2V 200Ah Deep Cycle Gel Battery Rechargeable Maintenance Free
 
Description

Deep Cycle Gel Battery JGFM series is specially designed for frequent cyclic performance. With thicker plates, special nano-gelled material and additives as well as updated safety valve regulated technology, the Deep Cycle Gel Battery JGFM series has excellent performance for high/lower temperature stability and lower current/power discharge application. Besides, unique formulas ensure the battery can be recharged easily to a normal level, and offer longer service life.

 

ModelNominal VoltageCapacity C10WeightDimension
HeightLengthWidth
VAhkgmmmmmm
JGFM 100-221007.2205172102
JGFM 150-221509320172102
JGFM 200-2220013329171111
JGFM 300-2230018330171151
JGFM 400-2240025329211176
JGFM 500-2250028331241172
JGFM 600-2260035331301175
JGFM 800-2280048333410175
JGFM 1000-22100062329470175
JGFM 1500-22150096343401351
JGFM 2000-222000123343491351
JGFM 3000-223000180341712353

 


 
Product Features

  • Product name: Deep Cycle Gel Battery
  • Capacity range: 100Ah-3000Ah
  • Voltage class: 2V
  • Float charge voltage: 2.23V-2.25V
  • Equalized charge voltage: 2.35V-2.40V
  • Long working life: 10years
  • Low self-discharge rate: ≤3%/month
  • High sealed reaction efficiency: ≥99%
  • Widen operation temperature rang: -30℃~55℃
  • Corrugated plate grid and thick plate design, long float life of battery
  • Positive 4BS nucleation technology and negative electrode formula, high temperature and high humidity curing process, battery cycle Excellent performance

Advantages

  • Product name: Deep Cycle Gel Battery
  • Wide range of battery operating temperature, can be used within -15℃~+45℃, the recommended operating temperature is 25℃±5℃.
  • High reliability due to multi-alloy plate grid, special lead paste formula, high temperature and high humidity curing process of pole plate and tight assembly technology.

Application

  • Wired communication bureaus (stations), switching stations
  • Wireless communication bureaus (stations), decentralized base stations
  • Electricity, military and other types of private network communication base stations

Compliant standards

  • IEC60896-2-1995
  • TD/T 799-2010
  • GB/T 19638.2-2005
  • GB/T22473-2008
  • YD/T1360-2005
  • JISC8704-2:1999
  • Passed ISO9001.ISO14001, GB/T28001-2001, CE,
  • TLC, CGC certificate

Use of Deep Cycle Gel Battery

  • Product name: Deep Cycle Gel Battery
  • Check before charging and discharging: Before charging and discharging, the insulation of the charging equipment should be checked to see if it is good. Specific method: use 500V megohmmeter to measure the DC charging screen bus not less than 10MΩ.
  • Initial replenishment of electricity: Before putting the battery into use after installation and inspection, it should be balanced and supplemented with 14.1V balanced charging voltage at 25℃ for a single battery, and charged in a constant voltage current-limiting way for the battery pack. The maximum charging current is set to 0.25C10A.
  • Discharge: 1) 12V battery charging and discharging, 250Ah battery with a current of no more than 25A for 10 hours to discharge until the battery termination voltage of 10.8V or more, do not over discharge.

    2) During the discharge process, measure and record the battery voltage, discharge current and ambient temperature every hour, pay attention to the change of ammeter and battery voltage at any time, when the voltage drops to about 12.0V, change to half an hour test. When the measured voltage is 10.8v, stop discharging, open the discharge switch, the discharge is over. And record the discharge termination time, battery voltage, ambient temperature.

    3) After discharge, the battery should be recharged in time, to prevent acidification of the poles, the discharge-charging interval should not exceed 8 hours, so it must be balanced within 8 hours to replenish the electricity, the average charging voltage is set to 14.1V (the average of the measured value of the positive and negative terminals of the battery at 25℃), and the maximum charging current is set to 0.25C10A. The battery will run normally with the float charging voltage of 13.5V. Battery 13.5V.

    4) After discharge, check the discharge capacity at 25℃, it should be not less than 85% of the rated capacity, i.e. 12V250AH battery is not less than 212.5Ah.
  • Temperature compensation: The above current and voltage setting values are the standard values when the ambient temperature is 25℃, if the gel battery working temperature is beyond the range of 20℃-30℃, the floating charge and average charge voltage should be corrected accordingly, the corrected voltage is, that is, for every 1℃ increase in temperature, the floating charge voltage is reduced by 5.5mV, and for every 1℃ decrease in temperature, the floating charge voltage is increased by 5.5mV.

Hot Products

12V 150Ah Deep Cycle Gel Battery Energy Storage Solar System UPS Description Deep Cycle Gel Battery ...
12V 180Ah Deep Cycle Gel Battery Rechargeable Solar System Home Use Description Deep Cycle Gel ...
12V 200Ah Deep Cycle Gel Battery Full Capacity Long Service Life Description LCPC series Deep Cycle ...
12V 250Ah Deep Cycle Gel Battery Energy Storage High Performance Description Deep Cycle Gel Battery ...
2V 200Ah Deep Cycle Gel Battery Rechargeable Maintenance Free Description Deep Cycle Gel Battery ...
2V 300Ah Deep Cycle Gel Battery Energy Storage High Performance Description JGFM series Deep Cycle ...