UL Insulated FM200 Fire Suppression System With No Residue In The Telecommunications Room
 
Description of UL FM200 Fire Suppression System
Heptafluoropropane (HFC-227ea) is a clean and safe fire extinguishing agent that can be used in fully submerged automatic fire extinguishing systems, replacing Halon 1301, and maintaining the excellent fire extinguishing performance of Halon fire extinguishing agent without causing any environmental problems
 
The safety of the heptafluoropropane (HFC-227ea) fire extinguishing system in total flooding applications is safer than Halon 1301, with a safe exposure concentration of 9% accepted by the US Environmental Protection Agency (EPA). Meanwhile, the ozone depletion value (ODP) of HFC-227ea is 0, non-conductive, clean, and residue free.

 
 
Attributes of UL GB series cylinders

Model No.Nominal pressure (bar)Nominal volume(L)Filling volume (kg)

Caliber

(mm)

Weight

(kg)

Min.Max.
AG227SP-25-40M254019.244.84947
AG227SP-25-50M255024.056.04958
AG227SP-25-60M256028.867.24965
AG227SP-25-70M257033.678.44972
AG227SP-25-80M258038.489.64980
AG227SP-25-90M259043.2100.84994
AG227SP-25-100M2510048.0112.049100
AG227SP-25-120M2512057.6134.449113
AG227SP-25-150M2515072.0168.049134
AG227SP-25-40K254019.244.83341
AG227SP-25-50K255024.056.03352
AG227SP-25-60K256028.867.23359
AG227SP-42-40M424019.244.84947
AG227SP-42-50M425024.056.04958
AG227SP-42-60M426028.867.24965
AG227SP-42-70M427033.678.44972
AG227SP-42-80M428038.489.64980
AG227SP-42-90M429043.2100.84994
AG227SP-42-100M4210048.0112.049100
AG227SP-42-120M4212057.6134.449113
AG227SP-42-150M4215072.0168.049134
AG227SP-42-170M4217081.6190.449149
AG227SP-42-40K424019.244.83341
AG227SP-42-50K425024.056.03352
AG227SP-42-60K426028.867.23359

 
 
Features of UL FM200 Fire Suppression System

  • Very stable behaviour.
  • In less than 10 seconds, a fast extinguishing time with the discharge.
  • High efficiency, low extinguishing concentration
  • Applicable in occupied areas
  • Low storage pressure with low noise discharges.
  • Minimum container footprint.
  • After discharge, there is no residue.
  • Electrically unconductive, secure for use in spaces that are inhabited by humans.
  • Zero ozone depleting potential

 
Application of UL FM200 Fire Suppression System
Fire suppression system HFC-227ea can be used in normal commercial and industrial settings. Typical areas that can be protected by this system include:

  • Bank strong room
  • Libraries
  • Bookstores
  • Electronic data processing center
  • Telephone switching studio
  • Communication center
  • Transformer and switchgear room
  • Control room
  • Test lab
  • Inflammable liquid storage room

 
Packages of UL FM200 Fire Suppression System
We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.
















Hot Products

FM200 Fire Suppression System With No Contamination Of Storage Rooms Using Noncorrosive With UL ...
FM200 Enclosed Flooding Fire Extinguishing System Without Pollution For Library UL Certification ...
UL Insulated FM200 Fire Suppression System With No Residue In The Telecommunications Room Descriptio...
UL HFC227ea High-Quality Fire Suppression System Without Pollution For Museum Description of UL ...
UL Environment Friendly HFC227ea Fire Extinguisher System Without Residue In UPS Room Description of ...
UL Fire Extinguishing System Without A Residue For Anechoic Chamber Non Corrosive HFC227ea ...