Service
4. CE/ISO/CCS Approved
5. 30 days lead time

 

FARADAY 100% Copper Wire Marine Type Three Phase AC Alternator 30KW-1000KW

Alternator Features:

- Brushless, Synchronous AC Alternator, Easy operation and simple maintenance

- IP23, Insulation Class H Alternator

- Usage: As a electric power source matching diesel engines for lighting purpose in Town, Countryside, Work sites, Mountain and Pasture lands

- Drip-proof type

- 3 phase 4 wire type, Star connection

- 50HZ, 380V, 1500RPM as standard, also 60HZ can be made as customers’ requirement

- Certificate: CE/ISO9001

Operating conditions

Under the following environment, The generator could be continuous and rated running:
Above sea level: Not exceed 1000m
Cooling air temperature: 258~313K(-15 ℃~ 40 ℃)
Relative air damping: not exceed 90%

Alternator Specification:

3-PH, 50HZ@1000RPM, 400/230V(Also can be made according to customers’ special requirements)

Alternator Model

FDM6E2-4

Power

1250kva / 1000kw

Exciter type

Brushless, Self excitation system

Power factor

0.8

Voltage adjust range

≥3%

Voltage regulation NL-FL

≤±0.3%

Insulation Grade

H

Protection Grade

IP23

FARADAY FD7 Series Alternator data for your reference:

 

Marine Type Three Phase AC Brushless Alternator
Alternator ModelRated Power KVARated Voltage
(V)
Rated Current (A)Rated Speed
(r/min)
Power factorEfficiency
(%)
Phase
50Hz60Hz50Hz60Hz50Hz60Hz50Hz60Hz50Hz60Hz
FDM2A-437.5454004505458150018000.882.784.03
FDM2C-450554004507271150018000.886.187.43
FDM2DS-462.5704004509090150018000.889.089.93
FDM3A-48090400450115115150018000.888.589.33
FDM3C-494105400450136135150018000.890.491.33
FDM3DS-4112.5130400450162167150018000.890.791.33
FDM3D-4125140400450180180150018000.891.291.83
FDM3EM-4150170400450217218150018000.892.292.83
FDM3G-4187.5220400450271282150018000.892.793.23
FDM3H-4225270400450325346150018000.892.593.03
FDM4MS-4250290400450361372150018000.892.993.33
FDM4M-4312.5350400450451449150018000.893.393.83
FDM4LP-4375430400450541552150018000.893.794.13
FDM5S-4400460400450577590150018000.894.094.33
FDM5MP-4450500400450650641150018000.894.594.83
FDM5LS-4500570400450722731150018000.894.895.03
FDM5L-4575640400450830821150018000.894.795.03
FDM5LP-4625680400450902872150018000.895.095.23
FDM6A-470080040045010101026150018000.894.594.73
FDM6B-4787.592040045011371180150018000.894.794.93
FDM6C-4887.5100040045012811283150018000.895.095.23
FDM6D-41000110040045014431411150018000.895.495.53

 

Product Show

 

Package Details

Warranty Period

- Within 24 months from alternator's delivery or 18 months after the date first used, whichever comes first.

- During the guarantee period, we will supply freely service of the easy damaged parts for the possible problems except for the incorrect operation.

- After expiration, you should pay for the spare parts cost for alternator maintenance.

Payment Terms

- 30% deposit(T/T),balance (70%) to be paid before shipment.

- 100% irrevocable L/C at sight.

Why Choose Us?

1) factory photos. Welcome to visit our factory!

- Over 12 years experience in generator field

- Directly manufacturer

2) Production Process

  • R & D Ability
  • High voltage generator

  • 6 pole and 8 pole ac generator

New photos will come soon!

  • Marine generator

Main Partners

How to choose us?

1.Classification of generator:

(1) single phase or three phase;

(2) single bearing or double bearing;

(3) PMG is optional (except for FD1 series)

(4) Droop Kit and Anti-condensation heater are optional according to the operation environment.

(5) 2 pole/ 4 pole/ 6 pole/ 8 pole alternators are optional

2.How to choose AVR?

FD1/FD2 series SX460

FD3/FD4/FD5 series SX440

FD6 SX321 / PMG

FD7 SX341 / PMG

3.How to select generator?

-- working environment (less than 1000m above sea level & less than 40 ℃ ambient temperature)

-- different country with different frequency (60HZ for Korea, Taiwan, Philippines, Saudi Arabia, North America and South America countries)

-- For sea side operating environment, anti-condensation heater and droop CT

-- Insulation class H generator

-- 2/3 pitch

-- silicon steel, 100% copper wire, VPI system with Elantas Epoxy insulation painting

4. What is FD and FDH?

--FD means Faraday low voltage alternator

--FDH means Faraday high voltage alternator

--The model instruction is as follows:

 

 

 

 

 

 

 

 

 

 

 

Hot Products

Specifications for 120KW Marine Type Brushless Generator for Ship/ Boat 1. Directly Manufacturer 2. ...
Specifications for Marine Generator with CCS class Certificate 30KW to 800KW 1. Directly Manufacture...
Specifications for 150KVA Brushless Single Bearing AC Alternator for Marine Using 1. Directly ...
Specifications for Synchronous Altenrator Three Phase Output AC Generator for Marine Auxiliary ...
Specifications for 1000KW Marine Type Brushless Generator for Ship/ Boat 1. Directly Manufacturer 2. ...
Specifications for low rpm alternator 6 pole generator 1000rpm/ 1200rpm alternator manufacturer 1. ...