RG6 T60 CCST Technical Specification |
OBJECT | Coaxial Cable | Brand | |
GRADE | RG6 Tri |
TEST ITEMS | UNIT | LIMITS | Material |
Conductor | mm | 1.02±0.02 | Copper Cover Steel |
Dielectric | Thickness | 1.775±0.065 | Foam polyethylene |
Diameter | 4.57±0.13 | |
AL Tape | 0.05 | Aluminum/Poly tapeBonded |
Outer conductor | Braiding Coverage | 0.12±0.005 x80 wire H=32mmCoverage 57% | 0.12mmAluminum |
AL TAPE | 0.05 | Aluminum/Poly tape /Aluminum Nonbonded |
Jacket wall thickness | 0.76±0.15 | (White or Black), ROHS and CPR E flame retardant PVC |
Diameter Over Jacket | 7.0±0.2 | |
Attenuation(1000MHz, 20℃) | dB/100m NetworkAnalyzer | 5MHZ | 2.70dB | |
55MHz | 5.25 dB↓ | |
211 MHz | 10.0 dB↓ | |
270 MHz | 11.0 dB↓ | |
300 MHz | 11.6 dB↓ | |
330 MHz | 12.3 dB↓ | |
400 MHz | 13.6 dB↓ | |
450 MHz | 14.4 dB↓ | |
550 MHz | 16.2 dB↓ | |
750 MHz | 19.0 dB↓ | |
870 MHz | 20.6 dB↓ | |
1000 MHz | 21.49 dB↓ | |
Sparker test | AVC | | 4000 | |
Inner Voltage | V | | 3000 | Conductor to shield |
Impedance | Ω | | 75+3 | |
Velocity propagation | % | | 82 | |
V.S.W.R(Return loss) | | | 1.2↓(20 dB↑) | 100% swept test |
Insulation Resistance | MΩ | | 1000↑(20℃) | |
Capacitance | pF/m | | 53 | |
Conductor & Dielectric To stick | kgf | 100mm/min | ≥4.5kgf | test sample length 5cm |
| | | | |